{"product_id":"tr050fk","title":"TR050FK","description":"\u003cp data-end=\"328\" data-start=\"258\"\u003e\u003cstrong data-end=\"328\" data-start=\"258\"\u003eVersatile Fire Protection for Critical Small-to-Midsize Enclosures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"21\" data-end=\"94\"\u003eA fire in a small enclosure can go from “nothing” to serious damage fast.\u003c\/p\u003e\n\u003cp data-start=\"96\" data-end=\"351\"\u003eThat’s exactly why the \u003cstrong data-start=\"119\" data-end=\"139\"\u003eBlazeCut TR050FK\u003c\/strong\u003e exists. It’s built for tight spaces like printer enclosures, battery compartments, and electrical cabinets where heat can build quickly and a small fire can turn into a costly loss before you have time to react.\u003c\/p\u003e\n\u003cp data-start=\"353\" data-end=\"494\"\u003eIt mounts inside the space you want to protect and stays on guard 24\/7.\u003cbr data-start=\"424\" data-end=\"427\"\u003eThere’s \u003cstrong data-start=\"435\" data-end=\"493\"\u003eno wiring, no external power, and no complicated setup\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"496\" data-end=\"654\"\u003eWhen the temperature reaches a critical point, the tube opens at the hottest spot and releases \u003cstrong data-start=\"591\" data-end=\"616\"\u003eFK-5-1-12 clean agent\u003c\/strong\u003e directly onto the source of the fire.\u003c\/p\u003e\n\u003cp data-start=\"656\" data-end=\"776\"\u003eThat means fast suppression where the fire starts, with \u003cstrong data-start=\"712\" data-end=\"733\"\u003eno powder residue\u003c\/strong\u003e and no mess spread through your equipment.\u003c\/p\u003e\n\u003cp data-start=\"778\" data-end=\"823\"\u003eAnd for most people, that’s the bigger point.\u003c\/p\u003e\n\u003cp data-start=\"825\" data-end=\"1137\"\u003eThese enclosures are often sitting \u003cstrong data-start=\"860\" data-end=\"922\"\u003einside a home, garage, workshop, office, or equipment room\u003c\/strong\u003e. If a fire starts inside one and there’s nothing there to control it, it may not stay contained for long. The TR050FK helps address the fire at the source before it has the chance to spread to the surrounding area.\u003c\/p\u003e\n\u003ch3 data-start=\"1139\" data-end=\"1154\"\u003eCommon uses\u003c\/h3\u003e\n\u003cul data-start=\"1155\" data-end=\"1382\"\u003e\n\u003cli data-start=\"1155\" data-end=\"1178\"\u003e\n\u003cp data-start=\"1157\" data-end=\"1178\"\u003e3D printer enclosures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1179\" data-end=\"1221\"\u003e\n\u003cp data-start=\"1181\" data-end=\"1221\"\u003eSmall electrical cabinets and fuse boxes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1222\" data-end=\"1244\"\u003e\n\u003cp data-start=\"1224\" data-end=\"1244\"\u003eBattery compartments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1245\" data-end=\"1268\"\u003e\n\u003cp data-start=\"1247\" data-end=\"1268\"\u003eAV \/ network cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1269\" data-end=\"1309\"\u003e\n\u003cp data-start=\"1271\" data-end=\"1309\"\u003eATM and kiosk electronics compartments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1310\" data-end=\"1382\"\u003e\n\u003cp data-start=\"1312\" data-end=\"1382\"\u003eOther compact enclosed or semi-enclosed spaces with elevated fire risk\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1384\" data-end=\"1417\"\u003eWhy people choose the TR050FK\u003c\/h3\u003e\n\u003cul data-start=\"1418\" data-end=\"1731\"\u003e\n\u003cli data-start=\"1418\" data-end=\"1478\"\u003e\n\u003cp data-start=\"1420\" data-end=\"1478\"\u003e\u003cstrong data-start=\"1420\" data-end=\"1442\"\u003eAutomatic response\u003c\/strong\u003e when heat reaches a dangerous level\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1479\" data-end=\"1512\"\u003e\n\u003cp data-start=\"1481\" data-end=\"1512\"\u003e\u003cstrong data-start=\"1481\" data-end=\"1512\"\u003eNo power or wiring required\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1513\" data-end=\"1569\"\u003e\n\u003cp data-start=\"1515\" data-end=\"1569\"\u003e\u003cstrong data-start=\"1515\" data-end=\"1540\"\u003eClean agent discharge\u003c\/strong\u003e (no powder mess to clean up)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1570\" data-end=\"1596\"\u003e\n\u003cp data-start=\"1572\" data-end=\"1596\"\u003e\u003cstrong data-start=\"1572\" data-end=\"1596\"\u003eSafe for electronics\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1597\" data-end=\"1636\"\u003e\n\u003cp data-start=\"1599\" data-end=\"1636\"\u003e\u003cstrong data-start=\"1599\" data-end=\"1618\"\u003eEasy to install\u003c\/strong\u003e in compact spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1637\" data-end=\"1690\"\u003e\n\u003cp data-start=\"1639\" data-end=\"1690\"\u003e\u003cstrong data-start=\"1639\" data-end=\"1666\"\u003eBuilt-in pressure gauge\u003c\/strong\u003e for quick status checks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1691\" data-end=\"1731\"\u003e\n\u003cp data-start=\"1693\" data-end=\"1731\"\u003e\u003cstrong data-start=\"1693\" data-end=\"1714\"\u003eLong service life\u003c\/strong\u003e (up to 10 years)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1733\" data-end=\"1944\"\u003eIf you have a compact enclosure with electronics or batteries inside, the TR050FK is a simple way to add protection where fires often start and help reduce the risk of that fire spreading to the space around it.\u003c\/p\u003e\n\u003chr data-end=\"2231\" data-start=\"2228\"\u003e\n\u003ch3 data-end=\"2254\" data-start=\"2233\"\u003eProtection Specs:\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2533\" data-start=\"2256\"\u003e\n\u003cthead data-end=\"2324\" data-start=\"2256\"\u003e\n\u003ctr data-end=\"2324\" data-start=\"2256\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2283\" data-start=\"2256\"\u003eApplication Type\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2324\" data-start=\"2283\"\u003eProtected Volume\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2533\" data-start=\"2394\"\u003e\n\u003ctr data-end=\"2463\" data-start=\"2394\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2421\" data-start=\"2394\"\u003eElectrical Enclosures\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2463\" data-start=\"2421\"\u003e5.3 – 8.1 ft³ (0.15 – 0.23 m³)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2533\" data-start=\"2464\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2491\" data-start=\"2464\"\u003eEngine\/Fuel Compartments\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2533\" data-start=\"2491\"\u003e3.9 – 6.0 ft³ (0.11 – 0.17 m³)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"2538\" data-start=\"2535\"\u003e\n\u003ch3 data-end=\"2562\" data-start=\"2540\"\u003eTechnical Details:\u003c\/h3\u003e\n\u003cul data-end=\"2684\" data-start=\"2564\"\u003e\n\u003cli data-end=\"2596\" data-start=\"2564\"\u003e\n\u003cp data-end=\"2596\" data-start=\"2566\"\u003e\u003cstrong data-end=\"2582\" data-start=\"2566\"\u003eUnit Length:\u003c\/strong\u003e 19.7 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2642\" data-start=\"2597\"\u003e\n\u003cp data-end=\"2642\" data-start=\"2599\"\u003e\u003cstrong data-end=\"2625\" data-start=\"2599\"\u003eOperating Temperature:\u003c\/strong\u003e -4°F to +194°F\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2684\" data-start=\"2643\"\u003e\n\u003cp data-end=\"2684\" data-start=\"2645\"\u003e\u003cstrong data-end=\"2672\" data-start=\"2645\"\u003eActivation Temperature:\u003c\/strong\u003e 267°F ± 6°F\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2689\" data-start=\"2686\"\u003e\n\u003ch3 data-end=\"2726\" data-start=\"2691\"\u003eWhat Makes FK-5-1-12 Different?\u003c\/h3\u003e\n\u003cp data-end=\"3104\" data-start=\"2728\"\u003e\u003cstrong data-end=\"2741\" data-start=\"2728\"\u003eFK-5-1-12\u003c\/strong\u003e is a \u003cstrong data-end=\"2806\" data-start=\"2747\"\u003enon-toxic, non-conductive, and residue-free clean agent\u003c\/strong\u003e that’s safe for people, equipment, and enclosed spaces. It’s also one of the most \u003cstrong data-end=\"2945\" data-start=\"2889\"\u003eenvironmentally friendly fire suppressants available\u003c\/strong\u003e, with \u003cstrong data-end=\"2986\" data-start=\"2952\"\u003ezero ozone depletion potential\u003c\/strong\u003e and a \u003cstrong data-end=\"3030\" data-start=\"2993\"\u003every low global warming potential\u003c\/strong\u003e—making it a smarter, safer alternative to traditional halon-based agents.\u003c\/p\u003e","brand":"Modern Fire Suppression","offers":[{"title":"Default Title","offer_id":51651417243946,"sku":"sku-42435293151329","price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/7103\/3642\/files\/50_ac0a818a-20e1-4efe-8846-90c420c718cc.png?v=1780751755","url":"https:\/\/equipmentleader.com\/products\/tr050fk","provider":"Equipment Leader","version":"1.0","type":"link"}