{"product_id":"tr025fk","title":"TR025FK","description":"\u003cp data-end=\"456\" data-start=\"373\"\u003e\u003cstrong data-end=\"456\" data-start=\"373\"\u003eAutomatic Fire Suppression for Small Enclosures - No Power, No Mess, No Worries\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"450\" data-start=\"377\"\u003eA fire in a small enclosure can go from “nothing” to serious damage fast.\u003c\/p\u003e\n\u003cp data-end=\"707\" data-start=\"452\"\u003eThat’s exactly why the \u003cstrong data-end=\"495\" data-start=\"475\"\u003eBlazeCut TR025FK\u003c\/strong\u003e exists. It’s built for tight spaces like printer enclosures, battery compartments, and electrical cabinets where heat can build quickly and a small fire can turn into a costly loss before you have time to react.\u003c\/p\u003e\n\u003cp data-end=\"850\" data-start=\"709\"\u003eIt mounts inside the space you want to protect and stays on guard 24\/7.\u003cbr data-end=\"783\" data-start=\"780\"\u003eThere’s \u003cstrong data-end=\"849\" data-start=\"791\"\u003eno wiring, no external power, and no complicated setup\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-end=\"1010\" data-start=\"852\"\u003eWhen the temperature reaches a critical point, the tube opens at the hottest spot and releases \u003cstrong data-end=\"972\" data-start=\"947\"\u003eFK-5-1-12 clean agent\u003c\/strong\u003e directly onto the source of the fire.\u003c\/p\u003e\n\u003cp data-end=\"1132\" data-start=\"1012\"\u003eThat means fast suppression where the fire starts, with \u003cstrong data-end=\"1089\" data-start=\"1068\"\u003eno powder residue\u003c\/strong\u003e and no mess spread through your equipment.\u003c\/p\u003e\n\u003cp data-end=\"1179\" data-start=\"1134\"\u003eAnd for most people, that’s the bigger point.\u003c\/p\u003e\n\u003cp data-end=\"1494\" data-start=\"1181\"\u003eThese small enclosures are often sitting \u003cstrong data-end=\"1278\" data-start=\"1222\"\u003einside a home, garage, workshop, office, or building\u003c\/strong\u003e. If a fire starts inside one and there’s nothing there to control it, it may not stay contained for long.\u003c\/p\u003e\n\u003cp data-end=\"1494\" data-start=\"1181\"\u003eThe TR025FK helps address the fire at the source, before it has the chance to spread to the surrounding area.\u003c\/p\u003e\n\u003ch3 data-end=\"1511\" data-start=\"1496\"\u003eCommon uses\u003c\/h3\u003e\n\u003cul data-end=\"1742\" data-start=\"1512\"\u003e\n\u003cli data-end=\"1535\" data-start=\"1512\"\u003e\n\u003cp data-end=\"1535\" data-start=\"1514\"\u003e3D printer enclosures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1578\" data-start=\"1536\"\u003e\n\u003cp data-end=\"1578\" data-start=\"1538\"\u003eSmall electrical cabinets and fuse boxes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1601\" data-start=\"1579\"\u003e\n\u003cp data-end=\"1601\" data-start=\"1581\"\u003eBattery compartments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1625\" data-start=\"1602\"\u003e\n\u003cp data-end=\"1625\" data-start=\"1604\"\u003eAV \/ network cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1666\" data-start=\"1626\"\u003e\n\u003cp data-end=\"1666\" data-start=\"1628\"\u003eATM and kiosk electronics compartments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1742\" data-start=\"1667\"\u003e\n\u003cp data-end=\"1742\" data-start=\"1669\"\u003eOther small enclosed spaces (up to \u003cstrong data-end=\"1717\" data-start=\"1704\"\u003e3.5 cu ft\u003c\/strong\u003e) with elevated fire risk\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1777\" data-start=\"1744\"\u003eWhy people choose the TR025FK\u003c\/h3\u003e\n\u003cul data-end=\"2091\" data-start=\"1778\"\u003e\n\u003cli data-end=\"1838\" data-start=\"1778\"\u003e\n\u003cp data-end=\"1838\" data-start=\"1780\"\u003e\u003cstrong data-end=\"1802\" data-start=\"1780\"\u003eAutomatic response\u003c\/strong\u003e when heat reaches a dangerous level\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1872\" data-start=\"1839\"\u003e\n\u003cp data-end=\"1872\" data-start=\"1841\"\u003e\u003cstrong data-end=\"1872\" data-start=\"1841\"\u003eNo power or wiring required\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1929\" data-start=\"1873\"\u003e\n\u003cp data-end=\"1929\" data-start=\"1875\"\u003e\u003cstrong data-end=\"1900\" data-start=\"1875\"\u003eClean agent discharge\u003c\/strong\u003e (no powder mess to clean up)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1956\" data-start=\"1930\"\u003e\n\u003cp data-end=\"1956\" data-start=\"1932\"\u003e\u003cstrong data-end=\"1956\" data-start=\"1932\"\u003eSafe for electronics\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1996\" data-start=\"1957\"\u003e\n\u003cp data-end=\"1996\" data-start=\"1959\"\u003e\u003cstrong data-end=\"1978\" data-start=\"1959\"\u003eEasy to install\u003c\/strong\u003e in compact spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2050\" data-start=\"1997\"\u003e\n\u003cp data-end=\"2050\" data-start=\"1999\"\u003e\u003cstrong data-end=\"2026\" data-start=\"1999\"\u003eBuilt-in pressure gauge\u003c\/strong\u003e for quick status checks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2091\" data-start=\"2051\"\u003e\n\u003cp data-end=\"2091\" data-start=\"2053\"\u003e\u003cstrong data-end=\"2074\" data-start=\"2053\"\u003eLong service life\u003c\/strong\u003e (up to 10 years)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2304\" data-start=\"2093\"\u003eIf you have a small enclosure with electronics or batteries inside, the TR025FK is a simple way to add protection where fires often start - and help reduce the risk of that fire spreading to the space around it.\u003c\/p\u003e\n\u003chr data-end=\"2697\" data-start=\"2694\"\u003e\n\u003ch3 data-end=\"2720\" data-start=\"2699\"\u003eProtection Specs:\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2965\" data-start=\"2722\"\u003e\n\u003cthead data-end=\"2781\" data-start=\"2722\"\u003e\n\u003ctr data-end=\"2781\" data-start=\"2722\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2749\" data-start=\"2722\"\u003eApplication Type\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2781\" data-start=\"2749\"\u003eProtected Volume\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2965\" data-start=\"2842\"\u003e\n\u003ctr data-end=\"2903\" data-start=\"2842\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2869\" data-start=\"2842\"\u003eElectrical Enclosures\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2903\" data-start=\"2869\"\u003e2.5 – 3.5 ft³ (0.07 – 0.10 m³)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2965\" data-start=\"2904\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2931\" data-start=\"2904\"\u003eEngine\/Fuel Compartments\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2965\" data-start=\"2931\"\u003e1.8 – 2.8 ft³ (0.05 – 0.08 m³)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"2970\" data-start=\"2967\"\u003e\n\u003ch3 data-end=\"2994\" data-start=\"2972\"\u003eTechnical Details:\u003c\/h3\u003e\n\u003cul data-end=\"3116\" data-start=\"2996\"\u003e\n\u003cli data-end=\"3028\" data-start=\"2996\"\u003e\n\u003cp data-end=\"3028\" data-start=\"2998\"\u003e\u003cstrong data-end=\"3014\" data-start=\"2998\"\u003eUnit Length:\u003c\/strong\u003e 11 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3074\" data-start=\"3029\"\u003e\n\u003cp data-end=\"3074\" data-start=\"3031\"\u003e\u003cstrong data-end=\"3057\" data-start=\"3031\"\u003eOperating Temperature:\u003c\/strong\u003e -4°F to +194°F\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3116\" data-start=\"3075\"\u003e\n\u003cp data-end=\"3116\" data-start=\"3077\"\u003e\u003cstrong data-end=\"3104\" data-start=\"3077\"\u003eActivation Temperature:\u003c\/strong\u003e 267°F ± 6°F\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1263\" data-start=\"1228\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3 data-end=\"1263\" data-start=\"1228\"\u003eWhat Makes FK-5-1-12 Different?\u003c\/h3\u003e\n\u003cp data-end=\"1641\" data-start=\"1265\"\u003e\u003cstrong data-end=\"1278\" data-start=\"1265\"\u003eFK-5-1-12\u003c\/strong\u003e is a \u003cstrong data-end=\"1343\" data-start=\"1284\"\u003enon-toxic, non-conductive, and residue-free clean agent\u003c\/strong\u003e that’s safe for people, equipment, and enclosed spaces. It’s also one of the most \u003cstrong data-end=\"1482\" data-start=\"1426\"\u003eenvironmentally friendly fire suppressants available\u003c\/strong\u003e, with \u003cstrong data-end=\"1523\" data-start=\"1489\"\u003ezero ozone depletion potential\u003c\/strong\u003e and a \u003cstrong data-end=\"1567\" data-start=\"1530\"\u003every low global warming potential\u003c\/strong\u003e—making it a smarter, safer alternative to traditional halon-based agents.\u003c\/p\u003e","brand":"Modern Fire Suppression","offers":[{"title":"Default Title","offer_id":51651416916266,"sku":"sku-42435282042977","price":170.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/7103\/3642\/files\/25_3c5684b8-2b16-4856-88be-d165e5b3e12e.png?v=1780751755","url":"https:\/\/equipmentleader.com\/products\/tr025fk","provider":"Equipment Leader","version":"1.0","type":"link"}