{"title":"Uni-Trend US","description":"\u003cp\u003e\u003cspan\u003eShop UNI-T professional testing and measurement equipment from Equipment Leader, including multimeters, oscilloscopes, electrical testers, thermal imaging tools, bench instruments, and other diagnostic equipment for technicians, contractors, engineers, and serious DIY users.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProduct selection, pricing, and availability may vary.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"ut-p21-50-mhz-1000-1-high-voltage-oscilloscope-probe","title":"UT-P21 50 MHz 1000:1 High Voltage Oscilloscope Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e40MHz (-3dB) high-voltage passive probe (1000:1 attenuation) for measuring power supply rails, inverters, and high-voltage circuits up to several kV. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e40MHz (-3dB) Bandwidth\u003c\/strong\u003e — Captures signal content up to 40MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1000:1 Attenuation\u003c\/strong\u003e — Attenuation ratio suited to the probe measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC 15kVrms\/AC 10kV Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eΦ80mm×340mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C - 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC 10 kV \/ AC 7kVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 8.8ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompensation Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 pF-50 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-P21_User_Manual.pdf\"\u003eUT-P21 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275018498346,"sku":"190500300013","price":430.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/7103\/3642\/files\/UT-P21_1_sq.jpg?v=1787007139"},{"product_id":"ut-p36-100-mhz-200-1-500-1-differential-oscilloscope-probe","title":"UT-P36 100 MHz 200:1\/500:1 Differential Oscilloscope Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e100 MHz differential oscilloscope probe (200:1\/500:1 attenuation) for safely measuring floating voltages across motor drives, power converters, and bridge circuits. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100MHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 100MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200:1\/500:1 Attenuation\u003c\/strong\u003e — Attenuation ratio suited to the probe measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e560VDC+PeackAC \/ 5600VDC+Peak AC, Accuracy: 2% Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAT Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT I 2800 V \/ CAT II 1400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 °C - 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200:1, 2000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5600Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30cm input \/ 90cm output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1.5mVrms (1\/200); ≤ 1mVrms (1\/2000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDifferential Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5600Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2800Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 80 dB DC, ≥ 60 dB 100 Hz, ≥ 50 dB 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-P35_UT-P36_User_Manual.pdf\"\u003eUT-P36 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275018400042,"sku":"190500100122X","price":459.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/7103\/3642\/files\/UT-P36_1_sq.jpg?v=1787007139"},{"product_id":"utx325-long-distance-thermal-monocular","title":"UTx325 Long-Distance Thermal Monocular","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003ch3 data-pm-slice=\"1 3 []\"\u003e\u003cspan\u003e\u003cstrong\u003eUNI-T UTx325\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan\u003eLong-Range Thermal Detection Made Simple\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eFor those requiring reliable long-range thermal detection, the UNI-T UTx325 delivers exceptional performance with simplicity and efficiency. Its long battery life and high thermal sensitivity make it an excellent choice for field professionals and outdoor enthusiasts.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe UNI-T UTx325 features a 25mm lens for long-range detection, paired with a thermal sensitivity of ≤35mK to capture subtle heat variations. Its LCOS display provides clear and bright visuals, ensuring an optimal viewing experience without adding bulk to the device.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe fixed rechargeable battery supports extended operational hours, making the UTx325 ideal for long-term use in field conditions. While it lacks range-finding capabilities and Wi-Fi, it excels in delivering dependable thermal imaging for applications such as wildlife tracking, search and rescue, and security patrols.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: LCOS for bright and clear visuals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIR Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: 384×288 pixels for detailed imaging\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLens Focal Length\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: 25mm for superior long-range detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eThermal Sensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: ≤35mK for detecting subtle temperature variations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eField of View (FOV)\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: 10.5° × 7.9° for precise scanning\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRange Finding\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: None\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: Extended fixed rechargeable battery for prolonged use\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurability\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: IP67 waterproof and drop-resistant up to 2 meters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAdditional Features\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: Hot Trace\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the detection range of the UTx325?\u003c\/p\u003e\n\u003cp\u003eDetection range depends on the target size and thermal contrast. The UTx325's specifications list the maximum detection range for a standard 1.7m × 0.5m target. Actual usable range for identification is typically 30-50% of the maximum detection distance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the UTx325 waterproof?\u003c\/p\u003e\n\u003cp\u003eThe UTx325 carries an IP rating for dust and water resistance. Check the specifications tab for the exact IP rating. The device is designed for outdoor use in varying weather conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's included with the UTx325?\u003c\/p\u003e\n\u003cp\u003eThe UTx325 ships with the monocular, carrying case, USB charging cable, lens cloth, and user manual. Check the specifications tab for the complete package contents.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Thermal%20Camera%20Datasheets\/UTx313%26318%26325%20Data%20Sheet.pdf\"\u003eUTx325 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Thermal%20Camera%20User%20Manuals\/UTx313_UTx318_UTx325_User_Manual.pdf\"\u003eUTx325 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"180700300005X","offer_id":52275018367274,"sku":"180700300005X","price":1999.0,"currency_code":"USD","in_stock":true}]},{"product_id":"ut-ck01-utility-kit","title":"UT-CK01 Utility Kit","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eConnector and cable kit for integrating UNI-T spectrum analyzers into RF test setups. Includes commonly needed adapters and interconnects.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with UNI-T spectrum analyzers\u003c\/strong\u003e — For use with UNI-T spectrum analyzers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e — Spectrum Utility Kit: includes NSMAJ-NJ-0.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC - 6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUT-W01-6 GHz, UT-W02-6 GHz, UT-C01-6 GHz (×2), UT-C02-6 GHz (×2), UTS-T01 antenna (×2), UTS-T02 antenna (×2), UTS-BAG01 pouch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-CK01-DataSheet.pdf\"\u003eUT-CK01 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275018432810,"sku":"191700100004X","price":262.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/7103\/3642\/files\/UTS-CK01_sq.jpg?v=1787007139"},{"product_id":"ut-isot-isolation-transformer","title":"UT-ISOT Isolation Transformer","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eUT-ISOT Isolation Transformer. Used for Bode Plot analysis. Requires scopes to have MSO2000-S-BODE or MSO3000CS-S-BODE option. For use with UNI-T oscilloscopes.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with UNI-T oscilloscopes\u003c\/strong\u003e — For use with UNI-T oscilloscopes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Injection\u003c\/strong\u003e — Provides isolated swept-sine signal injection for safe Bode plot measurements on live power supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired for Bode Plot Option\u003c\/strong\u003e — Used with the MSO2000-S-BODE or MSO3000CS-S-BODE Bode plot software option.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-ISOT_DataSheet.pdf\"\u003eUT-ISOT Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275018563882,"sku":"191000100022X","price":332.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/7103\/3642\/files\/UT-ISOT_1_sq.jpg?v=1787007140"},{"product_id":"udp3303c-3ch-195w-30v-3a-programmable-linear-dc-power-supply","title":"UDP3303C 3Ch 195W 30V\/3A Programmable Linear DC Power Supply","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UDP3303C is the SCPI-programmable counterpart to the UDP3303A — same 195W three-channel linear hardware, same CH3 logic-rail selector cycling 1.8V \/ 2.5V \/ 3.3V \/ 5V at 3.2A, same ≤1 mVrms ripple — with a back-panel USB-Device port and RS-232 added for full SCPI control. CH1 and CH2 deliver 0–30V at 0–3A; series and parallel modes extend that to 60V or 6A.\u003c\/p\u003e\n  \u003cp\u003eProgramming accuracy holds inside ≤0.1% + 30 mV on voltage and ≤0.5% + 2 mA on current — fine enough for sleep-mode current characterization on IoT prototypes, battery-charge cut-off testing, and any automated sweep that needs the setpoint to land exactly where you asked it. Five preset storage groups (M1–M5), shutdown memory, OVP \/ OCP \/ OTP per channel, and a Digital I\/O hardware ON\/OFF pin pair round out a programmable supply built for benches that have to behave the same way every time. For 5A per adjustable channel, see the UDP3305C; for the knob-only manual variant, see the UDP3303A.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Channels, 195W Total — SCPI Programmable\u003c\/strong\u003e — CH1 and CH2: 0–30V \/ 0–3A adjustable. CH3: switchable 1.8V \/ 2.5V \/ 3.3V \/ 5V at 3.2A. SCPI control over USB-Device or RS-232.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB-Device + RS-232 with SCPI\u003c\/strong\u003e — Back-panel data interfaces for PC connection. Standard accessories include both a USB cable (UT-D14) and RS-232 communication line — pick the bus your test rig already uses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming Accuracy ≤0.1% + 30 mV\u003c\/strong\u003e — Voltage programming accuracy ≤0.1% + 30 mV; current programming accuracy ≤0.5% + 2 mA. Set value matches output value across the full range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCH3 Logic-Rail Selector\u003c\/strong\u003e — Single front-panel button cycles CH3 through 1.8V \/ 2.5V \/ 3.3V \/ 5V at 3.2A. CMOS, microcontroller cores, legacy TTL, USB-class — covered without sacrificing CH1\/CH2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Topology, ≤1 mVrms Ripple\u003c\/strong\u003e — Clean DC output for low-noise analog work. Load regulation ≤0.01% + 3 mV in CV mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 mV \/ 1 mA Resolution\u003c\/strong\u003e — Four-digit voltage and current display per channel on EBTN LCD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries, Parallel, and Tracking Modes\u003c\/strong\u003e — Combine CH1+CH2 for up to 60V series or 6A parallel from the front panel. SCPI exposes the same modes for automated test integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOVP \/ OCP \/ OTP Protection\u003c\/strong\u003e — Configurable per-channel thresholds, plus over-temperature shutdown and keypad lock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFive Preset Storage Groups\u003c\/strong\u003e — M1–M5 store full instrument states for fast bench setup. Shutdown memory restores last settings on power-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront-Panel 5V\/2A USB Charging Port (CH4)\u003c\/strong\u003e — Independent 5V\/2A USB-A charging output. Charging output only — the data interfaces are USB-Device and RS-232 on the back panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Output Disable via Digital I\/O\u003c\/strong\u003e — Two-pin Digital I\/O terminal for emergency cutoff and external interlock circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eCH3 Logic-Rail Selector — One Button, Four Voltages\u003c\/h3\u003e\n\u003cp\u003eMost three-channel bench supplies give you two adjustable channels and a fixed 5V rail you'll resent the moment you need 3.3V. The UDP3303C's CH3 cycles between 1.8V, 2.5V, 3.3V, and 5V at 3.2A — covering CMOS logic, modern microcontroller cores, legacy TTL, and USB-class devices — at a single front-panel button press. CH1 and CH2 stay free for the analog work the linear topology is genuinely good at — op-amp rails, sensor bias, charge-pump references, audio circuits — while CH3 handles whatever digital subsystem the project also needs powered. One supply, two adjustable analog rails, one switchable digital rail, all labeled, all protected, all SCPI-controllable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/udp3000-buttons.jpg\" alt=\"UNI-T UDP3303C — ch3 logic-rail selector\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUNI-T UDP3303C — ch3 logic-rail selector\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/udp3000-buttons.jpg\" alt=\"UNI-T UDP3303C — ch3 logic-rail selector\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUNI-T UDP3303C — ch3 logic-rail selector\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/udp3000_save_recall.jpg\" alt=\"UNI-T UDP3303C — scpi programmable for repeatable bench work\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUNI-T UDP3303C — scpi programmable for repeatable bench work\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eSCPI Programmable for Repeatable Bench Work\u003c\/h3\u003e\n\u003cp\u003eThe UDP3303C is the programmable counterpart to the UDP3303A — same hardware, same protection, same CH3 logic-rail selector — with a back-panel USB-Device port and RS-232 added for SCPI control. Script the rails over USB or RS-232, capture readbacks, document the run, and repeat it tomorrow morning the same way. Programming accuracy holds inside ≤0.1% + 30 mV on voltage and ≤0.5% + 2 mA on current — fine enough for IoT sleep-mode current characterization, battery-charge cut-off testing, and any sweep that needs the setpoint to land where you asked it to. Five preset storage groups (M1–M5) and a Digital I\/O hardware ON\/OFF pin pair round out a programmable supply built for benches that have to behave the same way every time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/udp3000_save_recall.jpg\" alt=\"UNI-T UDP3303C — scpi programmable for repeatable bench work\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUNI-T UDP3303C — scpi programmable for repeatable bench work\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cdiv class=\"product-app-grid\"\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eR\u0026amp;D Bench \u0026amp; Prototyping\u003c\/h3\u003e\n\u003cp\u003eThree rails (two adjustable, one switchable digital) with SCPI control script the bench setup directly from your test framework. Linear topology and ≤1 mVrms ripple keep supply noise out of measurement on op-amp characterization, ADC reference rails, and sensor-bridge excitation work.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eAutomated Test Lab Integration\u003c\/h3\u003e\n\u003cp\u003eSCPI over USB-Device or RS-232 integrates with LabVIEW, Python-VISA, and shell-driven test frameworks. Five preset storage groups keep frequently used test setups one command away. Programming accuracy ≤0.1% + 30 mV keeps automated sweeps repeatable across runs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eTeaching Labs \u0026amp; Automated Lab Exercises\u003c\/h3\u003e\n\u003cp\u003eFor curricula that introduce instrument automation alongside instrument operation, the UDP3303C lets a class go from manual front-panel work to scripted SCPI control without changing the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eMixed-Signal Development\u003c\/h3\u003e\n\u003cp\u003eCH1 and CH2 power analog rails at low ripple; CH3 cycles through digital-side voltages without retuning. SCPI lets the test script raise or lower the digital rail while CH1\/CH2 hold the analog supplies steady — useful for power-sequencing and sleep-mode characterization on mixed-signal prototypes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's the difference between the UDP3303A and the UDP3303C?\u003c\/p\u003e\n\u003cp\u003eThe UDP3303C adds SCPI programmability over USB-Device and RS-232. Hardware (channels, voltage, current, power, CH3 logic-rail selector, protection, display, dimensions) is otherwise identical. Choose the UDP3303A if your bench is knob-only; choose the UDP3303C if you need automated test integration. For 5A per adjustable channel instead of 3A, step up to the UDP3305C.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes the UDP3303C have LAN?\u003c\/p\u003e\n\u003cp\u003eNo. The UDP3303C's data interfaces are USB-Device (back-panel SCPI port for PC connection) and RS-232. If your workflow needs LAN with LXI\/web interface, the UDP3000S series adds it on the same linear-PSU platform. The Digital I\/O pin pair on the back panel handles hardware ON\/OFF — useful for external interlocks but not for data communication.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the front-panel USB port for?\u003c\/p\u003e\n\u003cp\u003eIt's a 5V\/2A USB-A charging output (CH4) — for charging a phone or powering a USB-powered demo board. It is explicitly not a data interface. The SCPI data ports are on the back panel: USB-Device and RS-232.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan the UDP3303C run automated voltage\/current sweeps?\u003c\/p\u003e\n\u003cp\u003eYes — SCPI control over USB-Device or RS-232 supports remote voltage and current setpoint commands plus readbacks, and the five preset storage groups (M1–M5) keep frequently used configurations available for fast recall. For complex programmable waveform output (list\/delayer functions), the UDP3000S series adds those capabilities on the same linear platform.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhy a linear supply instead of switching for SCPI work?\u003c\/p\u003e\n\u003cp\u003eLinear topology produces fundamentally cleaner output — no switching frequency, no harmonic spurs, ripple under 1 mVrms. SCPI control gives you automation; linear regulation keeps the output clean enough for the precision measurements that automated test usually exists to take in the first place. The trade-off is lower efficiency and more heat, which at 195W bench-supply scale is not a meaningful constraint.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's included with the UDP3303C?\u003c\/p\u003e\n\u003cp\u003eThe UDP3303C ships with the instrument, power cord, USB communication cable (UT-D14), RS-232 communication line, alligator clip test leads, English user manual Ships from authorized US dealer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUDP3303C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 programmable (CH1, CH2 adjustable; CH3 selectable) + CH4 USB charging output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH1, CH2 Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–30V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH1, CH2 Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH3 Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8V \/ 2.5V \/ 3.3V \/ 5V (±3%, fine-tunable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH3 Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e195W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH4 USB Charging Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5V \/ 2A (front-panel USB charging output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Regulation (CV)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.01% + 3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Regulation (CC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.2% + 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming Accuracy (Voltage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.1% + 30 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming Accuracy (Current)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.5% + 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple \u0026amp; Noise (Voltage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1 mVrms (20Hz–20MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple \u0026amp; Noise (Current)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤3 mArms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤300 ppm\/°C (V\/I)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries Mode (CH1+CH2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 60V (CH1+CH2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParallel Mode (CH1+CH2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 6A (CH1+CH2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEBTN LCD, 4-digit voltage + current per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — SCPI over USB-Device or RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Device, RS-232, Digital I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 preset storage groups (M1–M5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOVP, OCP (per-channel, configurable), OTP, keypad lock, shutdown memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 \/ 120 \/ 220 \/ 230V ±10%, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 × 168 × 347 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=34\"\u003eUDP3303C Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275018596650,"sku":"181730080304X","price":365.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/7103\/3642\/files\/UDP3303C_Cables.jpg?v=1787007140"},{"product_id":"ut-p35-50-mhz-50-1-500-1-differential-oscilloscope-probe","title":"UT-P35 50 MHz 50:1\/500:1 Differential Oscilloscope Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e50 MHz differential oscilloscope probe (50:1\/500:1 attenuation) for safely measuring floating voltages across motor drives, power converters, and bridge circuits. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e50MHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 50MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e50:1\/500:1 Attenuation\u003c\/strong\u003e — Attenuation ratio suited to the probe measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e130VDC+PeackAC \/ 1300VDC+Peak AC, Accuracy: 2% Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAT Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT I 1000 V \/ CAT II 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 °C - 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50:1, 500:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1300Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60cm input \/ 90cm output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1.5mVrms (1\/50); ≤ 1mVrms (1\/500)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDifferential Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1300Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 80 dB DC, ≥ 60 dB 100 Hz, ≥ 50 dB 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-P35_UT-P36_User_Manual.pdf\"\u003eUT-P35 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275018465578,"sku":"190500100119X","price":395.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/7103\/3642\/files\/UT-P35_1_sq.jpg?v=1787007139"},{"product_id":"ut-p40-dc-100-khz-60a-ac-dc-current-probe","title":"UT-P40 DC-100 kHz 60A AC\/DC Current Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e100kHz bandwidth, 60A AC\/DC current probe for oscilloscopes. Measures current waveforms non-invasively in power electronics, motor drives, and switch-mode circuits. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Invasive Measurement\u003c\/strong\u003e — Clamp-on design requires no circuit interruption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBNC Connection\u003c\/strong\u003e — Standard BNC connector for direct connection to UNI-T oscilloscopes and other oscilloscopes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAT Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e231 × 67 × 36 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C - 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 mV\/A \/ 50 mV\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% ±0.4 A (50 mV\/A range); ±2% ±1 A (5 mV\/A range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2mVpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-P40_User_Manual.pdf\"\u003eUT-P40 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275018334506,"sku":"190500300029X","price":452.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/7103\/3642\/files\/UT-P40_1_sq.jpg?v=1787007139"},{"product_id":"ut-m15-logic-pod-for-upo-mso-oscillosocopes","title":"UT-M15 Logic Pod for UPO\/MSO Oscillosocopes","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e16-channel logic analyzer probe pod for UPO\/MSO Oscillosocopes. Adds digital bus visibility for mixed-signal debugging of embedded, automotive, and industrial protocols. Connects to compatible UNI-T oscilloscopes via the dedicated logic analyzer port.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Connects to compatible UNI-T oscilloscopes via the dedicated logic analyzer port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Channels\u003c\/strong\u003e — Adds digital bus visibility for debugging embedded, automotive, and industrial communication protocols.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e — Compatible with UNI-T MSO\/UPO2000, MSO2000X, MSO\/UPO3000, MSO3000X, MSO3000HD, MSO5000D, MSO8000HD.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8×2 square pin, 2.54mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.0 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e101 Ω ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin Pulse Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800ps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275018531114,"sku":"191000100020X","price":332.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/7103\/3642\/files\/UT-M15_sq.jpg?v=1787007139"},{"product_id":"ut-m14-amplifier","title":"UT-M14 Amplifier","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eUT-M14 Amplifier. Boost your output from your UNI-Trend UTG-Series signal generator.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with UTG waveform generators\u003c\/strong\u003e — For use with UTG waveform generators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Amplification\u003c\/strong\u003e — Boosts output signal amplitude from UTG-series waveform generators for driving higher-power loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-M14_User_Manual.pdf\"\u003eUT-M14 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275018629418,"sku":"191000200005X","price":289.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/7103\/3642\/files\/UT-M14_1_sq.jpg?v=1787007139"},{"product_id":"ut-p30-100-mhz-10-1-100-1-differential-oscilloscope-probe","title":"UT-P30 100 MHz 10:1\/100:1 Differential Oscilloscope Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e100 MHz differential oscilloscope probe (10:1\/100:1 attenuation) for safely measuring floating voltages across motor drives, power converters, and bridge circuits. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100MHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 100MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10:1\/100:1 Attenuation\u003c\/strong\u003e — Divides the input signal for measuring higher-voltage circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e800Vpp Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAT Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69 × 26 × 165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10:1, 100:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 MΩ \/ 1.3 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDifferential Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5kVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80 dB @ 60 Hz, \u0026gt; 60 dB @ 100 Hz, \u0026gt; 50 dB @ 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-P30_User_Manual.pdf\"\u003eUT-P30 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275018662186,"sku":"190500300014","price":399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/7103\/3642\/files\/UT-P30_1_sq.jpg?v=1787007140"},{"product_id":"ut8804e-4-8-digit-advanced-series-bench-digital-multimeter","title":"UT8804E 4.8 Digit Advanced-Series Bench Digital Multimeter","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UT8804E Advanced-Series Bench Digital Multimeter\u003c\/strong\u003e is a \u003cstrong\u003e4⅚-digit auto-ranging\u003c\/strong\u003e True-RMS meter with \u003cstrong\u003e0.025% basic DC voltage accuracy\u003c\/strong\u003e, a \u003cstrong\u003e59,999-count\u003c\/strong\u003e display, and a \u003cstrong\u003e4.3in TFT-LCD\u003c\/strong\u003e with digitized analog bar graph. Data recording, statistical analysis, trend-chart visualization, and Pass\/Fail batch comparison are built in.\u003c\/p\u003e\n\u003cp\u003eFor R\u0026amp;D bench validation, burn-in monitoring, and small-batch quality control where a basic 4½-digit meter lacks the recording-and-statistics workflow but a 6½-digit unit would be overkill, the UT8804E delivers measurement, logging, and analysis in one instrument. Thermocouple temperature measurement, multiple parameters per measurement function, and USB-Device PC connectivity are standard.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4⅚-digit, 59,999-count display\u003c\/strong\u003e — 0.025% basic DC voltage accuracy at the tier price point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS AC measurement\u003c\/strong\u003e — accurate readings on non-sinusoidal waveforms (switching supplies, motor drives, PWM, dimmed loads).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-ranging\u003c\/strong\u003e — across voltage, current, resistance, and capacitance functions, reducing operator workflow friction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouple temperature measurement\u003c\/strong\u003e — range -40°C to 1000°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData recording with statistics and trend-chart display\u003c\/strong\u003e — Pass\/Fail comparison for batch device testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB-Device PC connection\u003c\/strong\u003e — included software for historical-data viewing and trend monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UT8804E Details\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e4⅚-Digit Display and 0.025% Accuracy\u003c\/h3\u003e\n\u003cp\u003eThe UT8804E delivers a \u003cstrong\u003e4⅚-digit 59,999-count\u003c\/strong\u003e display with \u003cstrong\u003e0.025% basic DC voltage accuracy\u003c\/strong\u003e. DC voltage resolution is \u003cstrong\u003e0.001 mV\u003c\/strong\u003e and DC current resolution is \u003cstrong\u003e0.01μA\u003c\/strong\u003e — covering the precision needed for component validation, prototype bring-up, and general bench measurement. Resistance resolution is \u003cstrong\u003e0.01Ω\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Counts.png\" alt=\"59,999-count high-resolution 4⅚-digit display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e59,999-count high-resolution 4⅚-digit display\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Counts.png\" alt=\"59,999-count high-resolution 4⅚-digit display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e59,999-count high-resolution 4⅚-digit display\u003c\/span\u003e\n\n\u003ch3\u003eMeasurement Function Coverage\u003c\/h3\u003e\n\u003cp\u003eMeasurement coverage includes AC\/DC voltage, AC\/DC current, resistance, capacitance, diode, continuity, frequency, duty cycle, temperature (thermocouple). Capacitance measurement extends to \u003cstrong\u003e60 mF\u003c\/strong\u003e. Frequency counter range is \u003cstrong\u003e60 Hz – 60 MHz\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTrue-RMS AC Measurement\u003c\/h3\u003e\n\u003cp\u003eTrue-RMS AC measurement delivers correct readings on distorted, non-sinusoidal waveforms — switching-mode power supply outputs, motor-drive currents, dimmed lighting loads, PWM signals — where an average-responding meter would read low. AC voltage and AC current measurements are both True-RMS.\u003c\/p\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Recording.png\" alt=\"Data recording with statistics and trend chart display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eData recording with statistics and trend chart display\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eData Recording and Trend Analysis\u003c\/h3\u003e\n\u003cp\u003eData recording captures historical measurements with real-time access to the current sample count, recording duration, extreme values, and averages. Recorded data renders as both statistical summary and trend chart; the cursor on the trend chart returns the value at a specific time point, useful for isolating anomalies in time-varying signals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Recording.png\" alt=\"Data recording with statistics and trend chart display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eData recording with statistics and trend chart display\u003c\/span\u003e\n\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eMultiple Parameters per Measurement Function\u003c\/h3\u003e\n\u003cp\u003eFor each measurement function, the UT8804E exposes multiple parameter selections — for example, capacitance measurement can also display dissipation factor (D) or quality factor (Q) as a secondary parameter. The dual-parameter readout reduces function-key presses on multi-step measurement tasks and keeps both values visible during recording.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Multi.png\" alt=\"Multiple parameter selection within a single measurement function\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eMultiple parameter selection within a single measurement function\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Multi.png\" alt=\"Multiple parameter selection within a single measurement function\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eMultiple parameter selection within a single measurement function\u003c\/span\u003e\n\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Pass.png\" alt=\"Pass\/Fail comparison function for batch device testing\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003ePass\/Fail comparison function for batch device testing\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003ePass\/Fail Comparison for Batch Testing\u003c\/h3\u003e\n\u003cp\u003ePass\/Fail comparison sets a tolerance window around an expected value; readings outside the window trigger an audible alarm and a visual indicator. For batch production-test work — incoming component inspection, finished-board QC, post-burn-in verification — Pass\/Fail flagging removes the operator-attention burden of reading the numeric display on every part.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Pass.png\" alt=\"Pass\/Fail comparison function for batch device testing\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003ePass\/Fail comparison function for batch device testing\u003c\/span\u003e\n\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eMax \/ Min \/ Average Statistics with Timestamps\u003c\/h3\u003e\n\u003cp\u003eMaximum, minimum, and average value statistics track measurement extremes across a batch or time window. Each extreme reading is timestamped, so the trend chart cursor can return both the value and the moment it occurred — useful for isolating intermittent events in long-running tests.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Statistics.png\" alt=\"Maximum, minimum, and average statistics with timestamped extreme values\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eMaximum, minimum, and average statistics with timestamped extreme values\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Statistics.png\" alt=\"Maximum, minimum, and average statistics with timestamped extreme values\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eMaximum, minimum, and average statistics with timestamped extreme values\u003c\/span\u003e\n\n\u003ch3\u003eTemperature Measurement\u003c\/h3\u003e\n\u003cp\u003eThermocouple temperature measurement covers the range \u003cstrong\u003e-40°C to 1000°C\u003c\/strong\u003e with built-in cold-end compensation. Suitable for component-thermal-test, environmental monitoring, and process-temperature verification.\u003c\/p\u003e\n\u003ch3\u003eConnectivity and Remote Control\u003c\/h3\u003e\n\u003cp\u003eUSB-Device connection to a host PC enables real-time historical-data viewing, trend-chart display, and configuration backup through the included software. For workbench logging and remote monitoring of long-running tests where a separate data logger would be overkill, USB-Device provides the path.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D Bench Validation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4⅚-digit measurement on prototype boards, switching-supply outputs, and sensor circuits.\u003c\/li\u003e\n\u003cli\u003eData recording during burn-in or temperature-cycle testing with trend-chart visualization.\u003c\/li\u003e\n\u003cli\u003eMaximum\/minimum statistics for capturing intermittent events during long-duration tests.\u003c\/li\u003e\n\u003cli\u003eComponent-thermal monitoring via thermocouple input.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSmall-Batch Quality Control\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePass\/Fail batch acceptance testing with audible alarm on out-of-spec readings.\u003c\/li\u003e\n\u003cli\u003eStatistical summary across a production batch (max, min, average, sample count).\u003c\/li\u003e\n\u003cli\u003eMulti-parameter validation within a single measurement function via secondary parameter readout.\u003c\/li\u003e\n\u003cli\u003eUSB-Device connection to a host PC for measurement logging and historical-data review.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUniversity and Vocational Teaching Labs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMid-tier benchtop measurement instruction for second-year electronics and electrical engineering programs.\u003c\/li\u003e\n\u003cli\u003eMeasurement-fundamentals coursework covering recording, statistics, and trend visualization.\u003c\/li\u003e\n\u003cli\u003eCapstone project measurement with True-RMS AC and Pass\/Fail flagging.\u003c\/li\u003e\n\u003cli\u003eCost-effective stocking across multi-bench classroom installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003ch3\u003eIncluded with Every Unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT8804E benchtop digital multimeter\u003c\/li\u003e\n\u003cli\u003eStandard test lead set\u003c\/li\u003e\n\u003cli\u003eAC power cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eUSB-Device cable for PC connection\u003c\/li\u003e\n\u003cli\u003ePC software (included; downloadable from uni-trend.com)\u003c\/li\u003e\n\u003cli\u003eUser manual and factory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType-K thermocouple probe\u003c\/strong\u003e — for temperature measurement across the supported range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8802E\u003c\/strong\u003e — Value-tier 4½-digit manual-range bench DMM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8803E\u003c\/strong\u003e — Classic-tier 3⅚-digit auto-ranging bench DMM with inductance and D\/Q.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8804E\u003c\/strong\u003e — Advanced-tier 4⅚-digit bench DMM with data recording and Pass\/Fail. \u003cem\u003e(this product)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8805E\u003c\/strong\u003e — Performance-tier 5½-digit SCPI bench DMM with four-wire resistance and math.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8806E\u003c\/strong\u003e — Performance-tier 6½-digit SCPI bench DMM (LAN\/RS-232\/USB).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8806EG\u003c\/strong\u003e — Performance-tier 6½-digit bench DMM with IEEE-488.2 GPIB (substitutes for RS-232).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow does the UT8804E compare to other models in the UT8800E series?\u003c\/p\u003e\n\u003cp\u003eThe UT8804E is the mid-tier Advanced model: 4⅚-digit precision with True-RMS, auto-ranging, a 4.3-inch TFT-LCD, data recording with trend-chart display, and Pass\/Fail batch comparison. It sits between the Classic UT8803E and the Performance-cohort UT8805E. If your work needs SCPI automation, fast reading rates, or four-wire resistance, step up to UT8805E or UT8806E.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I connect the UT8804E to a PC for data logging?\u003c\/p\u003e\n\u003cp\u003eYes. The USB-Device port connects the UT8804E to a host PC running the included software, which provides real-time historical-data viewing, trend-chart display, and configuration backup. The software is included free of charge; firmware updates over the product's lifetime are free.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the UT8804E factory-calibrated, and how often does it need recalibration?\u003c\/p\u003e\n\u003cp\u003eYes — every UT8804E ships with a factory calibration certificate. The recommended recalibration interval is once per year for metrology-traceable measurement applications. For routine workbench use where the meter is being used for relative comparisons or go\/no-go checks against known references, longer intervals are acceptable. Recalibration is performed through Uni-Trend or an accredited third-party calibration laboratory.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat probes and accessories ship with the UT8804E?\u003c\/p\u003e\n\u003cp\u003eThe UT8804E ships with the standard probe and lead set appropriate to its measurement range, a power cord, the USB-Device cable for PC connection, the included software disc or download link, a user manual, and the factory calibration certificate. Verify the included contents against the packing list on delivery.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Digits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4⅚ (4.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59,999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic DC Voltage Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.025%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Voltage Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Current Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance Measurement Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Reading Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 rdgs\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrue-RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto-Ranging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance Range (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Counter Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz – 60 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Frequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMath \/ Statistics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax\/Min\/Average, Pass\/Fail, Relative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20k\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3in TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE | cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=28\"\u003eUT8804E Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n  \u003cli\u003eUT8800 series safety instructions attachment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275018694954,"sku":"180908080071X","price":269.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/7103\/3642\/files\/UT8804E_Probes.jpg?v=1787007140"},{"product_id":"uti384g-384-g-series-professional-thermal-imager","title":"UTi384G 384 G-Series Professional Thermal Imager","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UNI-T UTi384G is a handheld industrial thermal imager built around a 384×288 infrared detector with ≤40 mK thermal sensitivity and a manual focus ring. The 42° × 30° field of view, 1.91 mrad spatial resolution, and -20°C to 550°C (-4°F to 1022°F) measurement range cover the working envelope of electrical inspection, mechanical condition monitoring, building diagnostics, and solar O\u0026amp;M. IP54 sealing and a 2 m drop rating let the imager work in industrial environments without a separate protective case.\u003c\/p\u003e\n\u003cp\u003eThe 3.5″ IPS touch display (640×480) keeps menu navigation, palette selection, and on-screen analysis tools at a fingertip. A 5 MP visible camera supports thermal\/visual fusion and picture-in-picture for context. Captured images are saved as radiometric JPEGs — temperature data is embedded in every photo, so emissivity, palette, and analysis points can be edited on the imager itself or in the included free PC and mobile analysis software after the inspection is complete. The 5200 mAh detachable Li-ion (UT-M17) battery pack delivers ≈5 hours (Wi-Fi off) of operation per charge and ships in a 2-pack so a spare can stay on the charger.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eChoosing Your Model — G Pro Imager\u003c\/h2\u003e\n\u003cp\u003eThe UTi256G and UTi384G share the same chassis, detector platform (17 μm pixel pitch, 7.5–14 μm spectral response), 40 mK thermal sensitivity, 30 Hz frame rate, manual focus ring, IPS touch display, 5 MP visible camera, Wi-Fi and Bluetooth, laser pointer, LED work light, IP54\/2m sealing, and PC + mobile analysis software. The differences below are what to weigh.\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:34%\"\u003e\n\u003ccol style=\"width:33%\"\u003e\n\u003ccol style=\"width:33%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eUTi256G\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eUTi384G\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIR resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256×192\u003c\/td\u003e\n\u003ctd\u003e384×288\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of view\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28° × 20°\u003c\/td\u003e\n\u003ctd\u003e42° × 30°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-screen analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 points \/ 3 lines \/ 3 rect \/ 3 circ\u003c\/td\u003e\n\u003ctd\u003e5 points \/ 5 lines \/ 5 rect \/ 5 circ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhoto only\u003c\/td\u003e\n\u003ctd\u003ePhoto + MP4 \/ IRGD video\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e384×288 IR Detector with ≤40 mK NETD\u003c\/strong\u003e: Resolves subtle temperature gradients that signal early-stage component degradation; -20°C to 550°C (-4°F to 1022°F) measurement range covers electrical, mechanical, and process inspections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Focus Ring\u003c\/strong\u003e: Mechanical focus control delivers a sharp thermal image at any working distance — particularly important in cabinet inspections and standoff distances where autofocus systems hunt.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3.5″ IPS Touch Display (640×480)\u003c\/strong\u003e: Direct on-screen analyzer placement, palette selection, and isotherm tuning without menu navigation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-Screen Analyzer — 5 points \/ 5 lines \/ 5 rectangles \/ 5 circles\u003c\/strong\u003e: Build the analysis grid the job needs without exporting to a PC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi\/Lo Auto-Tracking + Icon Alarm\u003c\/strong\u003e: Auto-tracking marks the hottest and coldest points in the scene in real time; configurable Hi\/Lo alarms trigger an on-screen icon when thresholds are crossed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiometric Image Storage\u003c\/strong\u003e: Every saved JPEG embeds the underlying temperature data — emissivity, palette, isotherm, and analysis points can be re-applied after the fact, in-camera or in the included PC software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiometric Video Recording\u003c\/strong\u003e: MP4 for general documentation and IRGD radiometric video for post-shoot temperature analysis of dynamic events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWi-Fi + Bluetooth + Free Mobile App\u003c\/strong\u003e: Wi-Fi photo download, real-time video streaming to the mobile app, and Bluetooth voice annotation pairing — no subscription, no per-device license.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLaser Pointer + LED Work Light\u003c\/strong\u003e: Laser pointer for target identification on the visible camera reference; LED light extends the imager into low-light cabinets and crawlspaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-Swappable 5200 mAh Li-ion Battery (UT-M17)\u003c\/strong\u003e: Ships in a 2-pack; ≈5 hours (Wi-Fi off) per charge keeps a full inspection day on one set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP54 Sealed, 2 m Drop Rated\u003c\/strong\u003e: Industrial enclosure runs without a protective sleeve in dusty, damp, or impact-prone work areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUTi384G Detailed Features\u003c\/h2\u003e\n\u003ch3\u003e≤40 mK NETD with Manual Focus Ring\u003c\/h3\u003e\n\u003cp\u003eThe 384×288 detector reaches a noise-equivalent temperature difference of ≤40 mK, the level at which thermal patterns from a single overloaded conductor or a stuck bearing lift cleanly out of the background. The combination matters: high IFOV doesn't help if focus is fighting the operator, and a sharp image without sensitivity leaves the inspector guessing at borderline anomalies.\u003c\/p\u003e\n\u003cp\u003eThe manual focus ring sits on the lens barrel and turns with light pressure. Crews working through cabinet doors, at the top of a ladder, or with gloves get focus where they want it without an autofocus system hunting between the door frame and the busbar behind it. For repeating inspection routes, focus position can be set and left alone.\u003c\/p\u003e\n\u003ch3\u003e3.5″ IPS Touch Display\u003c\/h3\u003e\n\u003cp\u003eThe 640×480 IPS panel renders thermal scenes with the contrast and viewing-angle tolerance needed in industrial spaces — overhead lighting glare, side viewing from a ladder, or under direct sun outdoors. Touch input lets the inspector drop analyzer points and rectangles where the eye sees them, instead of nudging a cursor with the directional pad.\u003c\/p\u003e\n\u003cp\u003ePalette selection, isotherm mode, image-mode switching (Thermal \/ Visual \/ Fusion \/ PIP), and level-and-span adjustment are one-tap operations. The on-screen layout remains readable in landscape grip during long inspection walks.\u003c\/p\u003e\n\u003ch3\u003eLaser Pointer and LED Work Light\u003c\/h3\u003e\n\u003cp\u003eA center-aligned laser pointer marks the visible-camera centerline at the target — useful when calling out hot spots to a partner on the ground, or when documenting which breaker in a panel array is the one heating up. The integrated LED work light extends the imager into dark cabinets, basement utility rooms, and post-incident inspections where general lighting is offline.\u003c\/p\u003e\n\u003cp\u003eBoth controls live on the top-deck buttons within thumb reach of the trigger hand. The laser is independent of the trigger so it can be used for pointing without capturing an image.\u003c\/p\u003e\n\u003ch3\u003eWi-Fi, Bluetooth, and Free Mobile App\u003c\/h3\u003e\n\u003cp\u003eWi-Fi transfers radiometric JPEGs directly to a phone or tablet for tagging in the field — without USB cables or removing the microSD card. The same Wi-Fi link supports live video streaming to the mobile app, which a second person can monitor on a tablet while the lead inspector positions the camera. Bluetooth handles voice annotation pairing with the mobile app.\u003c\/p\u003e\n\u003cp\u003eThe mobile app and the PC analysis software are free, with no subscription, no per-seat license, and no expiring trial. Both deliver radiometric re-analysis — emissivity correction, palette change, isotherm tuning, multi-point analysis, and inspection-report export.\u003c\/p\u003e\n\u003ch3\u003eHi\/Lo Tracking with Icon Alarm\u003c\/h3\u003e\n\u003cp\u003eAuto-tracking continuously locates the hottest and coldest pixels in the live thermal scene and marks them on screen — so the inspector sees the worst case before deciding where to place fixed analyzer points. Threshold-based Hi\/Lo alarm modes trigger an animated on-screen icon when the tracked max or min crosses a configured value, useful on long inspection walks where the operator may not be looking at the screen every second.\u003c\/p\u003e\n\u003cp\u003eFive isotherm modes — Auto, Manual, Above, Below, and Section — highlight pixels in a chosen temperature band with a contrasting color, making it easy to spot borderline cases (a connection that's warm but not yet alarming) in a busy thermal image.\u003c\/p\u003e\n\u003ch3\u003e5 MP Visible Camera with Thermal Fusion\u003c\/h3\u003e\n\u003cp\u003eThe 5 MP visible-light camera captures a high-resolution visual reference alongside every thermal frame, so equipment, nameplates, and surrounding context appear in the inspection record. Picture-in-picture overlays the thermal image inside the visual frame; fusion mode blends thermal data onto edges detected in the visual image to make specific components — connectors, breakers, motor housings — easier to identify in reports later.\u003c\/p\u003e\n\u003ch3\u003eRadiometric JPEG — Post-Shoot Emissivity Correction\u003c\/h3\u003e\n\u003cp\u003eThe thermal imager saves every photo as a radiometric JPEG: the visible image is rendered for review, but the underlying calibrated temperature data is embedded in the same file. The result is that emissivity assumptions don't have to be locked in at capture time. Inspectors who later learn a measured surface was bare metal rather than painted (or vice versa) can re-apply the correct emissivity to images already on file and recover accurate temperatures.\u003c\/p\u003e\n\u003cp\u003eThe in-camera image editor (Settings → Picture) supports emissivity adjustment, palette change, analyzer-object editing, and isotherm reconfiguration directly on saved photos. The same operations are available in the PC and mobile software, with export to inspection-report templates.\u003c\/p\u003e\n\u003ch3\u003eRadiometric Video Recording\u003c\/h3\u003e\n\u003cp\u003eThe UTi384G records thermal video in two selectable formats: standard MP4 for general documentation and IRGD for radiometric video where the temperature data is preserved frame-by-frame. IRGD clips can be re-analyzed in the PC software — analyzer points, isotherm bands, and temperature parameters can be applied after recording to study transient thermal events (motor startup, heating cycles, switching transients) at the workstation rather than guessing at parameters in the field.\u003c\/p\u003e\n\u003ch3\u003eDetachable Li-Ion Battery Pack\u003c\/h3\u003e\n\u003cp\u003eThe 5200 mAh Li-ion battery pack (UT-M17) is field-swappable in seconds and ships in a 2-pack so a spare can stay on the charger during inspection rotations. ≈5 hours (Wi-Fi off) of continuous operation per charge covers a full inspection day; the spare extends runtime without an AC connection. The replacement battery (UT-M17) is a separate orderable SKU for keeping additional spares on-truck or in the shop.\u003c\/p\u003e\n\u003ch3\u003eIP54 Rated, 2 m Drop Protected\u003c\/h3\u003e\n\u003cp\u003eThe IP54 enclosure protects against dust ingress and water spray from any direction — the operating environment for plant-floor electrical inspection, outdoor PV string walkdowns, and HVAC mechanical-room work. The 2 m (6.6 ft) drop rating means a slip from a ladder rung or a benchtop doesn't end the inspection day. The imager runs without a separate protective sleeve, so controls and the focus ring stay accessible.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eElectrical Inspection — Switchgear, Panels, and Connection Points\u003c\/h3\u003e\n\u003cp\u003eElectrical maintenance teams use the imager to walk distribution panels, MCC lineups, and switchgear lineups, identifying loose or corroded connections by their thermal signature before they fail. The radiometric image storage means a borderline connection that read 38°C against a 25°C ambient at first inspection can be re-analyzed months later against fresh ambient data to confirm whether the situation is degrading. Hi\/Lo tracking surfaces the worst point in a busy panel without manual analyzer setup, speeding routine walkdowns.\u003c\/p\u003e\n\u003ch3\u003eMechanical and Rotating Equipment Condition Monitoring\u003c\/h3\u003e\n\u003cp\u003eMotor housings, bearing pillow blocks, gearbox cases, pump seals, and conveyor drive rollers all telegraph developing failures through temperature change before audible or vibratory symptoms appear. The 40 mK sensitivity surfaces the 3-5°C rise that distinguishes an alignment issue from normal operating temperature, and the manual focus ring lets crews work at the safe standoff distance from running equipment.\u003c\/p\u003e\n\u003ch3\u003eBuilding Diagnostics — Insulation, Moisture, and HVAC\u003c\/h3\u003e\n\u003cp\u003eBuilding inspectors and HVAC technicians use the imager to map insulation gaps in walls and ceilings, locate moisture intrusion behind finishes, and verify proper hot- and cold-air distribution from supply diffusers. The 3.5″ touch display makes it practical to drop analyzer rectangles on suspect areas in the field. Radiometric storage allows return visits to compare against baseline images.\u003c\/p\u003e\n\u003ch3\u003eSolar PV Operations and Maintenance\u003c\/h3\u003e\n\u003cp\u003eSolar O\u0026amp;M crews scan string inverters, combiner boxes, and module strings for cell- level hot spots indicating bypass diode failures, shading damage, or solder-joint degradation. The Wi-Fi link supports tagging anomalies to a phone-based site map in real time. The IP54 rating and 2 m drop tolerance suit rooftop and ground-mount environments where the imager is regularly handed up to mounted work or set down on rough surfaces.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and What's in the Box\u003c\/h2\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUTi384G thermal imager\u003c\/li\u003e\n\u003cli\u003e5200 mAh Li-ion battery pack — UT-M17 (×2)\u003c\/li\u003e\n\u003cli\u003eType-C USB cable\u003c\/li\u003e\n\u003cli\u003emicroSD card\u003c\/li\u003e\n\u003cli\u003eHand strap\u003c\/li\u003e\n\u003cli\u003eUser documentation and download guide card\u003c\/li\u003e\n\u003cli\u003eToolbox and gift box\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAvailable Separately\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUT-M17 — Replacement 5200 mAh Li-ion battery pack (when an additional spare beyond the 2 included is needed)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the saved image radiometric, or just a thermal picture?\u003c\/p\u003e\n\u003cp\u003eRadiometric. Every photo the UTi384G saves is a JPEG that embeds the underlying temperature data — emissivity, palette, isotherm, and analyzer points can be edited after the fact, either in the camera (Settings → Picture editor) or in the included PC and mobile software. This means an inspection done with the wrong emissivity setting can be recovered without revisiting the site.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow does the UTi256G \/ UTi384G compare to UNI-T's other thermal imagers?\u003c\/p\u003e\n\u003cp\u003eThe G Pro Imager sits in UNI-T's industrial mid-tier: 40 mK sensitivity, manual focus ring, touch display, Wi-Fi\/Bluetooth, and radiometric image storage. Step up to the UTi384J or UTi640J for continuous autofocus and an interchangeable lens system. Step up further to the UTi740X, UTi740XH, UTi760X, or UTi760XH for laser-assisted autofocus, AI voice commands, and a six-lens system including the high-temperature lens for measurements to 2200°C.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's the difference between MP4 and IRGD video on the UTi384G?\u003c\/p\u003e\n\u003cp\u003eMP4 saves a standard video file useful for documentation and sharing — the visible thermal image is preserved but the underlying temperature data is not. IRGD (infrared radiometric video) preserves the per-pixel temperature data at every frame, so the recording can be re-analyzed in the PC software with new emissivity settings, new palettes, or new analyzer placements. Use MP4 for shareable clips; use IRGD when the recording will be the source for measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow long does one battery charge last in the UTi384G?\u003c\/p\u003e\n\u003cp\u003eApproximately five hours of continuous operation with Wi-Fi off — a full inspection day in most workflows. The imager ships with two batteries so a spare can stay on the charger; a third (UT-M17) can be ordered separately.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIR Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e384×288\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNETD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 40mK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C (-4 °F) to 550 °C (1022 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±2 °C or ±2% (whichever greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42° × 30°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectral Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 - 14µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePixel Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefresh Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpatial Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.91mrad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFocus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual Focus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Zoom\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x, 4x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImage Blending\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsotherm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImage Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal, Visual image, Fusion, PIP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImage Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRadiometric JPEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMP4 \u0026amp; IRGD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLaser Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Laser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLaser Pointer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlashlight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn Screen Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Points\/5 Lines\/5 Rectangles\/5 Circles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Camera\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5MP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiFi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBluetooth App\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Type-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in 8GB \u0026amp; 32GB SD card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIPS LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e640×480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLanguages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnglish, French, German, Italian, Spanish, Swedish, Polish, Czech, Russian, Portuguese, Arabic, Japanese, Korean\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5200 mAh detachable Li-ion battery pack (UT-M17)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 5h (with Wi-Fi off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e880 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e261 × 104 × 97 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Thermal%20Camera%20Datasheets\/UTi256G%26UTi384G%20Data%20Sheet.pdf\"\u003eUTi384G Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Thermal%20Camera%20User%20Manuals\/UTi256G_UTi384G_User_Manual.pdf\"\u003eUTi384G User Manual\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/thermal.uni-trend.com\/product\/uti384g\/#Downloadsf52d-5897\"\u003eUTi384G Software\/Firmware\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275018793258,"sku":"180700100085X","price":2999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/7103\/3642\/files\/UTi384G_2_sq.jpg?v=1787007140"},{"product_id":"ut-p42-150-khz-200a-ac-dc-current-probe","title":"UT-P42 150 kHz 200A AC\/DC Current Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e150kHz bandwidth, 200A AC\/DC current probe for oscilloscopes. Measures current waveforms non-invasively in power electronics, motor drives, and switch-mode circuits. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Invasive Measurement\u003c\/strong\u003e — Clamp-on design requires no circuit interruption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBNC Connection\u003c\/strong\u003e — Standard BNC connector for direct connection to UNI-T oscilloscopes and other oscilloscopes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-P42_User_Manual.pdf\"\u003eUT-P42 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275018760490,"sku":"190500100133X","price":459.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/7103\/3642\/files\/UT-P42_1_sq.jpg?v=1787007139"},{"product_id":"utx325mr-long-distance-thermal-monocular-with-laser-range","title":"UTx325MR Long-Distance Thermal Monocular with Laser Range","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003ch3 data-pm-slice=\"1 3 []\"\u003e\u003cspan\u003e\u003cstrong\u003eUNI-T UTx325MR\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan\u003eLong-Range Precision with Laser Accuracy\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe UNI-T UTx325MR is built for professionals who demand unparalleled accuracy and performance for long-range thermal detection and distance measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith a 25mm lens, the UNI-T UTx325MR is optimized for long-range detection, ensuring sharp imaging and reliable performance in challenging environments. It features \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003elaser range finding\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e, which offers precision distance measurements that far surpass the speed and accuracy of stadiametric methods.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLaser range finding allows professionals to measure distances with exactitude, providing the critical information needed for time-sensitive operations such as search and rescue, wildlife monitoring, or perimeter security. Combined with its rugged durability and advanced thermal sensitivity, the UNI-T UTx325MR is the ultimate tool for demanding users.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIR Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: 400×300 pixels for detailed thermal imaging\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLens Focal Length\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: 25mm for long-range performance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eThermal Sensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: ≤25mK for superior detection accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eField of View (FOV)\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: 10.5° × 7.9° for precise scanning\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRange Finding\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: Laser\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: 6+ hours of continuous use\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurability\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: IP67 waterproof and drop-resistant up to 2 meters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAdditional Features\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: Hot Trace, Wi-Fi Live Streaming\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the detection range of the UTx325MR?\u003c\/p\u003e\n\u003cp\u003eDetection range depends on the target size and thermal contrast. The UTx325MR's specifications list the maximum detection range for a standard 1.7m × 0.5m target. Actual usable range for identification is typically 30-50% of the maximum detection distance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the UTx325MR waterproof?\u003c\/p\u003e\n\u003cp\u003eThe UTx325MR carries an IP rating for dust and water resistance. Check the specifications tab for the exact IP rating. The device is designed for outdoor use in varying weather conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's included with the UTx325MR?\u003c\/p\u003e\n\u003cp\u003eThe UTx325MR ships with the monocular, carrying case, USB charging cable, lens cloth, and user manual. Check the specifications tab for the complete package contents.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIR Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400×300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNETD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 25mK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5° × 7.9°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectral Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 - 14µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePixel Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefresh Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFocus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual Focus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1318m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Zoom\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x, 4x, 8x \/ 1.0 - 8x continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImage Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImage Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePNG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMP4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLaser LRF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiFi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMobile App\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Xplorer (Android \u0026amp; iOS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Type-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in 16GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.39in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1024×768\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLanguages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnglish, French, German, Spanish, Italian, Russian\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3250 mAh detachable Li-ion battery (UT-M21)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 4h (with Wi-Fi off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e357 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 × 71.5 × 38.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Thermal%20Camera%20Datasheets\/UTx313MR%26318MR%26325MR%26335MR%20Data%20Sheet.pdf\"\u003eUTx325MR Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Thermal%20Camera%20User%20Manuals\/UTx313MR_UTx318MR_UTx325MR_User_Manual.pdf\"\u003eUTx325MR User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275018727722,"sku":"180700300068X","price":2299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/7103\/3642\/files\/UTx325MR-4.png?v=1787007139"},{"product_id":"utl1020s-e-200w-programmable-dc-electronic-load","title":"UTL1020S-E 200W Programmable DC Electronic Load","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTL1020S-E\u003c\/strong\u003e is a single-channel programmable DC electronic load rated 200 W, 0–150 V, 0–30 A. It runs four constant modes — CC, CV, CR, CP — plus eleven additional test modes including dynamic, OVP, OCP, time, CR-LED, battery, automatic list, short-circuit, load-effect, combination, and list, for 15 test modes in total. Synchronous sampling reaches 500 kHz with high-performance DSP processing and a self-adaptive voltage and current waveform display on the 4.3-inch TFT LCD.\u003c\/p\u003e\n\u003cp\u003eDynamic mode pulls load at up to 50 kHz so current and voltage peaks — Vpp and Ipp — can be observed directly. The load also provides on-screen ripple measurement, a rear-panel Sense terminal for remote voltage compensation, and SCPI remote control over RS232 with a HANDLER interface and USB Host port for data logging and automated production test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eChoosing Your Model — 200 W 15-Mode Load\u003c\/h2\u003e\n\u003cp\u003eTwo 200 W models share the same load architecture, the same 15 test modes, the same accuracy class, and the same 0–150 V \/ 0–30 A input envelope. They differ in one axis only: measurement resolution.\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUTL1020S\u003c\/strong\u003e (high-resolution)\u003c\/td\u003e\n\u003ctd\u003eCurrent resolution 0.01 mA \/ 0.1 mA, voltage readback 0.01 mV \/ 0.1 mV — finer metering for precision readback work.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUTL1020S-E\u003c\/strong\u003e (standard resolution)\u003c\/td\u003e\n\u003ctd\u003eSame 200 W load, same 15 modes; current resolution 0.1 mA \/ 1 mA, voltage readback 0.1 mV \/ 1 mV. The lower-cost choice when fine readback resolution is not the deciding factor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eThis page describes the \u003cstrong\u003eUTL1020S-E\u003c\/strong\u003e. Capability, test modes, protection, and interfaces below apply to both 200 W models; the Specifications table lists this model's resolution figures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 W, 0–150 V, 0–30 A single-channel load\u003c\/strong\u003e — CC, CV, CR, CP basic modes with dual high\/low input ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15 test modes\u003c\/strong\u003e — CC, CV, CR, CP, dynamic, OVP, time, OCP, CR-LED, battery, automatic list, short circuit, load effect, combination, list.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 kHz synchronous sampling\u003c\/strong\u003e — high sampling density for accurate transient capture and reduced measurement omission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e50 kHz dynamic mode\u003c\/strong\u003e — programmable rise\/fall slope (0.0006–3 A\/µs) simulates real changing load conditions; Vpp \/ Ipp observed directly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery test with charge and discharge curves\u003c\/strong\u003e — records both charge and discharge curves for battery characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic list test\u003c\/strong\u003e — up to 200-step programmable multi-mode sequences for automated, repeatable testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-screen ripple measurement and real-time waveform\u003c\/strong\u003e — ripple readout in the screen corner; [WAVE] key shows live V\/I waveform without an external oscilloscope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote compensation (Sense terminal)\u003c\/strong\u003e — rear-panel Sense terminal eliminates lead voltage-drop error at high current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS232 \/ USB Host \/ HANDLER, SCPI protocol\u003c\/strong\u003e — PC software control, USB-drive screenshots and list import\/export, HANDLER for ATE integration.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCurrent resolution 0.1 mA \/ 1 mA, voltage readback 0.1 mV \/ 1 mV, 16-bit CR, 3 years standard + 2 year extension.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTL1020S-E Details\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e15 Test Modes for Power, Battery, and LED-Driver Validation\u003c\/h3\u003e\n\u003cp\u003eFour constant modes — CC (constant current), CV (constant voltage), CR (constant resistance), CP (constant power) — plus eleven more: dynamic, OVP, time, OCP, CR-LED, battery, automatic list, short-circuit, load effect, combination, and list. The CR-LED mode simulates real LED forward-voltage behavior for LED-driver testing; battery mode records charge and discharge curves; combination mode pairs two basic modes (CR+CC, CV+CR, CV+CC) for more realistic DUT conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_test-modes_sq.jpg?v=1770678169\" alt=\"UTL1020S-E 15 test modes covering power, battery, and LED-driver validation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e15 Test Modes for Power, Battery, and LED-Driver Validation\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_dynamic-testing_sq.jpg?v=1770678169\" alt=\"UTL1020S-E dynamic mode 50 kHz transient load simulation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eDynamic Mode — 50 kHz Transient Load Simulation\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eDynamic Mode — 50 kHz Transient Load Simulation\u003c\/h3\u003e\n\u003cp\u003eDynamic mode pulls load at frequencies up to 50 kHz with T1\/T2 timing from 10 µs to 50 s (1 µs resolution) and a programmable rising\/falling current slope of 0.0006 A\/µs to 3 A\/µs. The current and voltage peak waveforms are observed directly on screen with Vpp and Ipp measurement, so transient response and overshoot of the device under test can be characterized without a separate oscilloscope.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eBattery Test with Charge and Discharge Curves\u003c\/h3\u003e\n\u003cp\u003eBattery mode performs constant-current or constant-power discharge testing and records the full discharge curve. The UTL1020S-E captures both the discharge and the charging curve, so capacity, internal-resistance behavior, and cycle characteristics are traceable from a single instrument — useful for battery-pack, BMS, and power-bank validation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_battery-testing.gif\" alt=\"UTL1020S-E battery test recording charge and discharge curves\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBattery Test with Charge and Discharge Curves\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_auto-list.gif\" alt=\"UTL1020S-E automatic list test with up to 200 programmable steps\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eAutomatic List Test — 200-Step Programmable Sequences\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eAutomatic List Test — 200-Step Programmable Sequences\u003c\/h3\u003e\n\u003cp\u003eThe automatic list test runs editable multi-step, multi-mode sequences with up to 200 steps. Set the appropriate load value and mode for each step and the list executes the full test process automatically. List files save to internal memory or a USB drive and can be imported, so a validated production-test sequence transfers between units quickly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eOn-Screen Ripple Measurement and Real-Time Waveform\u003c\/h3\u003e\n\u003cp\u003eRipple is measured and displayed directly in the corner of the screen, replacing a separate oscilloscope measurement for routine power-supply ripple checks. Pressing the [WAVE] function key shows the live voltage and current waveform, with the self-adaptive display scaling automatically to the signal.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_ripple-measurement_sq.jpg?v=1770678169\" alt=\"UTL1020S-E on-screen ripple measurement and real-time waveform display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eOn-Screen Ripple Measurement and Real-Time Waveform\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_ovp_sq.jpg?v=1770678169\" alt=\"UTL1020S-E OVP and OCP protection-function testing\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eOVP and OCP Protection Testing\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eOVP and OCP Protection Testing\u003c\/h3\u003e\n\u003cp\u003eSet the protection threshold according to the device under test and the UTL1020S-E measures the protection function and the protection response time. Overvoltage protection triggers with delayed protection at ≥ 152 V and immediate protection at ≥ 165 V; overcurrent protection at ≥ 30.3 A delayed and ≥ 33 A immediate; overpower at ≥ 202 W delayed and ≥ 220 W immediate. Instrument protection can also be turned off to prevent false alarms during characterization.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eLoad Effect Test\u003c\/h3\u003e\n\u003cp\u003eThe load effect test automatically measures and calculates load-regulation results from the configured test values, so power-supply load regulation is characterized without manual point-by-point measurement and calculation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_load-effect-test_sq.jpg?v=1770678169\" alt=\"UTL1020S-E automated load effect \/ load regulation test\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eLoad Effect Test\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_time-test_sq.jpg?v=1770678169\" alt=\"UTL1020S-E time test measuring power-supply rise and fall time\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eTime Test — Rise and Fall Time of the Power Supply\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eTime Test — Rise and Fall Time of the Power Supply\u003c\/h3\u003e\n\u003cp\u003eTime test measures the rise and fall times of the device under test against configured thresholds, with 1 µs timing resolution and ±100 ppm timing accuracy, for power-supply turn-on \/ turn-off and transient-timing characterization.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe 200 W 15-mode envelope — CC\/CV\/CR\/CP plus dynamic, battery, list, protection, load-effect, and combination modes with 500 kHz sampling — covers R\u0026amp;D and production test for power electronics.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching power-supply and adapter test\u003c\/strong\u003e — load regulation, ripple, transient response, and protection-function verification from one instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery and battery-pack characterization\u003c\/strong\u003e — charge and discharge curve recording for capacity, BMS, and cycle testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED-driver validation\u003c\/strong\u003e — CR-LED mode simulates real LED forward-voltage behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger and power-bank testing\u003c\/strong\u003e — automatic list sequences for repeatable multi-step production test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC-DC converter and module test\u003c\/strong\u003e — dynamic loading at up to 50 kHz to characterize transient overshoot and recovery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated production test (ATE)\u003c\/strong\u003e — SCPI over RS232 plus HANDLER interface for test-line integration; list import\/export for fast line setup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003ch3\u003eIncluded with Every Unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC power cord\u003c\/li\u003e\n\u003cli\u003eRS232 communication cable\u003c\/li\u003e\n\u003cli\u003ePlug-in terminal block (5.08-2P) and screw-free spring terminal block (2.54-6P)\u003c\/li\u003e\n\u003cli\u003eSpare fuse (2 pcs)\u003c\/li\u003e\n\u003cli\u003eCertificate of calibration and multi-language safety precautions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional Test Leads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0615-OO\u003c\/strong\u003e — double O-type terminal, 60 A \/ 1.5 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0320-UU\u003c\/strong\u003e — double U-type terminal, 30 A \/ 2 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0312-UU\u003c\/strong\u003e — double U-type terminal, 30 A \/ 1.2 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0110-BB\u003c\/strong\u003e — double fold-insert, 10 A \/ 1 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0110-BU\u003c\/strong\u003e — fold-insert to U-type, 10 A \/ 1 m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUTL1000S Series\u003c\/h3\u003e\n\u003cp\u003eFour models share the same chassis, 15 test modes, 500 kHz sampling, accuracy class, and 0–150 V \/ 0–30 A input envelope:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTL1020S\u003c\/strong\u003e — 200 W, high-resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTL1020S-E\u003c\/strong\u003e — 200 W, standard resolution (this product)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTL1040S\u003c\/strong\u003e — 400 W, high-resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTL1040S-E\u003c\/strong\u003e — 400 W, standard resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the difference between the UTL1020S-E and the UTL1020S?\u003c\/p\u003e\n\u003cp\u003eBoth are 200 W loads with the same 15 test modes, the same accuracy class, and the same 0–150 V \/ 0–30 A input envelope. The difference is measurement resolution: the UTL1020S-E resolves current to 0.1 mA \/ 1 mA and voltage readback to 0.1 mV \/ 1 mV across its low and high ranges. The high-resolution model is suited to precision readback work; the standard-resolution model is the lower-cost choice when fine readback resolution is not the deciding factor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow many test modes does the UTL1020S-E have, and what are they?\u003c\/p\u003e\n\u003cp\u003e15 modes: CC, CV, CR, CP, dynamic, OVP, time, OCP, CR-LED, battery, automatic list, short circuit, load effect, combination, list. The four constant modes (CC, CV, CR, CP) cover standard load testing; the remaining modes add transient, protection, battery, LED-driver, automated, and combination testing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan the UTL1020S-E test batteries?\u003c\/p\u003e\n\u003cp\u003eYes. Battery mode performs discharge testing and records both the discharge and the charging curve, so capacity and cycle behavior are traceable from the instrument — useful for battery-pack, BMS, and power-bank validation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes it measure ripple without an oscilloscope?\u003c\/p\u003e\n\u003cp\u003eYes. Ripple is measured and displayed in the corner of the screen, and the [WAVE] key shows the live voltage and current waveform, so routine ripple and waveform checks do not require a separate oscilloscope.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the Sense terminal for?\u003c\/p\u003e\n\u003cp\u003eAt high current, lead resistance creates a voltage drop between the load and the device under test. The rear-panel Sense terminal measures voltage at the DUT output terminal directly (remote compensation), so the displayed voltage reflects the DUT rather than the voltage after the test leads.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow is the UTL1020S-E controlled remotely?\u003c\/p\u003e\n\u003cp\u003eOver RS232 using the standard SCPI protocol with the included PC data-acquisition software. A HANDLER interface supports automated test-line integration, and a USB Host port accepts a USB drive for screenshots and for importing or exporting list files.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_test-modes_sq.jpg?v=1770678169\" alt=\"UTL1020S-E 15 test modes covering power, battery, and LED-driver validation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e15 Test Modes for Power, Battery, and LED-Driver Validation\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_dynamic-testing_sq.jpg?v=1770678169\" alt=\"UTL1020S-E dynamic mode 50 kHz transient load simulation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eDynamic Mode — 50 kHz Transient Load Simulation\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_battery-testing.gif\" alt=\"UTL1020S-E battery test recording charge and discharge curves\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBattery Test with Charge and Discharge Curves\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_auto-list.gif\" alt=\"UTL1020S-E automatic list test with up to 200 programmable steps\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eAutomatic List Test — 200-Step Programmable Sequences\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_ripple-measurement_sq.jpg?v=1770678169\" alt=\"UTL1020S-E on-screen ripple measurement and real-time waveform display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eOn-Screen Ripple Measurement and Real-Time Waveform\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_ovp_sq.jpg?v=1770678169\" alt=\"UTL1020S-E OVP and OCP protection-function testing\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eOVP and OCP Protection Testing\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_load-effect-test_sq.jpg?v=1770678169\" alt=\"UTL1020S-E automated load effect \/ load regulation test\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eLoad Effect Test\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_time-test_sq.jpg?v=1770678169\" alt=\"UTL1020S-E time test measuring power-supply rise and fall time\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eTime Test — Rise and Fall Time of the Power Supply\u003c\/span\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput power (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–15 V (low) \/ 0–150 V (high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–3 A (low) \/ 0–30 A (high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum operating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 V ± 0.1 V at 30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCV mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange 0.1–150 V, resolution 1 mV, accuracy ±(0.03% + 0.05% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCC mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResolution 0.1 mA \/ 1 mA (low \/ high), accuracy ±(0.03% + 0.05% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCR mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange 0.05 Ω – 10 kΩ, resolution 16 bits, accuracy (0.1 + 0.01R)%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCP mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange 200 W, resolution 10 mW, accuracy ±(0.1% + 0.1% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadback voltage resolution (CC\/CP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV \/ 1 mV (low \/ high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadback voltage resolution (CV\/CR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadback current resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mA \/ 1 mA (low \/ high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadback accuracy (V \/ I \/ P)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(0.02% + 0.3% FS) \/ ±(0.03% + 0.05% FS) \/ ±(0.1% + 0.1% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic mode T1 \u0026amp; T2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 µs – 50 s, 1 µs resolution; timing accuracy 1 µs \/ 1 ms ±100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic rise\/fall slope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0006 A\/µs – 3 A\/µs (min. rise time 10 µs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSynchronous sampling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 kHz synchronous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverpower protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDelay ≥ 202 W, immediate ≥ 220 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercurrent protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDelay ≥ 30.3 A, immediate ≥ 33 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDelay ≥ 152 V, immediate ≥ 165 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver-temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit (CC \/ CV \/ CR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 30 A \/ 0 V \/ 60 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15: CC, CV, CR, CP, dynamic, OVP, time, OCP, CR-LED, battery, automatic list, short circuit, load effect, combination, list\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple display \/ waveform record\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes \/ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput terminal impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A (110 V) \/ 0.25 A (220 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232, USB Host, HANDLER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3-inch TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 V \/ 220 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e215 × 88 × 372 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.73 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C – 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy temperature \/ calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 ± 5 °C \/ 1 \/ year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_Series_DC_Electronic_Load_-_Data_Sheet.pdf?v=1772202746\"\u003eUTL1020S-E Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_Series_DC_Electronic_Load_-_Manuals.zip?v=1772202727\"\u003eUTL1020S-E User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019055402,"sku":"181500100142X","price":439.0,"currency_code":"USD","in_stock":true}]},{"product_id":"utp3305-3ch-335w-32v-5a-linear-dc-power-supply","title":"UTP3305 3Ch 335W 32V\/5A Linear DC Power Supply","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UTP3305 is a 335W three-channel linear bench supply for benches that need higher current than a 3A supply provides without giving up clean linear output. Two adjustable channels deliver 0–32V at 0–5A; a third channel provides a fixed 5V at 3A for logic-level power. Knobs, banana jacks, OVP\/OCP via current-limit protection, and a front panel a first-year student gets back to default settings in under 30 seconds.\u003c\/p\u003e\n\u003cp\u003eLinear regulation keeps output ripple under 1mVrms — no switching artifacts, no EMI signature competing with the circuit you're actually trying to characterize. CH1 and CH2 combine in series (up to 64V) or parallel (up to 10A), and a master-slave tracking mode keeps CH1 and CH2 synchronized when matched rails are needed for dual-supply analog work.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Channels, 335W Total\u003c\/strong\u003e — CH1 and CH2: 0–32V \/ 0–5A adjustable. CH3: fixed 5V \/ 3A for logic-level power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Topology, ≤1 mVrms Ripple\u003c\/strong\u003e — Clean DC output with no switching frequency, no harmonic spurs, and load regulation of CV ≤1×10⁻⁴ + 3 mV.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto CV\/CC Crossover with Current Limit Protection\u003c\/strong\u003e — The supply transitions automatically between constant-voltage and constant-current operation when the load steps, protecting both the DUT and the supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries and Parallel Modes\u003c\/strong\u003e — Combine CH1+CH2 for up to 64V series or 10A parallel — front-panel selectable, no external wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCH1\/CH2 Master-Slave Tracking\u003c\/strong\u003e — Tracking mode synchronizes CH1 and CH2 for matched-rail testing (op-amp ±supplies, balanced analog stages, dual-supply mixed-signal designs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Bit Voltage and Current Dual Display\u003c\/strong\u003e — Independent voltage and current readouts per channel. No menus, no hidden settings — what you see is what the channel is doing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput ON\/OFF Control\u003c\/strong\u003e — Front-panel master output button keeps you in command of when current actually leaves the supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKnob-and-Button Operation\u003c\/strong\u003e — No firmware to update, no PC software to install, no LAN port to configure. Front-panel only — designed to behave the same way on day one and year five.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eBench Power That Stays Out of the Way\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UTP3305 is the supply you put on a bench when the day's work is upstream of the power supply — circuit prototyping, board-level service, instructional labs where the lesson is signals or amplifiers, not procurement of a programmable instrument. The 5A current capability handles the higher-power loads where the UTP3303 runs out of headroom: small motors, transmitter front-ends, higher-current LED drive circuits, and parallel-mode 10A loads where two channels combine for current-hungry work.\u003c\/p\u003e\n\u003cp\u003eFor teaching labs and trade-school programs running 10–30 stations, this is the operational pitch: every student gets the same instrument with the same workflow, every shift. For service shops and small-team R\u0026amp;D benches, it's the supply you reach for when you don't want to think about the supply.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cdiv class=\"product-app-grid\"\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eTeaching Labs \u0026amp; Trade Schools\u003c\/h3\u003e\n\u003cp\u003ePer-station cost that lets a 20-bench classroom stay inside budget, with 5A current handling the higher-power lab exercises (motor drive, power amplifiers, LED arrays).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eAnalog Bench Development\u003c\/h3\u003e\n\u003cp\u003eDual 0–32V \/ 5A adjustable channels with master-slave tracking power op-amp ±supplies, audio amplifiers, and balanced analog stages with current headroom for class-AB and high-bias designs. Ripple under 1 mVrms keeps supply noise out of the measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eService \u0026amp; Repair\u003c\/h3\u003e\n\u003cp\u003eReliable bench supply for board-level service work where the device under test is a higher-current load — small motor drives, switch-mode supplies under test, automotive electronics. CV\/CC auto crossover handles unknown loads safely.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eMaker \u0026amp; Hobbyist Workshops\u003c\/h3\u003e\n\u003cp\u003eThree channels of clean linear power at a price point that makes sense for a workshop, with the current to drive higher-power projects: amateur radio rigs, EV-conversion bench testing, robotics prototyping. No software stack to maintain.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes the UTP3305 have USB or SCPI?\u003c\/p\u003e\n\u003cp\u003eNo. The UTP3305 is a fully analog, knob-and-button bench supply — no USB data interface, no LAN, no SCPI command set, no PC software. If your workflow needs SCPI control, the programmable counterparts in the UNI-T linear PSU family are the UDP3303C and UDP3305C (USB + RS-232) and the UDP3000S series (USB + LAN + LXI with web interface).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's the difference between the UTP3305 and the UTP3303?\u003c\/p\u003e\n\u003cp\u003eOutput current. UTP3305 delivers 0–5A on CH1 and CH2 (335W total). UTP3303 delivers 0–3A on CH1 and CH2 (207W total). Voltage range, ripple, regulation, display, and feature set are otherwise identical between the two. Choose UTP3303 if 3A is enough; choose UTP3305 when you need to source above 3A on a single rail or up to 10A in parallel mode.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhy a linear supply instead of switching?\u003c\/p\u003e\n\u003cp\u003eLinear topology produces fundamentally cleaner output — no switching frequency, no harmonic spurs, ripple under 1 mVrms. For analog bench work, audio circuits, low-noise sensor development, and any precision measurement where supply noise shows up in the result, the difference is measurable. The trade-off is lower efficiency and more heat, which at this power level on a bench is not a meaningful constraint.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's included with the UTP3305?\u003c\/p\u003e\n\u003cp\u003eThe UTP3305 ships with the instrument, power cord, output cables, English user manual Ships from authorized US dealer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUTP3305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 (CH1, CH2 adjustable; CH3 fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH1, CH2: 0–32V\u003cbr\u003eCH3: 5V (fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH1, CH2: 0–5A\u003cbr\u003eCH3: 3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e335W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCV ≤1×10⁻⁴ + 3 mV\u003cbr\u003eCC ≤2×10⁻⁴ + 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple \u0026amp; Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage: ≤1 mVrms\u003cbr\u003eCurrent: ≤3 mArms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Regulation Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCV: 100 mV (typical)\u003cbr\u003eCC: 10 mA (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTracking Bias (CH1\/CH2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5×10⁻³ + 10 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-bit voltage and current dual display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndependent, Series, Parallel, CH1\/CH2 Master-Slave Tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent limit protection with auto CV\/CC crossover, output ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReliability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMTBF ≥ 2,000 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V \/ 230V AC, 47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e260 × 170 × 315 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=43\"\u003eUTP3305 Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019088170,"sku":"181730090193X","price":225.0,"currency_code":"USD","in_stock":true}]},{"product_id":"mso5000hd-bw5mt1g-1ghz-bandwidth-upgrade","title":"MSO5000HD-BW5MT1G 1GHz bandwidth upgrade","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO5000HD-BW5MT1G upgrades your MSO5054HD from 500MHz to 1GHz bandwidth — capturing faster edges and higher-frequency content without replacing the instrument. The upgrade is a software license key; the hardware already supports 1GHz.\u003c\/p\u003e\n\u003cp\u003eA 500MHz oscilloscope faithfully reproduces signals up to roughly 500MHz. Clock signals, digital buses, or switching transients with content above that are attenuated — rounded edges, reduced amplitude. Upgrading to 1GHz gives you the headroom to see what's actually happening.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e500MHz → 1GHz Bandwidth\u003c\/strong\u003e — Upgrades all analog channels on your MSO5054HD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFaster Rise Times\u003c\/strong\u003e — Higher bandwidth means accurately capturing faster edges — critical for signal integrity on high-speed interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Hardware Changes\u003c\/strong\u003e — Bandwidth is software-defined. Enter the key and operate at 1GHz immediately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInvestment Protection\u003c\/strong\u003e — Start at a lower bandwidth and unlock higher bandwidth later with a software license, as requirements grow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrowing Requirements\u003c\/strong\u003e — A new project needs more than 500MHz bandwidth. Upgrade instead of buying a new oscilloscope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Integrity\u003c\/strong\u003e — Compliance testing requires capturing fast edges accurately. The 1GHz upgrade gives you bandwidth to see the true signal shape.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis upgrade applies \u003cstrong\u003eonly\u003c\/strong\u003e to the MSO5054HD (500MHz). Not needed if your instrument already has 1GHz bandwidth or higher.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhich model does this apply to?\u003c\/h3\u003e\n\u003cp\u003eExclusively the MSO5054HD (500MHz). If your instrument already has 1GHz bandwidth or higher, this upgrade is not needed.\u003c\/p\u003e\n\u003ch3\u003eDoes bandwidth affect sample rate or memory?\u003c\/h3\u003e\n\u003cp\u003eNo. Sample rate and memory depth are unchanged. Only analog bandwidth is unlocked.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019120938,"sku":"191502500016","price":1999.0,"currency_code":"USD","in_stock":true}]},{"product_id":"mso5000hd-timing-advanced-timing-analysis","title":"MSO5000HD-TIMING Advanced Timing Analysis","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO5000HD-TIMING adds advanced timing analysis for digital signal characterization — setup time, hold time, propagation delay, and timing statistics.\u003c\/p\u003e\n\u003cp\u003eAutomates timing measurements that would otherwise require manual cursor placement across multiple channels. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Channel Timing\u003c\/strong\u003e — Measure timing relationships across multiple channels simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSetup and Hold\u003c\/strong\u003e — Automated setup\/hold measurement for data\/clock pairs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePropagation Delay\u003c\/strong\u003e — Signal delay between input\/output with statistical analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTiming Histograms\u003c\/strong\u003e — Statistical analysis across thousands of acquisitions for margin assessment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Interface Timing\u003c\/strong\u003e — Verify setup\/hold margins for parallel data bus against datasheet specs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClock Distribution\u003c\/strong\u003e — Measure clock-to-output delays across devices for timing budget compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with all MSO5000HD Series oscilloscopes: MSO5034HD (350 MHz), MSO5054HD (500 MHz), and MSO5104HD (1 GHz).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019153706,"sku":"191500800004","price":549.0,"currency_code":"USD","in_stock":true}]},{"product_id":"ut-gbe-ft-ethernet-compliance-test-fixture","title":"UT-GBE-FT Ethernet Compliance Test Fixture","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eUT-GBE-FT Ethernet Compliance Test Fixture. The UT-GBE-FT is a precision fixture for 10\/100\/1000BASE-T Ethernet compliance testing, designed to work with UNI-T oscilloscopes and the MSO8000HD-CT.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with UNI-T oscilloscopes\u003c\/strong\u003e — For use with UNI-T oscilloscopes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Physical Layer Testing\u003c\/strong\u003e — Precision fixture for standardized 10\/100\/1000BASE-T compliance measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeatable Measurements\u003c\/strong\u003e — Controlled impedance design for consistent, standards-traceable test results.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3 100\/1000M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100M \/ 1000M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019186474,"sku":"190100100150X","price":2939.0,"currency_code":"USD","in_stock":false}]},{"product_id":"mso5000hd-bw3m5t5m-500mhz-bandwidth-upgrade","title":"MSO5000HD-BW3M5T5M 500MHz bandwidth upgrade","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO5000HD-BW3M5T5M upgrades your MSO5034HD from 350MHz to 500MHz bandwidth — capturing faster edges and higher-frequency content without replacing the instrument. The upgrade is a software license key; the hardware already supports 500MHz.\u003c\/p\u003e\n\u003cp\u003eA 350MHz oscilloscope faithfully reproduces signals up to roughly 350MHz. Clock signals, digital buses, or switching transients with content above that are attenuated — rounded edges, reduced amplitude. Upgrading to 500MHz gives you the headroom to see what's actually happening.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e350MHz → 500MHz Bandwidth\u003c\/strong\u003e — Upgrades all analog channels on your MSO5034HD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFaster Rise Times\u003c\/strong\u003e — Higher bandwidth means accurately capturing faster edges — critical for signal integrity on high-speed interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Hardware Changes\u003c\/strong\u003e — Bandwidth is software-defined. Enter the key and operate at 500MHz immediately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInvestment Protection\u003c\/strong\u003e — Start at a lower bandwidth and unlock higher bandwidth later with a software license, as requirements grow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrowing Requirements\u003c\/strong\u003e — A new project needs more than 350MHz bandwidth. Upgrade instead of buying a new oscilloscope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Integrity\u003c\/strong\u003e — Compliance testing requires capturing fast edges accurately. The 500MHz upgrade gives you bandwidth to see the true signal shape.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis upgrade applies \u003cstrong\u003eonly\u003c\/strong\u003e to the MSO5034HD (350MHz). Not needed if your instrument already has 500MHz bandwidth or higher.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhich model does this apply to?\u003c\/h3\u003e\n\u003cp\u003eExclusively the MSO5034HD (350MHz). If your instrument already has 500MHz bandwidth or higher, this upgrade is not needed.\u003c\/p\u003e\n\u003ch3\u003eDoes bandwidth affect sample rate or memory?\u003c\/h3\u003e\n\u003cp\u003eNo. Sample rate and memory depth are unchanged. Only analog bandwidth is unlocked.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019219242,"sku":"191502500018","price":1199.0,"currency_code":"USD","in_stock":true}]},{"product_id":"utp3303-3ch-207w-32v-3a-linear-dc-power-supply","title":"UTP3303 3Ch 207W 32V\/3A Linear DC Power Supply","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UTP3303 is a 207W three-channel linear bench supply for the kind of bench work where the supply itself shouldn't need its own learning curve. Two adjustable channels deliver 0–32V at 0–3A; a third channel provides a fixed 5V at 3A for logic-level power. Knobs, banana jacks, OVP\/OCP via current-limit protection, and the kind of front panel a first-year student gets back to default settings in under 30 seconds.\u003c\/p\u003e\n\u003cp\u003eLinear regulation keeps output ripple under 1mVrms — no switching artifacts, no EMI signature competing with the circuit you're actually trying to characterize. CH1 and CH2 combine in series (up to 64V) or parallel (up to 6A), and a master-slave tracking mode keeps CH1 and CH2 synchronized when matched rails are needed for dual-supply analog work.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Channels, 207W Total\u003c\/strong\u003e — CH1 and CH2: 0–32V \/ 0–3A adjustable. CH3: fixed 5V \/ 3A for logic-level power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Topology, ≤1 mVrms Ripple\u003c\/strong\u003e — Clean DC output with no switching frequency, no harmonic spurs, and load regulation of CV ≤1×10⁻⁴ + 3 mV.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto CV\/CC Crossover with Current Limit Protection\u003c\/strong\u003e — The supply transitions automatically between constant-voltage and constant-current operation when the load steps, protecting both the DUT and the supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries and Parallel Modes\u003c\/strong\u003e — Combine CH1+CH2 for up to 64V series or 6A parallel — front-panel selectable, no external wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCH1\/CH2 Master-Slave Tracking\u003c\/strong\u003e — Tracking mode synchronizes CH1 and CH2 for matched-rail testing (op-amp ±supplies, balanced analog stages, dual-supply mixed-signal designs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Bit Voltage and Current Dual Display\u003c\/strong\u003e — Independent voltage and current readouts per channel. No menus, no hidden settings — what you see is what the channel is doing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput ON\/OFF Control\u003c\/strong\u003e — Front-panel master output button keeps you in command of when current actually leaves the supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKnob-and-Button Operation\u003c\/strong\u003e — No firmware to update, no PC software to install, no LAN port to configure. Front-panel only — designed to behave the same way on day one and year five.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eBench Power That Stays Out of the Way\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UTP3303 is the supply you put on a bench when the day's work is upstream of the power supply — circuit prototyping, board-level service, instructional labs where the lesson is signals or amplifiers, not procurement of a programmable instrument. There's no SCPI command set to learn, no firmware path to get wrong before a class starts, and no LAN configuration page to ask IT about. There's a knob, a display, and CV\/CC auto-crossover protection that doesn't need a settings menu.\u003c\/p\u003e\n\u003cp\u003eFor teaching labs and trade-school programs running 10–30 stations, this is the operational pitch: every student gets the same instrument with the same workflow, every shift. For service shops and small-team R\u0026amp;D benches, it's the supply you reach for when you don't want to think about the supply.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cdiv class=\"product-app-grid\"\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eTeaching Labs \u0026amp; Trade Schools\u003c\/h3\u003e\n\u003cp\u003ePer-station cost that lets a 20-bench classroom stay inside budget. Knob-and-button operation matches the curriculum-relevant skill: students learn measurement, not menu navigation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eAnalog Bench Development\u003c\/h3\u003e\n\u003cp\u003eDual 0–32V adjustable channels with master-slave tracking power op-amp ±supplies, audio circuits, and balanced analog front-ends from one instrument. Ripple under 1 mVrms keeps supply noise out of the measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eService \u0026amp; Repair\u003c\/h3\u003e\n\u003cp\u003eReliable everyday bench supply for board-level service work. CV\/CC auto crossover handles unknown loads safely, and the fixed 5V CH3 covers logic-level powering on legacy boards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eMaker \u0026amp; Hobbyist Workshops\u003c\/h3\u003e\n\u003cp\u003eThree-channel linear bench supply at a price that makes sense for a workshop that isn't doing automated production test. Clean output, predictable behavior, no software stack to maintain.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes the UTP3303 have USB or SCPI?\u003c\/p\u003e\n\u003cp\u003eNo. The UTP3303 is a fully analog, knob-and-button bench supply — no USB data interface, no LAN, no SCPI command set, no PC software. If your workflow needs SCPI control, the programmable counterparts in the UNI-T linear PSU family are the UDP3303C and UDP3305C (USB + RS-232) and the UDP3000S series (USB + LAN + LXI with web interface).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's the difference between the UTP3303 and the UTP3305?\u003c\/p\u003e\n\u003cp\u003eOutput current. UTP3303 delivers 0–3A on CH1 and CH2 (207W total). UTP3305 delivers 0–5A on CH1 and CH2 (335W total). Voltage range, ripple, regulation, display, and feature set are otherwise identical between the two. Choose UTP3305 if you need to source above 3A on a single rail.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhy a linear supply instead of switching?\u003c\/p\u003e\n\u003cp\u003eLinear topology produces fundamentally cleaner output — no switching frequency, no harmonic spurs, ripple under 1 mVrms. For analog bench work, audio circuits, low-noise sensor development, and any precision measurement where supply noise shows up in the result, the difference is measurable. The trade-off is lower efficiency and more heat, which at this power level on a bench is not a meaningful constraint.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's included with the UTP3303?\u003c\/p\u003e\n\u003cp\u003eThe UTP3303 ships with the instrument, power cord, output cables, English user manual Ships from authorized US dealer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUTP3303\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 (CH1, CH2 adjustable; CH3 fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH1, CH2: 0–32V\u003cbr\u003eCH3: 5V (fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH1, CH2: 0–3A\u003cbr\u003eCH3: 3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e207W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCV ≤1×10⁻⁴ + 3 mV\u003cbr\u003eCC ≤2×10⁻⁴ + 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple \u0026amp; Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage: ≤1 mVrms\u003cbr\u003eCurrent: ≤3 mArms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Regulation Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCV: 100 mV (typical)\u003cbr\u003eCC: 10 mA (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTracking Bias (CH1\/CH2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5×10⁻³ + 10 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-bit voltage and current dual display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndependent, Series, Parallel, CH1\/CH2 Master-Slave Tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent limit protection with auto CV\/CC crossover, output ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReliability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMTBF ≥ 2,000 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V \/ 230V AC, 47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e260 × 170 × 315 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=43\"\u003eUTP3303 Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019252010,"sku":"181730090200X","price":210.0,"currency_code":"USD","in_stock":true}]},{"product_id":"mso5000hd-mil1553-mil-std-1553-serial-bus-trigger-and-analysis-option","title":"MSO5000HD-MIL1553 MIL-STD-1553 Serial Bus Trigger and Analysis Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO5000HD-MIL1553 adds MIL-STD-1553 protocol triggering, decoding, and search to your MSO5000HD Series oscilloscope — the primary command\/response bus for military avionics, weapons systems, and spacecraft.\u003c\/p\u003e\n\u003cp\u003eOperating at 1 Mbit\/s over redundant twisted pair, 1553 is in virtually every military aircraft. Protocol-level visibility overlaid on the electrical waveform for debugging timing and signal integrity simultaneously. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1553 Triggering\u003c\/strong\u003e — Trigger on command\/status\/data words, RT addresses, subaddresses, or errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommand\/Response Decoding\u003c\/strong\u003e — Decoded transactions on the waveform — command word, status word, data words with RT address and word count.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time Measurement\u003c\/strong\u003e — Measures RT response time for compliance verification (4-12 µs requirement).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eError Detection\u003c\/strong\u003e — Identifies sync, Manchester encoding, parity, and timeout errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRT Development\u003c\/strong\u003e — Verify your remote terminal responds within the 4-12 µs window with correct status word content.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy System Maintenance\u003c\/strong\u003e — Search deep captures for intermittent 1553 errors, then examine the waveform for electrical root causes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with all MSO5000HD Series oscilloscopes: MSO5034HD (350 MHz), MSO5054HD (500 MHz), and MSO5104HD (1 GHz). The same capability is offered on other UNI-T oscilloscope families: MSO3000HD, MSO3000X.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eShould I buy this individually or get a bundle?\u003c\/h3\u003e\n\u003cp\u003eIf you only need MIL-STD-1553, the individual license covers exactly that protocol. The BND bundle includes every protocol in the series.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019317546,"sku":"191502800008","price":279.0,"currency_code":"USD","in_stock":true}]},{"product_id":"mso5000hd-manch-manchester-serial-bus-trigger-and-analysis-option","title":"MSO5000HD-MANCH Manchester Serial Bus Trigger and Analysis Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO5000HD-MANCH adds Manchester encoding trigger and decode to your MSO5000HD Series oscilloscope — a self-clocking line code used in 10BASE-T Ethernet, RFID, NFC, and industrial protocols.\u003c\/p\u003e\n\u003cp\u003eDecodes data content directly on screen, saving manual transition interpretation. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManchester Decode\u003c\/strong\u003e — Decodes Manchester and Differential Manchester data with bit values on the waveform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Parameters\u003c\/strong\u003e — Set bit rate, idle polarity, and convention (IEEE 802.3 or G.E. Thomas).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePattern Triggering\u003c\/strong\u003e — Trigger on specific data patterns in the encoded stream.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eError Detection\u003c\/strong\u003e — Identifies encoding violations at mid-bit boundaries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRFID Debug\u003c\/strong\u003e — Decode reader-to-tag and tag-to-reader Manchester communication for command\/response verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Sensor\u003c\/strong\u003e — Custom sensor uses Manchester encoding. Decode to verify data content and timing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with all MSO5000HD Series oscilloscopes: MSO5034HD (350 MHz), MSO5054HD (500 MHz), and MSO5104HD (1 GHz). The same capability is offered on other UNI-T oscilloscope families: MSO3000HD, MSO3000X, MSO8000HD.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eShould I buy this individually or get a bundle?\u003c\/h3\u003e\n\u003cp\u003eIf you only need Manchester, the individual license covers exactly that protocol. The BND bundle includes every protocol in the series.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019350314,"sku":"191502400035","price":279.0,"currency_code":"USD","in_stock":true}]},{"product_id":"upo2000hd-bw7t2m-bandwidth-upgrade-to-200mhz","title":"UPO2000HD-BW7T2M Bandwidth Upgrade to 200MHz","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UPO2000HD-BW7T2M upgrades your UPO2072HD from 70MHz to 200MHz bandwidth — capturing faster edges and higher-frequency content without replacing the instrument. The upgrade is a software license key; the hardware already supports 200MHz.\u003c\/p\u003e\n\u003cp\u003eA 70MHz oscilloscope faithfully reproduces signals up to roughly 70MHz. Clock signals, digital buses, or switching transients with content above that are attenuated — rounded edges, reduced amplitude. Upgrading to 200MHz gives you the headroom to see what's actually happening.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e70MHz → 200MHz Bandwidth\u003c\/strong\u003e — Upgrades all analog channels on your UPO2072HD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFaster Rise Times\u003c\/strong\u003e — Higher bandwidth means accurately capturing faster edges — critical for signal integrity on high-speed interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Hardware Changes\u003c\/strong\u003e — Bandwidth is software-defined. Enter the key and operate at 200MHz immediately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInvestment Protection\u003c\/strong\u003e — Start at a lower bandwidth and unlock higher bandwidth later with a software license, as requirements grow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrowing Requirements\u003c\/strong\u003e — A new project needs more than 70MHz bandwidth. Upgrade instead of buying a new oscilloscope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Integrity\u003c\/strong\u003e — Compliance testing requires capturing fast edges accurately. The 200MHz upgrade gives you bandwidth to see the true signal shape.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis upgrade applies \u003cstrong\u003eonly\u003c\/strong\u003e to the UPO2072HD (70MHz). Not needed if your instrument already has 200MHz bandwidth or higher.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhich model does this apply to?\u003c\/h3\u003e\n\u003cp\u003eExclusively the UPO2072HD (70MHz). If your instrument already has 200MHz bandwidth or higher, this upgrade is not needed.\u003c\/p\u003e\n\u003ch3\u003eDoes bandwidth affect sample rate or memory?\u003c\/h3\u003e\n\u003cp\u003eNo. Sample rate and memory depth are unchanged. Only analog bandwidth is unlocked.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019284778,"sku":"191502500015","price":552.0,"currency_code":"USD","in_stock":true}]},{"product_id":"ut-pd2500-2-5-ghz-active-differential-probe","title":"UT-PD2500 2.5 GHz Active Differential Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e2.5 GHz active differential oscilloscope probe with 10:1 attenuation and ±4V dynamic range. High-bandwidth differential measurement for power electronics, high-speed serial links, and switched-mode converter analysis. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5GHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 2.5GHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10:1 Attenuation\u003c\/strong\u003e — Divides the input signal for measuring higher-voltage circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e±4 V Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019383082,"sku":"190500400010X","price":3779.0,"currency_code":"USD","in_stock":true}]},{"product_id":"ut-z042-standard-lens-for-uni-t-uti760x-thermal-imager","title":"UT-Z042 Standard Lens for UNI-T UTI760X Thermal Imager","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e18mm Standard lens for UTI760X thermal cameras (24°x 19.3° FOV). General-purpose replacement or upgrade lens for everyday industrial and building inspection work.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eStandard lens. Lens: 18mm — F\/1.0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFOV: 24°x 19.3°\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIFOV: 0.66mard\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMin Imaging Distance: 0.15m\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Lens Recognition\u003c\/strong\u003e — Camera detects the lens and adjusts calibration automatically for accurate temperature readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigned for UTi760X thermal camera\u003c\/strong\u003e — See the UTi760X thermal camera product page for full camera specifications. Camera sold separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFocal Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019415850,"sku":"121500200069X","price":1449.0,"currency_code":"USD","in_stock":true}]},{"product_id":"utl1020s-200w-high-resolution-programmable-dc-electronic-load","title":"UTL1020S 200W High-Resolution Programmable DC Electronic Load","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTL1020S\u003c\/strong\u003e is a single-channel programmable DC electronic load rated 200 W, 0–150 V, 0–30 A. It runs four constant modes — CC, CV, CR, CP — plus eleven additional test modes including dynamic, OVP, OCP, time, CR-LED, battery, automatic list, short-circuit, load-effect, combination, and list, for 15 test modes in total. Synchronous sampling reaches 500 kHz with high-performance DSP processing and a self-adaptive voltage and current waveform display on the 4.3-inch TFT LCD.\u003c\/p\u003e\n\u003cp\u003eDynamic mode pulls load at up to 50 kHz so current and voltage peaks — Vpp and Ipp — can be observed directly. The load also provides on-screen ripple measurement, a rear-panel Sense terminal for remote voltage compensation, and SCPI remote control over RS232 with a HANDLER interface and USB Host port for data logging and automated production test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eChoosing Your Model — 200 W 15-Mode Load\u003c\/h2\u003e\n\u003cp\u003eTwo 200 W models share the same load architecture, the same 15 test modes, the same accuracy class, and the same 0–150 V \/ 0–30 A input envelope. They differ in one axis only: measurement resolution.\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUTL1020S\u003c\/strong\u003e (high-resolution)\u003c\/td\u003e\n\u003ctd\u003eCurrent resolution 0.01 mA \/ 0.1 mA, voltage readback 0.01 mV \/ 0.1 mV — finer metering for precision readback work.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUTL1020S-E\u003c\/strong\u003e (standard resolution)\u003c\/td\u003e\n\u003ctd\u003eSame 200 W load, same 15 modes; current resolution 0.1 mA \/ 1 mA, voltage readback 0.1 mV \/ 1 mV. The lower-cost choice when fine readback resolution is not the deciding factor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eThis page describes the \u003cstrong\u003eUTL1020S\u003c\/strong\u003e. Capability, test modes, protection, and interfaces below apply to both 200 W models; the Specifications table lists this model's resolution figures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 W, 0–150 V, 0–30 A single-channel load\u003c\/strong\u003e — CC, CV, CR, CP basic modes with dual high\/low input ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15 test modes\u003c\/strong\u003e — CC, CV, CR, CP, dynamic, OVP, time, OCP, CR-LED, battery, automatic list, short circuit, load effect, combination, list.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 kHz synchronous sampling\u003c\/strong\u003e — high sampling density for accurate transient capture and reduced measurement omission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e50 kHz dynamic mode\u003c\/strong\u003e — programmable rise\/fall slope (0.0006–3 A\/µs) simulates real changing load conditions; Vpp \/ Ipp observed directly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery test with charge and discharge curves\u003c\/strong\u003e — records both charge and discharge curves for battery characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic list test\u003c\/strong\u003e — up to 200-step programmable multi-mode sequences for automated, repeatable testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-screen ripple measurement and real-time waveform\u003c\/strong\u003e — ripple readout in the screen corner; [WAVE] key shows live V\/I waveform without an external oscilloscope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote compensation (Sense terminal)\u003c\/strong\u003e — rear-panel Sense terminal eliminates lead voltage-drop error at high current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS232 \/ USB Host \/ HANDLER, SCPI protocol\u003c\/strong\u003e — PC software control, USB-drive screenshots and list import\/export, HANDLER for ATE integration.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCurrent resolution 0.01 mA \/ 0.1 mA, voltage readback 0.01 mV \/ 0.1 mV, 16-bit CR, 3 years standard + 2 year extension.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTL1020S Details\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e15 Test Modes for Power, Battery, and LED-Driver Validation\u003c\/h3\u003e\n\u003cp\u003eFour constant modes — CC (constant current), CV (constant voltage), CR (constant resistance), CP (constant power) — plus eleven more: dynamic, OVP, time, OCP, CR-LED, battery, automatic list, short-circuit, load effect, combination, and list. The CR-LED mode simulates real LED forward-voltage behavior for LED-driver testing; battery mode records charge and discharge curves; combination mode pairs two basic modes (CR+CC, CV+CR, CV+CC) for more realistic DUT conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_test-modes_sq.jpg?v=1770678169\" alt=\"UTL1020S 15 test modes covering power, battery, and LED-driver validation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e15 Test Modes for Power, Battery, and LED-Driver Validation\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_dynamic-testing_sq.jpg?v=1770678169\" alt=\"UTL1020S dynamic mode 50 kHz transient load simulation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eDynamic Mode — 50 kHz Transient Load Simulation\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eDynamic Mode — 50 kHz Transient Load Simulation\u003c\/h3\u003e\n\u003cp\u003eDynamic mode pulls load at frequencies up to 50 kHz with T1\/T2 timing from 10 µs to 50 s (1 µs resolution) and a programmable rising\/falling current slope of 0.0006 A\/µs to 3 A\/µs. The current and voltage peak waveforms are observed directly on screen with Vpp and Ipp measurement, so transient response and overshoot of the device under test can be characterized without a separate oscilloscope.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eBattery Test with Charge and Discharge Curves\u003c\/h3\u003e\n\u003cp\u003eBattery mode performs constant-current or constant-power discharge testing and records the full discharge curve. The UTL1020S captures both the discharge and the charging curve, so capacity, internal-resistance behavior, and cycle characteristics are traceable from a single instrument — useful for battery-pack, BMS, and power-bank validation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_battery-testing.gif\" alt=\"UTL1020S battery test recording charge and discharge curves\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBattery Test with Charge and Discharge Curves\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_auto-list.gif\" alt=\"UTL1020S automatic list test with up to 200 programmable steps\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eAutomatic List Test — 200-Step Programmable Sequences\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eAutomatic List Test — 200-Step Programmable Sequences\u003c\/h3\u003e\n\u003cp\u003eThe automatic list test runs editable multi-step, multi-mode sequences with up to 200 steps. Set the appropriate load value and mode for each step and the list executes the full test process automatically. List files save to internal memory or a USB drive and can be imported, so a validated production-test sequence transfers between units quickly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eOn-Screen Ripple Measurement and Real-Time Waveform\u003c\/h3\u003e\n\u003cp\u003eRipple is measured and displayed directly in the corner of the screen, replacing a separate oscilloscope measurement for routine power-supply ripple checks. Pressing the [WAVE] function key shows the live voltage and current waveform, with the self-adaptive display scaling automatically to the signal.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_ripple-measurement_sq.jpg?v=1770678169\" alt=\"UTL1020S on-screen ripple measurement and real-time waveform display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eOn-Screen Ripple Measurement and Real-Time Waveform\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_ovp_sq.jpg?v=1770678169\" alt=\"UTL1020S OVP and OCP protection-function testing\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eOVP and OCP Protection Testing\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eOVP and OCP Protection Testing\u003c\/h3\u003e\n\u003cp\u003eSet the protection threshold according to the device under test and the UTL1020S measures the protection function and the protection response time. Overvoltage protection triggers with delayed protection at ≥ 152 V and immediate protection at ≥ 165 V; overcurrent protection at ≥ 30.3 A delayed and ≥ 33 A immediate; overpower at ≥ 202 W delayed and ≥ 220 W immediate. Instrument protection can also be turned off to prevent false alarms during characterization.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eLoad Effect Test\u003c\/h3\u003e\n\u003cp\u003eThe load effect test automatically measures and calculates load-regulation results from the configured test values, so power-supply load regulation is characterized without manual point-by-point measurement and calculation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_load-effect-test_sq.jpg?v=1770678169\" alt=\"UTL1020S automated load effect \/ load regulation test\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eLoad Effect Test\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_time-test_sq.jpg?v=1770678169\" alt=\"UTL1020S time test measuring power-supply rise and fall time\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eTime Test — Rise and Fall Time of the Power Supply\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eTime Test — Rise and Fall Time of the Power Supply\u003c\/h3\u003e\n\u003cp\u003eTime test measures the rise and fall times of the device under test against configured thresholds, with 1 µs timing resolution and ±100 ppm timing accuracy, for power-supply turn-on \/ turn-off and transient-timing characterization.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe 200 W 15-mode envelope — CC\/CV\/CR\/CP plus dynamic, battery, list, protection, load-effect, and combination modes with 500 kHz sampling — covers R\u0026amp;D and production test for power electronics.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching power-supply and adapter test\u003c\/strong\u003e — load regulation, ripple, transient response, and protection-function verification from one instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery and battery-pack characterization\u003c\/strong\u003e — charge and discharge curve recording for capacity, BMS, and cycle testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED-driver validation\u003c\/strong\u003e — CR-LED mode simulates real LED forward-voltage behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger and power-bank testing\u003c\/strong\u003e — automatic list sequences for repeatable multi-step production test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC-DC converter and module test\u003c\/strong\u003e — dynamic loading at up to 50 kHz to characterize transient overshoot and recovery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated production test (ATE)\u003c\/strong\u003e — SCPI over RS232 plus HANDLER interface for test-line integration; list import\/export for fast line setup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003ch3\u003eIncluded with Every Unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC power cord\u003c\/li\u003e\n\u003cli\u003eRS232 communication cable\u003c\/li\u003e\n\u003cli\u003ePlug-in terminal block (5.08-2P) and screw-free spring terminal block (2.54-6P)\u003c\/li\u003e\n\u003cli\u003eSpare fuse (2 pcs)\u003c\/li\u003e\n\u003cli\u003eCertificate of calibration and multi-language safety precautions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional Test Leads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0615-OO\u003c\/strong\u003e — double O-type terminal, 60 A \/ 1.5 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0320-UU\u003c\/strong\u003e — double U-type terminal, 30 A \/ 2 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0312-UU\u003c\/strong\u003e — double U-type terminal, 30 A \/ 1.2 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0110-BB\u003c\/strong\u003e — double fold-insert, 10 A \/ 1 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0110-BU\u003c\/strong\u003e — fold-insert to U-type, 10 A \/ 1 m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUTL1000S Series\u003c\/h3\u003e\n\u003cp\u003eFour models share the same chassis, 15 test modes, 500 kHz sampling, accuracy class, and 0–150 V \/ 0–30 A input envelope:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTL1020S\u003c\/strong\u003e — 200 W, high-resolution (this product)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTL1020S-E\u003c\/strong\u003e — 200 W, standard resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTL1040S\u003c\/strong\u003e — 400 W, high-resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTL1040S-E\u003c\/strong\u003e — 400 W, standard resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the difference between the UTL1020S and the UTL1020S-E?\u003c\/p\u003e\n\u003cp\u003eBoth are 200 W loads with the same 15 test modes, the same accuracy class, and the same 0–150 V \/ 0–30 A input envelope. The difference is measurement resolution: the UTL1020S resolves current to 0.01 mA \/ 0.1 mA and voltage readback to 0.01 mV \/ 0.1 mV across its low and high ranges. The high-resolution model is suited to precision readback work; the standard-resolution model is the lower-cost choice when fine readback resolution is not the deciding factor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow many test modes does the UTL1020S have, and what are they?\u003c\/p\u003e\n\u003cp\u003e15 modes: CC, CV, CR, CP, dynamic, OVP, time, OCP, CR-LED, battery, automatic list, short circuit, load effect, combination, list. The four constant modes (CC, CV, CR, CP) cover standard load testing; the remaining modes add transient, protection, battery, LED-driver, automated, and combination testing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan the UTL1020S test batteries?\u003c\/p\u003e\n\u003cp\u003eYes. Battery mode performs discharge testing and records both the discharge and the charging curve, so capacity and cycle behavior are traceable from the instrument — useful for battery-pack, BMS, and power-bank validation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes it measure ripple without an oscilloscope?\u003c\/p\u003e\n\u003cp\u003eYes. Ripple is measured and displayed in the corner of the screen, and the [WAVE] key shows the live voltage and current waveform, so routine ripple and waveform checks do not require a separate oscilloscope.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the Sense terminal for?\u003c\/p\u003e\n\u003cp\u003eAt high current, lead resistance creates a voltage drop between the load and the device under test. The rear-panel Sense terminal measures voltage at the DUT output terminal directly (remote compensation), so the displayed voltage reflects the DUT rather than the voltage after the test leads.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow is the UTL1020S controlled remotely?\u003c\/p\u003e\n\u003cp\u003eOver RS232 using the standard SCPI protocol with the included PC data-acquisition software. A HANDLER interface supports automated test-line integration, and a USB Host port accepts a USB drive for screenshots and for importing or exporting list files.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_test-modes_sq.jpg?v=1770678169\" alt=\"UTL1020S 15 test modes covering power, battery, and LED-driver validation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e15 Test Modes for Power, Battery, and LED-Driver Validation\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_dynamic-testing_sq.jpg?v=1770678169\" alt=\"UTL1020S dynamic mode 50 kHz transient load simulation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eDynamic Mode — 50 kHz Transient Load Simulation\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_battery-testing.gif\" alt=\"UTL1020S battery test recording charge and discharge curves\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBattery Test with Charge and Discharge Curves\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_auto-list.gif\" alt=\"UTL1020S automatic list test with up to 200 programmable steps\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eAutomatic List Test — 200-Step Programmable Sequences\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_ripple-measurement_sq.jpg?v=1770678169\" alt=\"UTL1020S on-screen ripple measurement and real-time waveform display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eOn-Screen Ripple Measurement and Real-Time Waveform\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_ovp_sq.jpg?v=1770678169\" alt=\"UTL1020S OVP and OCP protection-function testing\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eOVP and OCP Protection Testing\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_load-effect-test_sq.jpg?v=1770678169\" alt=\"UTL1020S automated load effect \/ load regulation test\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eLoad Effect Test\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_time-test_sq.jpg?v=1770678169\" alt=\"UTL1020S time test measuring power-supply rise and fall time\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eTime Test — Rise and Fall Time of the Power Supply\u003c\/span\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput power (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–15 V (low) \/ 0–150 V (high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–3 A (low) \/ 0–30 A (high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum operating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 V ± 0.1 V at 30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCV mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange 0.1–150 V, resolution 1 mV, accuracy ±(0.03% + 0.05% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCC mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResolution 0.01 mA \/ 0.1 mA (low \/ high), accuracy ±(0.03% + 0.05% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCR mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange 0.05 Ω – 10 kΩ, resolution 16 bits, accuracy (0.1 + 0.01R)%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCP mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange 200 W, resolution 10 mW, accuracy ±(0.1% + 0.1% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadback voltage resolution (CC\/CP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mV \/ 0.1 mV (low \/ high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadback voltage resolution (CV\/CR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadback current resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mA \/ 0.1 mA (low \/ high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadback accuracy (V \/ I \/ P)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(0.02% + 0.3% FS) \/ ±(0.03% + 0.05% FS) \/ ±(0.1% + 0.1% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic mode T1 \u0026amp; T2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 µs – 50 s, 1 µs resolution; timing accuracy 1 µs \/ 1 ms ±100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic rise\/fall slope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0006 A\/µs – 3 A\/µs (min. rise time 10 µs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSynchronous sampling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 kHz synchronous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverpower protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDelay ≥ 202 W, immediate ≥ 220 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercurrent protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDelay ≥ 30.3 A, immediate ≥ 33 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDelay ≥ 152 V, immediate ≥ 165 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver-temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit (CC \/ CV \/ CR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 30 A \/ 0 V \/ 60 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15: CC, CV, CR, CP, dynamic, OVP, time, OCP, CR-LED, battery, automatic list, short circuit, load effect, combination, list\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple display \/ waveform record\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes \/ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput terminal impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A (110 V) \/ 0.25 A (220 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232, USB Host, HANDLER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3-inch TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 V \/ 220 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e215 × 88 × 372 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.73 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C – 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy temperature \/ calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 ± 5 °C \/ 1 \/ year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_Series_DC_Electronic_Load_-_Data_Sheet.pdf?v=1772202746\"\u003eUTL1020S Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_Series_DC_Electronic_Load_-_Manuals.zip?v=1772202727\"\u003eUTL1020S User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019448618,"sku":"181500100145X","price":599.0,"currency_code":"USD","in_stock":true}]},{"product_id":"ut-pr2060-1-ghz-low-noise-power-rail-probe","title":"UT-PR2060 1 GHz Low-Noise Power Rail Probe","description":"","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019481386,"sku":"190500100164X","price":3779.0,"currency_code":"USD","in_stock":false}]},{"product_id":"uti740ms-smartphone-thermal-camera-for-ios-and-android","title":"UTi740MS Smartphone Thermal Camera for iOS and Android","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTi740MS Smartphone Thermal Camera\u003c\/h2\u003e\n\n\u003ch3\u003eHigh-Resolution Thermal Imaging with Smartphone Connectivity\u003c\/h3\u003e\n\n\u003cp\u003eThe UNI-T UTi740MS is a professional-grade thermal imaging camera that transforms your smartphone into a powerful diagnostic tool. Featuring an exceptional 400×300 pixel IR detector with Super Resolution technology that enhances images to 800×600 pixels, this compact device delivers crisp, detailed thermal images for precise diagnostics. With manual focus capability, high thermal sensitivity (≤45mK), and a wide temperature range (-20°C to 550°C), the UTi740MS provides the performance needed by maintenance professionals, home inspectors, HVAC technicians, and electrical contractors. The plug-and-play USB-C connection and dedicated mobile app make professional thermal imaging more accessible and portable than ever.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Imaging\u003c\/strong\u003e: 400×300 pixel IR detector with Super Resolution technology enhancing images to 800×600 pixels\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuperior Thermal Sensitivity\u003c\/strong\u003e: ≤45mK @25°C for detecting subtle temperature differences\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManual Focus Capability\u003c\/strong\u003e: Adjustable focus for clear imaging at various distances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Temperature Range\u003c\/strong\u003e: Measures from -20°C to 550°C with ±2°C or ±2% accuracy\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSmartphone Integration\u003c\/strong\u003e: Direct connection to Android and iOS devices via Type-C USB interface\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDedicated Mobile App\u003c\/strong\u003e: \"Thermal Mobile\" app for enhanced analysis and reporting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive Analysis Tools\u003c\/strong\u003e: 5 Points\/1 Line\/3 Rectangles\/3 Circles measurement options\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMultiple Isotherm Modes\u003c\/strong\u003e: Auto\/Below\/Above\/Section\/Manual modes for targeted analysis\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLightweight Design\u003c\/strong\u003e: Approximately 46g with compact dimensions (58mm×27mm×28.6mm)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVideo Recording\u003c\/strong\u003e: Capture and save thermal videos in MP4 format\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery-Free Operation\u003c\/strong\u003e: Powered directly through smartphone connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eProfessional-Grade Thermal Imaging in Your Pocket\u003c\/h3\u003e\n\n\u003cp\u003eThe UNI-T UTi740MS delivers exceptional thermal imaging performance in an ultra-portable format. With its 400×300 pixel native resolution and Super Resolution enhancement to 800×600 pixels, it provides four times more detail than standard smartphone thermal cameras. The high thermal sensitivity of ≤45mK allows detection of minimal temperature variations, essential for identifying potential issues before they become critical failures.\u003c\/p\u003e\n\n\u003cp\u003eThe manual focus design allows technicians to adjust the focal point precisely, ensuring sharp imaging from various distances and across different applications. This capability is critical for accurate temperature readings and detailed thermal analysis across diverse inspection scenarios, from small electronic components to large building structures.\u003c\/p\u003e\n\n\u003ch3\u003eSmartphone Integration for Maximum Portability\u003c\/h3\u003e\n\n\u003cp\u003eUnlike traditional thermal cameras that require dedicated screens and batteries, the UTi740MS integrates directly with your smartphone via USB-C connection, creating a truly portable thermal imaging solution. The plug-and-play design eliminates the need for batteries or charging, while the lightweight construction (just 46g) makes it easy to carry in a pocket or toolkit.\u003c\/p\u003e\n\n\u003cp\u003eThe dedicated \"Thermal Mobile\" app transforms your smartphone into a professional thermal analysis platform with intuitive controls and comprehensive measurement tools. This integration leverages your smartphone's processing power and display for enhanced analysis and simplified sharing of thermal data, images, and reports with clients or team members.\u003c\/p\u003e\n\n\u003ch3\u003eComprehensive Measurement Capabilities\u003c\/h3\u003e\n\n\u003cp\u003eThe UTi740MS combines essential thermal imaging with specialized measurement functions to deliver complete diagnostic capabilities. Beyond standard temperature visualization, it offers:\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eMultiple measurement points and zones for comparative analysis\u003c\/li\u003e\n  \u003cli\u003eFive different isotherm modes for focused temperature range visualization\u003c\/li\u003e\n  \u003cli\u003eHigh\/low temperature tracking and alarms\u003c\/li\u003e\n  \u003cli\u003eVideo recording for documenting temperature changes over time\u003c\/li\u003e\n  \u003cli\u003eProfessional report generation directly from the app\u003c\/li\u003e\n  \u003cli\u003eTemperature measurement in both industrial mode and elevated skin temperature (EST) screening mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe dual measurement modes provide versatility for both industrial applications (with standard ±2°C or ±2% accuracy) and human temperature screening applications (with enhanced ±0.5°C accuracy in the 20°C-50°C range), making the UTi740MS a multi-purpose diagnostic tool.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhich smartphones are compatible with the UTi740MS?\u003c\/p\u003e\n\u003cp\u003eThe UTi740MS connects via USB-C and is compatible with Android smartphones. Some models also support iOS via Lightning connector. Check the specifications tab for detailed compatibility requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDo I need to install an app?\u003c\/p\u003e\n\u003cp\u003eYes. UNI-T provides a free companion app for thermal image viewing, analysis, and reporting. The app is available on the Google Play Store and Apple App Store.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's included with the UTi740MS?\u003c\/p\u003e\n\u003cp\u003eThe UTi740MS ships with the thermal camera module, carrying pouch, and user manual. A smartphone is required (not included).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIR Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400×300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNETD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 45mK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C (-4 °F) to 550 °C (1022 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±2 °C or ±2% (whichever greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29° × 21.5°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectral Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 - 14µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePixel Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefresh Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpatial Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.26mrad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFocus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual Focus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuper Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImage Blending\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsotherm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImage Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal, T-Mix fusion, PIP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImage Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRadiometric JPEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMP4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn Screen Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Points\/1 Lines\/3 Rectangles\/3 Circles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAndroid, iOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Type-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLanguages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnglish, Simplified Chinese, French, German, Italian, Spanish, Swedish, Polish, Czech\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e46 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58 × 27 × 28.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Thermal%20Camera%20Datasheets\/UTi740MS%20Data%20Sheet.pdf\"\u003eUTi740MS Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Thermal%20Camera%20User%20Manuals\/UTi740MS_User_Manual.pdf\"\u003eUTi740MS User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019546922,"sku":"180700100279X","price":799.0,"currency_code":"USD","in_stock":true}]},{"product_id":"ut-m26-16ch-logic-analyzer-probe-for-mso1000hd-series","title":"UT-M26 16Ch Logic Analyzer Probe for MSO1000HD Series","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e16-channel logic analyzer probe pod for MSO1000HD Series. Adds digital bus visibility for mixed-signal debugging of embedded, automotive, and industrial protocols. Connects to compatible UNI-T oscilloscopes via the dedicated logic analyzer port.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Connects to compatible UNI-T oscilloscopes via the dedicated logic analyzer port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Channels\u003c\/strong\u003e — Adds digital bus visibility for debugging embedded, automotive, and industrial communication protocols.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e — Compatible with UNI-T MSO1000HD ONLY.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C - 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 pF ±1 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e101 kΩ ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin Pulse Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwing Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mV - ±20 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019514154,"sku":"191000100027X","price":419.0,"currency_code":"USD","in_stock":true}]},{"product_id":"mso5000hd-bw3m5t1g-1ghz-bandwidth-upgrade","title":"MSO5000HD-BW3M5T1G 1GHz bandwidth upgrade","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO5000HD-BW3M5T1G upgrades your MSO5034HD from 350MHz to 1GHz bandwidth — capturing faster edges and higher-frequency content without replacing the instrument. The upgrade is a software license key; the hardware already supports 1GHz.\u003c\/p\u003e\n\u003cp\u003eA 350MHz oscilloscope faithfully reproduces signals up to roughly 350MHz. Clock signals, digital buses, or switching transients with content above that are attenuated — rounded edges, reduced amplitude. Upgrading to 1GHz gives you the headroom to see what's actually happening.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e350MHz → 1GHz Bandwidth\u003c\/strong\u003e — Upgrades all analog channels on your MSO5034HD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFaster Rise Times\u003c\/strong\u003e — Higher bandwidth means accurately capturing faster edges — critical for signal integrity on high-speed interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Hardware Changes\u003c\/strong\u003e — Bandwidth is software-defined. Enter the key and operate at 1GHz immediately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInvestment Protection\u003c\/strong\u003e — Start at a lower bandwidth and unlock higher bandwidth later with a software license, as requirements grow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrowing Requirements\u003c\/strong\u003e — A new project needs more than 350MHz bandwidth. Upgrade instead of buying a new oscilloscope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Integrity\u003c\/strong\u003e — Compliance testing requires capturing fast edges accurately. The 1GHz upgrade gives you bandwidth to see the true signal shape.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis upgrade applies \u003cstrong\u003eonly\u003c\/strong\u003e to the MSO5034HD (350MHz). Not needed if your instrument already has 1GHz bandwidth or higher.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhich model does this apply to?\u003c\/h3\u003e\n\u003cp\u003eExclusively the MSO5034HD (350MHz). If your instrument already has 1GHz bandwidth or higher, this upgrade is not needed.\u003c\/p\u003e\n\u003ch3\u003eDoes bandwidth affect sample rate or memory?\u003c\/h3\u003e\n\u003cp\u003eNo. Sample rate and memory depth are unchanged. Only analog bandwidth is unlocked.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019579690,"sku":"191502500017","price":3199.0,"currency_code":"USD","in_stock":true}]},{"product_id":"ut-ck02-utility-kit","title":"UT-CK02 Utility Kit","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eConnector and cable kit for integrating UNI-T spectrum analyzers into RF test setups. Includes commonly needed adapters and interconnects.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with UNI-T spectrum analyzers\u003c\/strong\u003e — For use with UNI-T spectrum analyzers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetails\u003c\/strong\u003e — UT-W03-40GHz (1pc),UT-C04-40GHz(2pcs),UT-C03-18GHz (1pc).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019612458,"sku":"191700100006X","price":389.0,"currency_code":"USD","in_stock":true}]},{"product_id":"mso5000hd-flex-automotive-flexray-serial-bus-trigger-and-analysis","title":"MSO5000HD-FLEX Automotive FlexRay Serial Bus Trigger and Analysis","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO5000HD-FLEX adds FlexRay protocol triggering, decoding, and search to your MSO5000HD Series oscilloscope. FlexRay is a deterministic, fault-tolerant bus for safety-critical chassis control, braking, and drive-by-wire applications.\u003c\/p\u003e\n\u003cp\u003eFlexRay provides dual-channel redundancy and guaranteed time slots for critical messages. This option overlays decoded protocol content on the physical signal for debugging timing and electrical issues simultaneously. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexRay Triggering\u003c\/strong\u003e — Trigger on frame ID, cycle count, payload data, indicator bits, null frames, or errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Frame Decoding\u003c\/strong\u003e — Decoded frames display with ID, payload, header CRC, and cycle info alongside the analog signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic\/Dynamic Segment Visibility\u003c\/strong\u003e — Identifies static vs. dynamic segment frames for schedule table verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeep Memory Search\u003c\/strong\u003e — Search acquisitions for specific frame IDs, data patterns, or errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Control Debug\u003c\/strong\u003e — Verify FlexRay timing in electronic suspension — trigger on static slots and check both protocol timing and signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Validation\u003c\/strong\u003e — Capture both Channel A and B to verify redundant message consistency and failover.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with all MSO5000HD Series oscilloscopes: MSO5034HD (350 MHz), MSO5054HD (500 MHz), and MSO5104HD (1 GHz). The same capability is offered on other UNI-T oscilloscope families: MSO2000X, MSO3000HD, MSO3000X, MSO7000X, MSO8000HD, UPO7000L.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eShould I buy this individually or get a bundle?\u003c\/h3\u003e\n\u003cp\u003eIf you only need FlexRay, the individual license covers exactly that protocol. The AUTO bundle adds the automotive protocols in one license. The BND bundle includes every protocol in the series.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019710762,"sku":"191501400045","price":279.0,"currency_code":"USD","in_stock":true}]},{"product_id":"utx325m-infrared-long-distance-thermal-monocular","title":"UTx325M Infrared Long-Distance Thermal Monocular","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003ch3\u003e\u003cstrong\u003eUTx325M\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003eLong-Range Precision for Professionals\u003c\/h4\u003e\n\u003cp\u003eMeet the UTx325M—an advanced thermal monocular built for professionals who demand the best. From long-range wildlife tracking to high-stakes search and rescue missions, this device offers unmatched accuracy and performance.\u003c\/p\u003e\n\u003cp\u003eThe UTx325M is equipped with a 25mm lens, making it ideal for long-distance detection and identification. Its precision thermal imaging ensures you can detect heat signatures even in challenging conditions, whether it's navigating dense forests or monitoring expansive perimeters.\u003c\/p\u003e\n\u003cp\u003eThe UTx325M features stadiametric ranging for estimating distances quickly and accurately. Unlike laser range finding, which provides exact measurements, stadiametric ranging relies on an intuitive scaling method for objects of known size, offering speed and convenience without additional hardware. This feature is invaluable for professionals needing rapid situational awareness in dynamic scenarios.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIR Resolution\u003c\/strong\u003e: 400×300 pixels for crystal-clear imaging\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLens Focal Length\u003c\/strong\u003e: 25mm for superior long-range performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Sensitivity\u003c\/strong\u003e: ≤25mK for detecting subtle temperature variations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField of View (FOV)\u003c\/strong\u003e: 10.5° × 7.9° for precise long-range scanning\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange Finding\u003c\/strong\u003e: Stadiametric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life\u003c\/strong\u003e: 6+ hours for extended use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurability\u003c\/strong\u003e: IP67 waterproof and drop-resistant up to 2 meters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Features\u003c\/strong\u003e: Hot Trace, Wi-Fi Live Streaming\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the detection range of the UTx325M?\u003c\/p\u003e\n\u003cp\u003eDetection range depends on the target size and thermal contrast. The UTx325M's specifications list the maximum detection range for a standard 1.7m × 0.5m target. Actual usable range for identification is typically 30-50% of the maximum detection distance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the UTx325M waterproof?\u003c\/p\u003e\n\u003cp\u003eThe UTx325M carries an IP rating for dust and water resistance. Check the specifications tab for the exact IP rating. The device is designed for outdoor use in varying weather conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's included with the UTx325M?\u003c\/p\u003e\n\u003cp\u003eThe UTx325M ships with the monocular, carrying case, USB charging cable, lens cloth, and user manual. Check the specifications tab for the complete package contents.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIR Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400×300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNETD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 25mK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5° × 7.9°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectral Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 - 14µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePixel Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefresh Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFocus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual Focus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1318m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Zoom\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x, 4x, 8x \/ 1.0 - 8x continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImage Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImage Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePNG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMP4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiFi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMobile App\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Xplorer (Android \u0026amp; iOS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Type-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in 16GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.39in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1024×768\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLanguages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnglish, French, German, Spanish, Italian, Russian\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3200 mAh detachable Li-ion battery (UT-M20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 4h (with Wi-Fi off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e357 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 × 71.5 × 38.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Thermal%20Camera%20Datasheets\/UTx313M%26318M%26325M%20Data%20Sheet.pdf\"\u003eUTx325M Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Thermal%20Camera%20User%20Manuals\/UTx313M_UTx318M_UTx325M_User_Manual.pdf\"\u003eUTx325M User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019645226,"sku":"180700300016X","price":2099.0,"currency_code":"USD","in_stock":true}]},{"product_id":"ut622a-lcr-meter","title":"UT622A LCR Meter","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UT622A is a professional-grade handheld LCR meter for component measurement in the field, on the bench, and in the classroom. It measures inductance, capacitance, resistance, impedance, ESR, and D\/Q at test frequencies of 100 Hz, 120 Hz, 1 kHz, and 10 kHz with 0.1% basic accuracy, using a 4-wire Kelvin connection for clean low-impedance readings.\u003c\/p\u003e\n\u003cp\u003eSelectable test signal levels, series\/parallel equivalent-circuit modelling, open\/short correction, and tolerance sorting make it a capable verification tool, and a rechargeable Li-polymer pack gives about 8 hours of portable use on a 2.8-inch color display.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures L, C, R, Z, ESR, and D\/Q with 0.1% basic accuracy\u003c\/li\u003e\n\u003cli\u003eTest frequencies: 100 Hz, 120 Hz, 1 kHz, 10 kHz\u003c\/li\u003e\n\u003cli\u003e4-wire Kelvin connection with open\/short correction\u003c\/li\u003e\n\u003cli\u003eSeries and parallel equivalent-circuit modelling\u003c\/li\u003e\n\u003cli\u003eSelectable test signal: 0.1 \/ 0.3 \/ 1 Vrms\u003c\/li\u003e\n\u003cli\u003eTolerance sorting from 1% to 20%; up to 20 readings\/s\u003c\/li\u003e\n\u003cli\u003e500-group data logging over USB\u003c\/li\u003e\n\u003cli\u003e2.8-inch TFT display; ~8 h rechargeable Li-polymer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUT622A Details\u003c\/h2\u003e\n\u003ch3\u003e4-Wire Kelvin Measurement\u003c\/h3\u003e\n\u003cp\u003eA 4-wire Kelvin connection separates the drive and sense paths so lead and contact resistance don't corrupt the reading — essential for low-impedance components where milliohm-level errors matter. Open and short correction nulls fixture and lead effects before a measurement run.\u003c\/p\u003e\n\u003ch3\u003eFull Parameter Set\u003c\/h3\u003e\n\u003cp\u003eBeyond L, C, and R, the meter reads impedance (Z), equivalent series resistance (ESR), dissipation factor (D), and quality factor (Q), with series or parallel equivalent-circuit modelling and impedance phase from −179.9° to 179.9° — the parameters needed to characterize a part, not just read its nominal value.\u003c\/p\u003e\n\u003ch3\u003eSorting \u0026amp; Logging\u003c\/h3\u003e\n\u003cp\u003eA tolerance-comparison function sorts parts pass\/fail from 1% to 20% bands at up to 20 measurements per second, suited to incoming inspection and small-batch QC. Results log to 500 groups and transfer over USB.\u003c\/p\u003e\n\u003ch3\u003ePortable Build\u003c\/h3\u003e\n\u003cp\u003eA 2.8-inch 320×240 TFT display, a rechargeable 1800 mAh Li-polymer pack good for about 8 hours, and a 420 g body make the UT622A practical to carry between bench, field, and lab.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompare the UT622 Series\u003c\/h2\u003e\n\u003ctable class=\"product-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003cth\u003eUT622A\u003c\/th\u003e\n\u003cth\u003eUT622C\u003c\/th\u003e\n\u003cth\u003eUT622E\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax test frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC resistance (DCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e—\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e0.01 mΩ – 20 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKelvin test leads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e—\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eComponent verification and incoming inspection; field and bench troubleshooting of capacitors, inductors, and resistors; education and lab use; and small-batch sorting against tolerance bands.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eWhat parameters does the UT622A measure?\u003c\/h3\u003e\n\u003cp\u003eInductance, capacitance, resistance, impedance, ESR, and dissipation\/quality factor (D\/Q), at 0.1% basic accuracy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eWhat test frequencies are available?\u003c\/h3\u003e\n\u003cp\u003e100 Hz, 120 Hz, 1 kHz, and 10 kHz.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eHow does it compare to the UT622C and UT622E?\u003c\/h3\u003e\n\u003cp\u003eThe UT622C adds a 100 kHz test frequency and Kelvin leads; the UT622E adds 100 kHz plus DC resistance (DCR) measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Hz, 120 Hz, 1 kHz, 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 pF to 99.999 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 µH to 99.999 H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0000 Ω to 9.9999 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESR Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0000 Ω to 999.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD\/Q Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD: 0.0000 to 9.9999; Q: 0.0000 to 99999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance Phase Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-179.9° to 179.9°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Signal Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 Vrms, 0.3 Vrms, 1 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1% to 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquivalent Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries, Parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto Ranging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto LCR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Short Correction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Wire Kelvin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastest Test Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 times\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMini-USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320×240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 V 1800 mAh Li-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 × 192 × 44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Meter%20Datasheets\/UT622%20Series%20Data%20Sheet.pdf\"\u003eUT622A Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Meter%20User%20Manuals\/UT622A-C-E_User_Manual.pdf\"\u003eUT622A User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019776298,"sku":"180706280021X","price":185.0,"currency_code":"USD","in_stock":true}]},{"product_id":"mso1254hd-250-mhz-4ch-12-bit-mixed-signal-oscilloscope","title":"MSO1254HD 250 MHz 4Ch 12-Bit Mixed Signal Oscilloscope","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO1254HD is a 250 MHz, 4-channel, 12-bit Mixed Signal Oscilloscope built around UNI-T's native 12-bit ADC architecture (R12™). It samples at 2.5 GSa\/s with 100 Mpts of memory depth per channel and captures waveforms at up to 1,000,000 wfms\/s on a 7-inch capacitive touchscreen powered by Ultra Phosphor 3.0 acquisition technology.\u003c\/p\u003e\n\u003cp\u003eBuilt for switching-supply validation, power-stage characterization, and faster-edge embedded debug, the 12-bit ADC delivers 4,096 vertical levels at the full 250 MHz bandwidth — the resolution that lets you measure mV-scale ripple on a 400 V rail, characterize gate-drive ringing on a GaN\/SiC half-bridge, and read efficiency curves with confidence in the small numbers. Standard protocol decoding covers the full embedded-systems vocabulary (RS-232, UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio) at no additional cost. An optional 16-channel logic analyzer pod adds mixed-signal correlation between control firmware and the analog power stage.\u003c\/p\u003e\n\u003cp\u003eThe 9-in-1 architecture consolidates oscilloscope, logic analyzer (with optional UT-M26 pod), spectrum analyzer, protocol analyzer, digital voltmeter, frequency counter, and power analyzer into one instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e250 MHz Bandwidth, 4 Analog Channels\u003c\/strong\u003e — Four-channel acquisition at 12-bit native resolution for mixed-signal debugging, switching-power analysis, and precision sensor work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR12™ — Native 12-Bit ADC at Full Bandwidth\u003c\/strong\u003e — 4,096 vertical levels at every supported bandwidth — no ERES averaging, no sample-rate trade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5 GSa\/s Sample Rate, 100 Mpts\/Channel\u003c\/strong\u003e — Captures fast edges with sufficient timing resolution and holds long records without dropping sample rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1,000,000 wfms\/s Capture Rate\u003c\/strong\u003e — Ultra Phosphor 3.0 intensity-graded display reveals rare anomalies and timing violations that slower scopes miss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Optional Digital Channels\u003c\/strong\u003e — Add mixed-signal debugging with the UT-M26 logic probe pod for time-correlated analog and digital views.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll Protocol Decoding Standard\u003c\/strong\u003e — RS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio decoding included at no additional cost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e — FFT analysis up to 1 Mpts with peak detection and markers for harmonics, clock spurs, and EMI investigation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Automated Measurements\u003c\/strong\u003e — Time, voltage, frequency, and power-quality parameters with statistical analysis and trend graphs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e — 12 power-quality parameters including efficiency, ripple, and switching loss for switching-supply characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7-Inch Capacitive Touchscreen\u003c\/strong\u003e — 1024×600 multi-gesture display with pinch-to-zoom, drag, and gesture navigation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLab-Friendly Connectivity\u003c\/strong\u003e — USB Host\/Device, LAN, AUX Out, HDMI.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eR12™ — Native 12-Bit ADC at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T's native 12-bit ADC architecture. It samples at 4,096 quantization levels — sixteen times the vertical detail of a conventional 8-bit oscilloscope — and holds that resolution at the full 250 MHz bandwidth and 2.5 GSa\/s sample rate. There's no ERES averaging step, no sample-rate trade, and no asterisk on the spec sheet.\u003c\/p\u003e\n\u003cp\u003eFor power-electronics validation at full bandwidth, R12 is what lets the MSO1254HD characterize a GaN\/SiC half-bridge in the same bench session as the gate-drive ringing analysis. On a switching-node measurement where 8-bit quantization noise would obscure the µV-scale ripple riding on a 400 V rail, the 12-bit resolution recovers the signal that drives design decisions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_12-bit-screen.png\" alt=\"R12 12-bit ADC architecture at full bandwidth\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eNative 12-bit ADC delivers 4,096 vertical levels at full bandwidth\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_12-bit-screen.png\" alt=\"R12 12-bit ADC architecture at full bandwidth\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNative 12-bit ADC delivers 4,096 vertical levels at full bandwidth\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 1,000,000 wfms\/s Acquisition\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 drives the acquisition system at up to 1,000,000 waveforms per second with 256 levels of color intensity mapping. The intensity-graded display shows you signal behavior patterns that a slower scope flattens into solid traces — rare glitches, edge jitter, and occasional protocol-layer anomalies appear as faint trace markings against the dominant signal.\u003c\/p\u003e\n\u003cp\u003eFor intermittent-fault investigation, this is the difference between catching the event in a two-minute capture and waiting for it across an overnight run. The probability of capturing rare anomalies scales with capture rate; one million waveforms per second puts you in the territory where most timing violations show up before lunch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Ultra-Phosphor-3.png\" alt=\"Ultra Phosphor 3.0 intensity-graded display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUltra Phosphor 3.0 reveals rare events with intensity grading\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Ultra-Phosphor-3.png\" alt=\"Ultra Phosphor 3.0 intensity-graded display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUltra Phosphor 3.0 reveals rare events with intensity grading\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eDeep Memory — 100 Mpts Per Channel\u003c\/h3\u003e\n\u003cp\u003e100 Mpts of memory depth per channel maintains the full 2.5 GSa\/s sample rate across wide time-base settings — useful for capturing complete switching cycles in power-electronics validation, or recording an entire startup transient at full resolution. Zoom into any portion of the captured record at full resolution.\u003c\/p\u003e\n\u003cp\u003eFor switching-supply analysis, deep memory captures both the fast-edge transitions and the slow-recovery thermal events in a single acquisition. Soft-start sequences, fault-recovery behavior, and burst-mode operation become visible without piecing together multiple captures.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Protocols.png\" alt=\"Comprehensive protocol decoding included as standard\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eComprehensive protocol decoding included standard\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eAll Protocols Included Standard\u003c\/h3\u003e\n\u003cp\u003eUnlike higher-tier families that charge separately for automotive and industrial protocols, the MSO1000HD platform includes RS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio decoding standard at no additional cost. This makes it one of the most complete embedded-debug platforms in its segment, with no surprise license invoices when an automotive project crosses your bench.\u003c\/p\u003e\n\u003cp\u003eEach decoder correlates the physical-layer signal with the decoded data above the trace, so you can see signal-integrity anomalies and protocol errors in the same acquisition. Search and trigger on data patterns, error conditions, or specific bus events to isolate intermittent communication faults.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Protocols.png\" alt=\"Comprehensive protocol decoding included as standard\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eComprehensive protocol decoding included standard\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eBuilt-In Power Analysis — 12 Parameters\u003c\/h3\u003e\n\u003cp\u003e12 standard power-quality parameters cover efficiency analysis, switching-loss measurement, safe-operating-area visualization, ripple-and-noise characterization, and harmonic content. The measurements run inline on the captured waveform — no scripting, no external software, no PC connection required.\u003c\/p\u003e\n\u003cp\u003eCombined with the 12-bit ADC and 100 Mpts memory, the power-analysis suite handles workloads that previously required a dedicated power analyzer. For switching-supply validation, gate-drive characterization, and small-signal-on-DC-rail measurements, the integrated functions consolidate a multi-instrument workflow into one bench unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — FFT to 1 Mpts\u003c\/h3\u003e\n\u003cp\u003eFrequency-domain analysis with peak detection, markers, and waterfall display — up to 1 Mpts FFT length. Identify harmonics, clock spurs, switching-frequency content, and EMI contributions without switching to a separate spectrum analyzer or exporting waveform data to PC software.\u003c\/p\u003e\n\u003cp\u003eThe same trace that captured a glitch in the time domain immediately reveals its spectral character on the FFT — useful for chasing down EMI sources during pre-compliance work, or for distinguishing switching-supply harmonics from coupled noise on adjacent rails.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Spectrum-Analyzer.png\" alt=\"Built-in FFT spectrum analyzer up to 1 Mpts\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBuilt-in FFT spectrum analyzer for harmonics and EMI investigation\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Spectrum-Analyzer.png\" alt=\"Built-in FFT spectrum analyzer up to 1 Mpts\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBuilt-in FFT spectrum analyzer for harmonics and EMI investigation\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eMixed-Signal Debugging — 16 Optional Digital Channels\u003c\/h3\u003e\n\u003cp\u003e16 optional digital channels add mixed-signal debugging via the UT-M26 logic probe pod. The digital traces display alongside analog channels with full time correlation — see I²C bus traffic and analog ADC output on the same time axis, or watch a control firmware state machine drive the gate signals on a switching power stage.\u003c\/p\u003e\n\u003cp\u003eTime-correlated mixed-signal views are essential for debugging the boundary between firmware and analog hardware. A timing-violation that's invisible on either domain alone often becomes obvious when you can see the digital command and the analog response on the same trace.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e56 Automated Measurements with Statistics\u003c\/h3\u003e\n\u003cp\u003e56 automated measurements cover time, voltage, frequency, and power-quality parameters with statistical analysis (min, max, mean, standard deviation) and trend graphs over long captures. For QA work and bench characterization, the statistical view is more useful than the instantaneous reading — it tells you whether a parameter is drifting, jittering, or holding steady.\u003c\/p\u003e\n\u003cp\u003ePass\/fail mask testing applies user-defined tolerance bands across captured waveforms — useful for rapid go\/no-go testing during bring-up, or for validating board-to-board consistency in small-volume production.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eTouch UI and Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe 7-inch 1024×600 capacitive touchscreen supports pinch-to-zoom, drag, and gesture navigation across waveforms, menus, and measurement readouts. For students and lab newcomers, the touch interface lowers the barrier to advanced features that are buried behind menu trees on older instruments.\u003c\/p\u003e\n\u003cp\u003eConnectivity covers USB Host, USB Device, LAN, AUX Out, and HDMI. The HDMI output drives an external display for classroom demonstration, and LAN connectivity integrates the instrument into automated test scripts and remote-access workflows.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D Engineer (Embedded \/ Hardware Design)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching-Supply Validation\u003c\/strong\u003e — Capture switching transitions and measure mV-scale ripple on multi-hundred-volt rails. The 12-bit ADC at full 250 MHz bandwidth resolves the small-signal-on-large-DC measurements that drive design decisions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed-Signal Debug\u003c\/strong\u003e — Time-correlated analog and digital views with the optional UT-M26 logic pod. Track firmware state machines against analog responses on the same trace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Investigation\u003c\/strong\u003e — All standard embedded protocols included; no license fees for automotive (CAN, CAN-FD, LIN), industrial (RS-422\/485), or audio buses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Integrity Spot Checks\u003c\/strong\u003e — FFT analysis identifies harmonics, clock spurs, and EMI sources without switching to a separate spectrum analyzer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Electronics Engineer\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching-Loss Characterization\u003c\/strong\u003e — Built-in power-analysis measurements run inline on the captured waveform — no scripting, no external software. Quantify gate-drive losses, conduction losses, and switching transient energy in one capture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft-Start and Fault-Recovery Capture\u003c\/strong\u003e — 100 Mpts deep memory records the entire transient at sample-rate resolution; no piecing together multi-pass captures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRipple and Noise on DC Rails\u003c\/strong\u003e — The 12-bit ADC resolves µV-scale ripple on multi-hundred-volt DC rails — measurements that an 8-bit scope fundamentally cannot make.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarmonic Content Investigation\u003c\/strong\u003e — Built-in FFT to 1 Mpts identifies switching-frequency content, harmonics, and coupled noise sources.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories \u0026amp; In the Box\u003c\/h2\u003e\n\u003ch3\u003eIncluded with the Instrument\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO1254HD oscilloscope\u003c\/li\u003e\n\u003cli\u003e4 × passive probes (1:1 \/ 10:1 switchable, bandwidth matched to instrument)\u003c\/li\u003e\n\u003cli\u003eUSB cable (USB-A to USB-B)\u003c\/li\u003e\n\u003cli\u003ePower cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eQuick-start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUT-M26 — 16-channel logic probe pod for mixed-signal debugging\u003c\/li\u003e\n\u003cli\u003e\nUT-P07A — 500 MHz passive probe for higher-bandwidth applications\u003c\/li\u003e\n\u003cli\u003e\nUT-P20, UT-P21, UT-V23 — high-voltage passive probes\u003c\/li\u003e\n\u003cli\u003e\nUT-P30, UT-P31, UT-P32, UT-P33 — differential probes for floating measurements\u003c\/li\u003e\n\u003cli\u003e\nUT-P40, UT-P41, UT-P42, UT-P43, UT-P44 — current probes for power-stage and switching-loss measurement\u003c\/li\u003e\n\u003cli\u003e\nUT-ISOT — isolation transformer for safe line-powered measurements\u003c\/li\u003e\n\u003cli\u003e\nUT-M13X — oscilloscope demo board for protocol decoding practice and curriculum modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed an integrated signal generator and Bode plot analysis? See the MSO1254HD-S. Need a 150 MHz value-tier option? See the MSO1154HD.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat protocols are included with the MSO1254HD?\u003c\/p\u003e\n\u003cp\u003eRS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio decoding are included standard at no additional cost. All supported protocols are available out of the box — no optional licenses required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the advantage of native 12-bit resolution?\u003c\/p\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical levels compared to 256 for an 8-bit scope — sixteen times greater detail. This reveals small signals riding on large ones, reduces quantization noise, and improves measurement accuracy on low-amplitude signals like power-supply ripple, sensor outputs, and precision analog circuits. R12™ holds the 12-bit resolution at the full bandwidth and sample rate, with no ERES averaging or sample-rate trade-off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I add digital channels for mixed-signal debugging?\u003c\/p\u003e\n\u003cp\u003eYes. The UT-M26 logic probe pod adds 16 digital channels for time-correlated analog and digital views.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes this model include a signal generator?\u003c\/p\u003e\n\u003cp\u003eNo. For an integrated 1-channel 25 MHz AWG with Bode plot analysis, see the MSO1254HD-S.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow does the MSO1254HD compare to the higher-bandwidth UPO2000HD or MSO3000HD scopes?\u003c\/p\u003e\n\u003cp\u003eThe MSO1000HD platform shares the same R12™ 12-bit ADC architecture, Ultra Phosphor 3.0 acquisition, and standard-included protocol decoding as the UPO2000HD and MSO3000HD families. The differences are bandwidth (150–250 MHz here vs 100–500 MHz on UPO2000HD and 350–1000 MHz on MSO3000HD), capture rate (1,000,000 wfms\/s here vs 1,500,000 wfms\/s on MSO3000HD), and the front-panel form factor. For embedded prototyping and mid-tier power-electronics work, the MSO1000HD platform delivers the same architectural advantages at a lower price point.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the firmware field-upgradable?\u003c\/p\u003e\n\u003cp\u003eYes. Firmware updates are free over the product's lifetime and install via USB drive or LAN transfer.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003ePart of the MSO1000HD oscilloscope series. See the series page to compare bandwidth and channel options across the lineup.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Analog + 16 Optional Digital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Mpts per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000 wfms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-inch capacitive touchscreen, 1024×600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, video, runt, slope, zone, setup\/hold, and more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, Audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In FFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — up to 1 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 with statistics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo (available on -S models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBode Plot Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo (available on -S models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional 16-channel via UT-M26 pod\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host \/ USB Device \/ LAN \/ AUX Out \/ HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=111\"\u003eMSO1254HD Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019809066,"sku":"181100300120X","price":809.0,"currency_code":"USD","in_stock":true}]},{"product_id":"utx313mr-wide-angle-thermal-monocular-with-laser-range","title":"UTx313MR Wide-Angle Thermal Monocular with Laser Range","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003ch3 data-pm-slice=\"1 3 []\"\u003e\u003cspan\u003e\u003cstrong\u003eUNI-T UTx313MR\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan\u003eCompact and Rugged for Mission-Ready Use\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe UNI-T UTx313MR is a versatile thermal monocular that combines portability with rugged durability. It’s designed to perform in tough conditions, making it an excellent choice for search and rescue and security applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBuilt to withstand extreme environments, the UNI-T UTx313MR features a 13mm lens optimized for short-to-mid-range detection. Its advanced thermal sensitivity of ≤35mK ensures accurate and reliable imaging. The rugged construction meets IP67 standards for waterproofing and drop resistance, ensuring the monocular works when you need it most.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe UNI-T UTx313MR stands out with \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003elaser range finding\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e, offering precise distance measurements at the push of a button. Unlike stadiametric ranging, laser range finding provides pinpoint accuracy, which is crucial for time-sensitive applications like search and rescue. This advanced feature enables professionals to make faster, more informed decisions in dynamic situations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIR Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: 400×300 pixels for sharp and detailed imaging\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLens Focal Length\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: 13mm for versatile detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eThermal Sensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: ≤25mK for precise thermal imagery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eField of View (FOV)\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: 20° × 15° for wide-area scanning\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRange Finding\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: Laser\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: 6+ hours of operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurability\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: IP67 waterproof and drop-resistant up to 2 meters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAdditional Features\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e: Hot Trace, Wi-Fi Live Streaming\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the detection range of the UTx313MR?\u003c\/p\u003e\n\u003cp\u003eDetection range depends on the target size and thermal contrast. The UTx313MR's specifications list the maximum detection range for a standard 1.7m × 0.5m target. Actual usable range for identification is typically 30-50% of the maximum detection distance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the UTx313MR waterproof?\u003c\/p\u003e\n\u003cp\u003eThe UTx313MR carries an IP rating for dust and water resistance. Check the specifications tab for the exact IP rating. The device is designed for outdoor use in varying weather conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's included with the UTx313MR?\u003c\/p\u003e\n\u003cp\u003eThe UTx313MR ships with the monocular, carrying case, USB charging cable, lens cloth, and user manual. Check the specifications tab for the complete package contents.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIR Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400×300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNETD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 25mK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20° × 15°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectral Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 - 14µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePixel Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefresh Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFocus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual Focus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e711m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Zoom\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x, 4x, 8x \/ 1.0 - 8x continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImage Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImage Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePNG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMP4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLaser LRF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiFi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMobile App\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Xplorer (Android \u0026amp; iOS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Type-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in 16GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.39in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1024×768\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLanguages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnglish, French, German, Spanish, Italian, Russian\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3250 mAh detachable Li-ion battery (UT-M21)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 4h (with Wi-Fi off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e357 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 × 71.5 × 38.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Thermal%20Camera%20Datasheets\/UTx313MR%26318MR%26325MR%26335MR%20Data%20Sheet.pdf\"\u003eUTx313MR Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Thermal%20Camera%20User%20Manuals\/UTx313MR_UTx318MR_UTx325MR_User_Manual.pdf\"\u003eUTx313MR User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019841834,"sku":"180700300064X","price":1799.0,"currency_code":"USD","in_stock":true}]},{"product_id":"upo2202hd-200-mhz-2ch-12-bit-high-resolution-oscilloscope","title":"UPO2202HD 200 MHz 2Ch 12-Bit High-Resolution Oscilloscope","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UNI-T UPO2202HD is a 200 MHz 2-channel 12-bit high-resolution oscilloscope built around the R12™ native 12-bit ADC. It samples at 2.5 GSa\/s with 100 Mpts memory depth standard, and Ultra Phosphor 3.0 acquisition pushes the waveform capture rate to 1,000,000 wfms\/s in sequence mode — sixteen times the vertical detail of an 8-bit scope, held at full bandwidth without ERES averaging or sample-rate trade-offs. The 10.1-inch capacitive multi-touch display, on-instrument 4 Mpts FFT, 9 standard protocol decoders, and built-in WebServer round out a six-instrument bench in a single chassis.\u003c\/p\u003e\n\u003cp\u003eFor power-electronics validation at the top of this family's bandwidth, the UPO2202HD pairs 200 MHz analog bandwidth with 70 µVrms background noise so that 12-bit resolution actually shows up on the screen instead of being buried in the noise floor. On a GaN\/SiC half-bridge measurement where switching-node ringing and DC-bias content compete for vertical headroom, the resolution gain is the difference between a debug session and an afternoon.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eR12™ 12-bit native ADC\u003c\/strong\u003e — 4,096 vertical levels held at the full 200 MHz bandwidth. No ERES averaging, no sample-rate trade-off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 MHz bandwidth, 2 analog channels\u003c\/strong\u003e — 2.5 GSa\/s real-time sample rate, 100 Mpts standard memory depth. Full-bandwidth 12-bit resolution with 70 µVrms noise floor for power-electronics work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra Phosphor 3.0 — 1,000,000 wfms\/s\u003c\/strong\u003e — Sequence-mode capture rate with 256-level grayscale persistence; surfaces intermittent and rare events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6 instruments in one\u003c\/strong\u003e — Oscilloscope, spectrum analyzer, digital voltmeter, hardware frequency meter, protocol analyzer, and optional power analysis on a single chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9 protocol decoders standard\u003c\/strong\u003e — RS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio. No license fees, no time-boxed unlocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-inch capacitive touchscreen\u003c\/strong\u003e — 1280×800 multi-touch with pinch, drag, zoom, and rectangle-draw gestures. Mouse and keyboard supported in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 Mpts enhanced FFT, 56 automated measurements, hardware mask test, zone trigger, ERES up to 4-bit\u003c\/strong\u003e — standard.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eR12™ — Native 12-Bit ADC at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T's native 12-bit ADC architecture, holding 4,096 quantization levels at the full 200 MHz bandwidth and 2.5 GSa\/s sample rate without ERES averaging or sample-rate trade-off. Background noise is 70 µVrms at full bandwidth — low enough that the 12-bit resolution actually shows up on the screen instead of being buried in the noise floor. For power-electronics validation where µV-scale ripple rides on a 400V bias rail, that headroom is the measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206878\/UPO2000HD_12bit.png\" alt=\"12-bit resolution\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e4,096-level quantization holds at full bandwidth\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206878\/UPO2000HD_12bit.png\" alt=\"12-bit resolution\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e4,096-level quantization holds at full bandwidth\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 1,000,000 wfms\/s Acquisition\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T's third-generation acquisition engine. Eight-channel parallel graphics processing at up to 20 Gbps drives a continuous capture rate of 250,000 wfms\/s, with sequence mode pushing the rate to 1,000,000 wfms\/s for trigger-conditioned events. 256-level grayscale persistence makes intermittent runts, glitches, and jitter visible as density gradients on screen rather than as occasional flashes that the eye misses. The same engine drives the digital trigger system — high sensitivity, low jitter, and zone trigger for isolating non-repeating signals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753215911\/UPO2000HD_Ultra-Phosphor-3.gif\" alt=\"Ultra Phosphor 3.0 acquisition\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eHigh-speed rendering surfaces fast or infrequent anomalies\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753215911\/UPO2000HD_Ultra-Phosphor-3.gif\" alt=\"Ultra Phosphor 3.0 acquisition\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eHigh-speed rendering surfaces fast or infrequent anomalies\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e6 Instruments in One\u003c\/h3\u003e\n\u003cp\u003eThe UPO2202HD integrates six instrument functions into a single chassis: high-resolution oscilloscope, FFT spectrum analyzer with 4 Mpts and waterfall display, 4-digit digital voltmeter with DC\/AC RMS modes, 7-digit hardware frequency meter, 9-protocol decoder and trigger engine, and the optional 12-parameter power analysis suite. For 2-channel benchwork where rack space and budget both matter, the consolidation eliminates instrument switching and context loss during a single debug session.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206877\/UPO2000HD_6-in-1.png\" alt=\"Six instruments in one chassis\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eSix instrument functions on a single bench chassis\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206877\/UPO2000HD_6-in-1.png\" alt=\"Six instruments in one chassis\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eSix instrument functions on a single bench chassis\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eDeep Memory — 100 Mpts Standard\u003c\/h3\u003e\n\u003cp\u003e100 Mpts of memory comes standard, not as an upgrade. At 2.5 GSa\/s that captures 40 ms of full-rate signal in a single acquisition — long enough to record a complete soft-start sequence, a fault-recovery transient, or a multi-frame burst without re-arming. Combined with hardware-accelerated mask testing, the 4-bit ERES enhanced-resolution mode, and uninterrupted recording of up to 125,000 frames, the deep memory turns long-running events from a sampling problem into a navigation problem.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206877\/UPO2000HD_Memory_Depth.png\" alt=\"Deep memory navigation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eZoom across long sequences without losing detail\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206877\/UPO2000HD_Memory_Depth.png\" alt=\"Deep memory navigation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eZoom across long sequences without losing detail\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eAll Protocols Included Standard\u003c\/h3\u003e\n\u003cp\u003eNine serial-bus protocol decoders are included with every UPO2202HD: RS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio. Each protocol supports both triggering and decoding, with event-list and search functions for navigating long captures. Decoded data appears alongside the analog waveform on the same trace — correlate a misbehaving I²C transaction with the supply-rail glitch that caused it, or align CAN-FD frames with the gate-drive event that triggered the fault recovery. No license fees, no time-boxed unlocks — the protocols are standard.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206872\/UPO2000HD_Protocols.png\" alt=\"Standard protocol decoding\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eNine serial-bus protocols decoded alongside the analog trace\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206872\/UPO2000HD_Protocols.png\" alt=\"Standard protocol decoding\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNine serial-bus protocols decoded alongside the analog trace\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003ePower Analysis — Optional 12-Parameter Suite\u003c\/h3\u003e\n\u003cp\u003eThe optional power-analysis package adds 12 measurement and analysis functions to the UPO2202HD: power quality, harmonic analysis, current harmonics, R\u003csub\u003eDS(on)\u003c\/sub\u003e, switching loss, slew rate, safe operating area, modulation analysis, output ripple, startup\/shutdown time, transient response, and power efficiency. Connect a voltage probe and a current probe, select the analysis type, and the UPO2202HD renders the results without external post-processing — the metrics that drive switching-converter design decisions, on the bench, alongside the time-domain trace.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206871\/UPO2000HD_Pwr.png\" alt=\"Power analysis suite\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003ePower quality, switching loss, ripple, and SOA on the same instrument\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206871\/UPO2000HD_Pwr.png\" alt=\"Power analysis suite\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003ePower quality, switching loss, ripple, and SOA on the same instrument\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — FFT to 4 Mpts\u003c\/h3\u003e\n\u003cp\u003eStandard enhanced FFT analysis runs at up to 4 Mpts across all channels with a frequency range from 0 to 1.25 GHz, four traces, four detection modes, and a waterfall display for tracking spectrum changes over time. Auto, manual, and threshold marker modes locate harmonics, spurs, and EMI sources without switching to a separate spectrum analyzer. For pre-compliance spot checks during board bring-up and switching-noise investigation during converter design, the on-instrument FFT closes a common bench-workflow gap.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206871\/UPO2000HD_Spectrum-Analyzer.png\" alt=\"Built-in FFT spectrum analyzer\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eFFT with waterfall and four traces at up to 4 Mpts\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206871\/UPO2000HD_Spectrum-Analyzer.png\" alt=\"Built-in FFT spectrum analyzer\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eFFT with waterfall and four traces at up to 4 Mpts\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e56 Automated Measurements with Statistics\u003c\/h3\u003e\n\u003cp\u003e56 parameter measurements run continuously on every channel, with up to 27 measurements visible on screen and 39 single-channel parameters in the snapshot view. Statistics, histograms, and trend charts visualize each parameter's distribution over time. The new amplitude calculation strategy with top\/bottom and burst-parameter handling makes the numbers correct on signals where naive measurement engines pick the wrong reference levels. No post-processing, no spreadsheet export — the answer is on the screen.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206872\/UPO2000HD_56-measurements.png\" alt=\"56 automated measurements\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eMeasure, visualize, and track parameter distributions on screen\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206872\/UPO2000HD_56-measurements.png\" alt=\"56 automated measurements\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eMeasure, visualize, and track parameter distributions on screen\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e10.1-Inch Touch UI and Full Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe 10.1-inch 1280×800 capacitive multi-touch display supports pinch, drag, zoom, rectangle-draw, and edit gestures alongside the traditional knobs and one-touch front-panel keys. Mouse and keyboard are supported in parallel. The peripheral set includes USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out \/ Pass-Fail), and HDMI for projector or external-monitor display. SCPI is standard, the built-in WebServer enables browser-based remote control from a PC or mobile device, and firmware updates are free over the product's lifetime. For automated power-converter qualification benches, the SCPI command set drives waveform capture, mask-test pass\/fail, and long-record export from a Python or LabVIEW test harness.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206868\/UPO2000HD_Mask.jpg\" alt=\"Touch UI and connectivity\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eMulti-touch gestures with full connectivity and WebServer access\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206868\/UPO2000HD_Mask.jpg\" alt=\"Touch UI and connectivity\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eMulti-touch gestures with full connectivity and WebServer access\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D Engineer (Embedded \/ Hardware \/ Analog Design)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower-Electronics Validation\u003c\/strong\u003e — GaN\/SiC half-bridge characterization, switching-node ringing analysis, and µV-scale ripple-on-bias measurement at 200 MHz bandwidth with 70 µVrms noise floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial-Bus Debug\u003c\/strong\u003e — Time-correlated analog and protocol-decode views in the same trace; 9 protocols included standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal-Integrity Spot Checks\u003c\/strong\u003e — On-instrument 4 Mpts FFT identifies harmonics, clock spurs, and EMI sources without switching to a separate spectrum analyzer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Capture Investigation\u003c\/strong\u003e — 100 Mpts memory plus 125,000-frame waveform recording captures complete soft-start, fault-recovery, and burst-mode events without re-arming.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Electronics Engineer\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFocused Switching-Node Characterization\u003c\/strong\u003e — 200 MHz bandwidth with 70 µVrms noise floor resolves GaN\/SiC switching-edge ringing and µV-scale ripple in the same acquisition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 12-Parameter Power Analysis\u003c\/strong\u003e — Power quality, switching loss, R\u003csub\u003eDS(on)\u003c\/sub\u003e, SOA, transient response, and ripple analysis on the same instrument as the time-domain trace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware-Accelerated Mask Testing\u003c\/strong\u003e — Pass\/fail validation against switching-waveform templates completes in seconds; AUX Out drives an alarm or DUT shutdown on out-of-mask events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Transient Capture\u003c\/strong\u003e — 100 Mpts captures complete soft-start and fault-recovery sequences in one trigger; 125,000-frame waveform recorder for repetitive burst-mode operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories \u0026amp; In the Box\u003c\/h2\u003e\n\u003ch3\u003eIncluded with the Instrument\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO2202HD oscilloscope\u003c\/li\u003e\n\u003cli\u003e2 × passive probes (1:1 \/ 10:1 switchable, bandwidth matched to instrument)\u003c\/li\u003e\n\u003cli\u003eUSB cable (USB-A to USB-B)\u003c\/li\u003e\n\u003cli\u003ePower cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eQuick-start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUPO2000HD-PWR — optional 12-parameter power-analysis package activation\u003c\/li\u003e\n\u003cli\u003e\nUT-P07A — 500 MHz passive probe for higher-bandwidth applications\u003c\/li\u003e\n\u003cli\u003e\nUT-P20, UT-P21, UT-V23 — high-voltage passive probes\u003c\/li\u003e\n\u003cli\u003e\nUT-P30, UT-P31, UT-P32, UT-P33 — differential probes for floating measurements\u003c\/li\u003e\n\u003cli\u003e\nUT-P40, UT-P41, UT-P42, UT-P43, UT-P44 — current probes for power-stage and switching-loss measurement\u003c\/li\u003e\n\u003cli\u003e\nUT-ISOT — isolation transformer for safe line-powered measurements\u003c\/li\u003e\n\u003cli\u003e\nUT-M13X — oscilloscope demo board for protocol decoding practice and curriculum modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed different bandwidth or channel-count? Compare with family-mates: UPO2204HD, UPO2102HD, UPO2072HD.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat protocols are included with the UPO2202HD?\u003c\/p\u003e\n\u003cp\u003eRS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio decoding are included standard at no additional cost. All nine supported protocols are available out of the box — no optional licenses required, no time-boxed unlocks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the advantage of native 12-bit resolution?\u003c\/p\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical levels compared to 256 for an 8-bit scope — sixteen times greater detail. This reveals small signals riding on large ones, reduces quantization noise, and improves measurement accuracy on low-amplitude signals like power-supply ripple, sensor outputs, and precision analog circuits. R12™ holds the 12-bit resolution at the full bandwidth and sample rate, with no ERES averaging or sample-rate trade-off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I add power-supply analysis?\u003c\/p\u003e\n\u003cp\u003eYes. The optional power-analysis package adds 12 measurements: power quality, harmonic analysis, current harmonics, R\u003csub\u003eDS(on)\u003c\/sub\u003e, switching loss, slew rate, safe operating area, modulation analysis, output ripple, startup\/shutdown time, transient response, and power efficiency. The UPO2000HD-PWR activation unlocks the package on any UPO2000HD-series oscilloscope.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow does the touchscreen handle daily lab use?\u003c\/p\u003e\n\u003cp\u003eThe 10.1-inch capacitive multi-touch display supports pinch, drag, zoom, rectangle-draw, and edit gestures alongside the traditional knobs and one-touch front-panel keys. Mouse and keyboard are supported in parallel. For lab settings where students or engineers cycle through the instrument frequently, the gesture set is familiar from consumer devices; for production-style workflows where physical controls are preferred, the front panel still does what front panels do.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow does the UPO2202HD compare to 8-bit oscilloscopes at similar bandwidth?\u003c\/p\u003e\n\u003cp\u003eThe 12-bit ADC delivers 16× the vertical resolution of an 8-bit scope at the same bandwidth, with no ERES averaging or sample-rate trade-off. Low-amplitude signals — switching ripple, sensor outputs, precision analog circuits — that 8-bit scopes flatten into quantization noise show up clearly on the 12-bit display. For analog precision work and switching-converter validation, the resolution advantage is structural, not a marketing comparison.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the firmware field-upgradable?\u003c\/p\u003e\n\u003cp\u003eYes. Firmware updates are free over the product's lifetime and install via USB drive or LAN transfer. Optional license unlocks (such as the power-analysis package) have no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan the instrument be controlled from a PC or from a browser?\u003c\/p\u003e\n\u003cp\u003eBoth. SCPI is supported standard via USB Device or LAN for automated test scripts and PC-side instrument-management software. The built-in WebServer enables direct browser-based control from a PC or mobile device on the same network — no PC-side software install required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003ePart of the UPO2000HD oscilloscope series. All models share the R12™ native 12-bit ADC, 2.5 GSa\/s sample rate, 100 Mpts memory, Ultra Phosphor 3.0 acquisition, and 9 standard protocol decoders. Bandwidth options span 70 \/ 100 \/ 200 MHz; channel options are 2-channel and 4-channel. See the series page to compare configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bits (R12™ native)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000 wfms\/s (sequence mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch capacitive touchscreen, 1280×800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, video, ramp, runt, over-amplitude, delay, timeout, duration, setup\/hold, Nth edge, code pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone Trigger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — 2 zones, must-intersect \/ must-not-intersect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, Audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In FFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — up to 4 Mpts, 0 to 1.25 GHz, 4 traces, waterfall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional — 12 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (standard FFT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Voltmeter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-digit; DC, AC RMS, AC+DC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-digit hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 with statistics, histogram, and trend\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eERES (Enhanced Resolution)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMask Testing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware-accelerated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 125,000 frames; USB export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host \/ USB Device \/ LAN \/ EXT Trig \/ AUX Out \/ HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI standard; built-in WebServer (browser access)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=109\"\u003eUPO2202HD Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUSB3.0 cable\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eSoftware options (model number — description):\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUPO2000HD-PWR — Power Analysis Option for UPO2000HD\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019874602,"sku":"181100200140X","price":924.0,"currency_code":"USD","in_stock":true}]},{"product_id":"mso5000hd-bnd-complete-serial-analysis-bundle","title":"MSO5000HD-BND Complete Serial Analysis Bundle","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO5000HD-BND unlocks the entire library of serial bus analysis options for your MSO5000HD Series oscilloscope in a single license — automotive (CAN-FD, CAN-XL, FlexRay, SENT), embedded (1-Wire, I3C), audio (Audio (I2S\/LJ\/RJ\/TDM)), aerospace (MIL-STD-1553, ARINC 429), wireless\/industrial (Manchester). One key, every protocol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e The bundle costs less than buying the included options separately.\u003c\/strong\u003e Future-proof your bench and eliminate procurement delays. The option is enabled by a software license keyed to the oscilloscope's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's Included\u003c\/strong\u003e — 10 protocols with full trigger, decode, and search:\n\u003cul\u003e\n\u003cli\u003e\nCAN-FD\n\u003c\/li\u003e\n\u003cli\u003e\nCAN-XL\n\u003c\/li\u003e\n\u003cli\u003e\nFlexRay\n\u003c\/li\u003e\n\u003cli\u003e\nSENT (SAE J2716)\n\u003c\/li\u003e\n\u003cli\u003e\n1-Wire\n\u003c\/li\u003e\n\u003cli\u003e\nI3C (MIPI I3C)\n\u003c\/li\u003e\n\u003cli\u003e\nAudio Serial Bus (I2S, LJ, RJ, TDM)\n\u003c\/li\u003e\n\u003cli\u003e\nMIL-STD-1553\n\u003c\/li\u003e\n\u003cli\u003e\nARINC 429\n\u003c\/li\u003e\n\u003cli\u003e\nManchester Encoding\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBundle savings\u003c\/strong\u003e — One bundle price covers every included option for considerably less than buying them separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle License Key\u003c\/strong\u003e — One key unlocks all protocols. No managing separate licenses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuture-Proof\u003c\/strong\u003e — Every protocol ready when you need it. No procurement delays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Domain Development\u003c\/strong\u003e — Your product uses multiple bus types. The BND covers everything from day one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Lab Ready for Anything\u003c\/strong\u003e — Serves clients across automotive, aerospace, and consumer electronics. Every protocol available without scrambling for licenses mid-project.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with all MSO5000HD Series oscilloscopes: MSO5034HD (350 MHz), MSO5054HD (500 MHz), and MSO5104HD (1 GHz). The same capability is offered on other UNI-T oscilloscope families: MSO\/UPO2000, MSO\/UPO3000CS, MSO2000X, MSO3000HD, MSO3000X, MSO7000X, MSO8000HD, UPO7000L.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eI only need two protocols. Is the bundle worth it?\u003c\/h3\u003e\n\u003cp\u003eCompare the combined individual price to the bundle price. The bundle often wins at just two or three protocols — and future projects may need more.\u003c\/p\u003e\n\u003ch3\u003eDoes BND include power analysis, AWG, or bandwidth upgrades?\u003c\/h3\u003e\n\u003cp\u003eNo. BND covers serial bus protocols only. MSO5000HD-AWG Dual Channel 50MHz Arbitrary Waveform Generator with Bode Plot Analysis, MSO5000HD-PWR Advanced Power Analysis, MSO5000HD-TIMING Advanced Timing Analysis are separate options.\u003c\/p\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the oscilloscope's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the instrument from a USB drive through the option-install menu. Refer to the oscilloscope's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019907370,"sku":"191501500004","price":1369.0,"currency_code":"USD","in_stock":true}]},{"product_id":"utx313m-infrared-wide-angle-thermal-monocular","title":"UTx313M Infrared Wide-Angle Thermal Monocular","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003ch3\u003e\u003cstrong\u003eUTx313M\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003eCompact Precision, Big Impact\u003c\/h4\u003e\n\u003cp\u003eDiscover the UTx313M—a lightweight and compact thermal monocular designed for outdoor enthusiasts, search and rescue teams, and security professionals who need a reliable, high-performance thermal imaging solution. Perfect for scanning wide areas and detecting subtle heat signatures in the toughest environments.\u003c\/p\u003e\n\u003cp\u003eThe UTx313M combines cutting-edge thermal imaging technology with a user-friendly design, making it the go-to tool for detecting hidden threats, tracking animals, or locating missing persons. Its 13mm lens and intuitive controls provide unmatched clarity and precision, even in total darkness or adverse weather conditions.\u003c\/p\u003e\n\u003cp\u003eOne of its standout features is stadiametric ranging, a technique that allows users to estimate distances to objects of known size using an adjustable scale. While not as precise as laser range finding, stadiametric ranging offers reliable estimates for quick decision-making in the field. Whether you’re scouting wildlife or performing a rescue mission, this feature enhances situational awareness and efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIR Resolution\u003c\/strong\u003e: 400×300 pixels for crisp thermal imagery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLens Focal Length\u003c\/strong\u003e: 13mm, optimized for short to mid-range detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Sensitivity\u003c\/strong\u003e: ≤25mK for detecting subtle temperature differences\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField of View (FOV)\u003c\/strong\u003e: 20° × 15° for wide-area scanning\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange Finding\u003c\/strong\u003e: Stadiametric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life\u003c\/strong\u003e: 6+ hours of continuous use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurability\u003c\/strong\u003e: IP67 waterproof and drop-proof up to 2 meters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Features\u003c\/strong\u003e: Hot Trace, Wi-Fi Live Streaming\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the detection range of the UTx313M?\u003c\/p\u003e\n\u003cp\u003eDetection range depends on the target size and thermal contrast. The UTx313M's specifications list the maximum detection range for a standard 1.7m × 0.5m target. Actual usable range for identification is typically 30-50% of the maximum detection distance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the UTx313M waterproof?\u003c\/p\u003e\n\u003cp\u003eThe UTx313M carries an IP rating for dust and water resistance. Check the specifications tab for the exact IP rating. The device is designed for outdoor use in varying weather conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's included with the UTx313M?\u003c\/p\u003e\n\u003cp\u003eThe UTx313M ships with the monocular, carrying case, USB charging cable, lens cloth, and user manual. Check the specifications tab for the complete package contents.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIR Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400×300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNETD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 25mK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20° × 15°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectral Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 - 14µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePixel Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefresh Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFocus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual Focus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e687m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Zoom\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x, 4x, 8x \/ 1.0 - 8x continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImage Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImage Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePNG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVideo Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMP4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiFi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMobile App\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Xplorer (Android \u0026amp; iOS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Type-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in 16GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.39in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1024×768\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLanguages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnglish, French, German, Spanish, Italian, Russian\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3200 mAh detachable Li-ion battery (UT-M20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 4h (with Wi-Fi off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e357 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 × 71.5 × 38.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Thermal%20Camera%20Datasheets\/UTx313M%26318M%26325M%20Data%20Sheet.pdf\"\u003eUTx313M Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Thermal%20Camera%20User%20Manuals\/UTx313M_UTx318M_UTx325M_User_Manual.pdf\"\u003eUTx313M User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019940138,"sku":"180700300017X","price":1399.0,"currency_code":"USD","in_stock":true}]},{"product_id":"ut622c-100-khz-lcr-meter","title":"UT622C 100 kHz LCR Meter","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UT622C is a professional-grade handheld LCR meter that extends component testing to 100 kHz. Across 100 Hz, 120 Hz, 1 kHz, 10 kHz, and 100 kHz it measures L, C, R, impedance, ESR, and D\/Q at 0.1% basic accuracy, with a 4-wire Kelvin connection and included Kelvin test leads for repeatable low-impedance readings.\u003c\/p\u003e\n\u003cp\u003eThe higher 100 kHz frequency characterizes parts closer to their working conditions — useful for production QC and design verification — with series\/parallel modelling, open\/short correction, and tolerance sorting on a portable Li-polymer-powered instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest frequencies to 100 kHz: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz\u003c\/li\u003e\n\u003cli\u003eMeasures L, C, R, Z, ESR, and D\/Q with 0.1% basic accuracy\u003c\/li\u003e\n\u003cli\u003e4-wire Kelvin connection with included Kelvin test leads\u003c\/li\u003e\n\u003cli\u003eOpen\/short correction; series and parallel modelling\u003c\/li\u003e\n\u003cli\u003eSelectable test signal: 0.1 \/ 0.3 \/ 1 Vrms\u003c\/li\u003e\n\u003cli\u003eTolerance sorting from 1% to 20%; up to 20 readings\/s\u003c\/li\u003e\n\u003cli\u003e500-group data logging over USB\u003c\/li\u003e\n\u003cli\u003e2.8-inch TFT display; ~8 h rechargeable Li-polymer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUT622C Details\u003c\/h2\u003e\n\u003ch3\u003eTesting to 100 kHz\u003c\/h3\u003e\n\u003cp\u003eExtending the top test frequency to 100 kHz lets you characterize capacitors and inductors closer to the frequencies they operate at, where parameters like ESR and impedance differ meaningfully from their low-frequency values — important for production QC and design verification.\u003c\/p\u003e\n\u003ch3\u003e4-Wire Kelvin Measurement\u003c\/h3\u003e\n\u003cp\u003eA 4-wire Kelvin connection separates the drive and sense paths so lead and contact resistance don't corrupt the reading — essential for low-impedance components where milliohm-level errors matter. Open and short correction nulls fixture and lead effects before a measurement run.\u003c\/p\u003e\n\u003ch3\u003eFull Parameter Set\u003c\/h3\u003e\n\u003cp\u003eBeyond L, C, and R, the meter reads impedance (Z), equivalent series resistance (ESR), dissipation factor (D), and quality factor (Q), with series or parallel equivalent-circuit modelling and impedance phase from −179.9° to 179.9° — the parameters needed to characterize a part, not just read its nominal value.\u003c\/p\u003e\n\u003ch3\u003eSorting \u0026amp; Logging\u003c\/h3\u003e\n\u003cp\u003eA tolerance-comparison function sorts parts pass\/fail from 1% to 20% bands at up to 20 measurements per second, suited to incoming inspection and small-batch QC. Results log to 500 groups and transfer over USB.\u003c\/p\u003e\n\u003ch3\u003ePortable Build\u003c\/h3\u003e\n\u003cp\u003eA 2.8-inch color display, included Kelvin test leads, and a rechargeable Li-polymer pack good for about 8 hours make the UT622C ready for bench and line use.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompare the UT622 Series\u003c\/h2\u003e\n\u003ctable class=\"product-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003cth\u003eUT622A\u003c\/th\u003e\n\u003cth\u003eUT622C\u003c\/th\u003e\n\u003cth\u003eUT622E\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax test frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kHz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC resistance (DCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e—\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mΩ – 20 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKelvin test leads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eProduction QC and incoming inspection; design verification of capacitors and inductors at higher frequency; component characterization on the bench; and tolerance sorting in small-batch manufacturing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eWhat does the 100 kHz frequency add?\u003c\/h3\u003e\n\u003cp\u003eIt characterizes components closer to their operating frequency, where ESR and impedance can differ from low-frequency values.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eDoes it include Kelvin leads?\u003c\/h3\u003e\n\u003cp\u003eYes — Kelvin test leads are included for repeatable 4-wire low-impedance measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eHow is it different from the UT622E?\u003c\/h3\u003e\n\u003cp\u003eThe UT622E adds DC resistance (DCR) measurement from 0.01 mΩ to 20 MΩ on top of the same 100 kHz LCR capability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 pF to 99.999 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 µH to 99.999 H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0000 Ω to 9.9999 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESR Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0000 Ω to 999.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD\/Q Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD: 0.0000 to 9.9999; Q: 0.0000 to 99999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance Phase Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-179.9° to 179.9°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Signal Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 Vrms, 0.3 Vrms, 1 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1% to 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquivalent Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries, Parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto Ranging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto LCR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Short Correction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Wire Kelvin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastest Test Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 times\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMini-USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320×240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 V 1800 mAh Li-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 × 192 × 44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Meter%20Datasheets\/UT622%20Series%20Data%20Sheet.pdf\"\u003eUT622C Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Meter%20User%20Manuals\/UT622A-C-E_User_Manual.pdf\"\u003eUT622C User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275019972906,"sku":"180706280022X","price":253.0,"currency_code":"USD","in_stock":true}]},{"product_id":"utp3305-ii-3ch-335w-32v-5a-linear-dc-power-supply","title":"UTP3305-II 3Ch 335W 32V\/5A Linear DC Power Supply","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UTP3305-II is the precision-grade refresh of UNI-T's UTP3305 platform — the same 335W three-channel linear topology, with a four-digit LED display reading 10 mV \/ 1 mA, tighter regulation specs, and a temperature-controlled cooling fan. Two adjustable channels deliver 0–32V at 0–5A; a third channel provides a fixed 5V at 3A for logic-level power. Knobs, banana jacks, OVP\/OCP via current-limit protection, and a front panel that doesn't require a manual to operate.\u003c\/p\u003e\n\u003cp\u003eLinear regulation keeps output ripple under 1mVrms with no switching artifacts, no EMI signature competing with the circuit you're actually trying to characterize. CH1 and CH2 combine in series (up to 64V) or parallel (up to 10A). Load regulation tightens to CV \u0026lt;0.01% + 3 mV — visible improvement when the load steps and the rail has to hold steady.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Channels, 335W Total\u003c\/strong\u003e — CH1 and CH2: 0–32V \/ 0–5A adjustable. CH3: fixed 5V \/ 3A for logic-level power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour-Digit LED Display, 10 mV \/ 1 mA Resolution\u003c\/strong\u003e — Per-channel voltage and current readouts that read down to 10 mV and 1 mA — fine enough to actually see what the load is doing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTighter Regulation\u003c\/strong\u003e — Load regulation CV \u0026lt;0.01% + 3 mV \/ CC \u0026lt;0.2% + 3 mA. Tracking accuracy ±(0.1% of reading + 30 mV).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Topology, ≤1 mVrms Ripple\u003c\/strong\u003e — Clean DC output with no switching frequency, no harmonic spurs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto CV\/CC Crossover\u003c\/strong\u003e — Automatic transition between constant-voltage and constant-current operation when the load steps, with current limit protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries and Parallel Modes\u003c\/strong\u003e — Combine CH1+CH2 for up to 64V series or 10A parallel — front-panel selectable, no external wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature-Controlled Cooling Fan\u003c\/strong\u003e — Fan speed scales with internal temperature. Quiet at light loads, full airflow when the supply is working hard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput ON\/OFF Control\u003c\/strong\u003e — Front-panel master output button keeps you in command of when current actually leaves the supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKnob-and-Button Operation\u003c\/strong\u003e — No firmware to update, no PC software to install, no LAN port to configure. Front-panel only — designed to behave the same way on day one and year five.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eThe Precision Upgrade That Costs Almost Nothing\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UTP3305-II keeps the operational simplicity of the UTP3305 — knobs, banana jacks, output ON\/OFF — and tightens the parts that matter when your circuit actually responds to the supply. Resolution improves from 100 mV to 10 mV; current resolution drops from 10 mA to 1 mA. Load regulation moves from CV ≤1×10⁻⁴ + 3 mV to CV \u0026lt;0.01% + 3 mV (functionally identical) but with the added programming-accuracy spec ±(0.1% of reading + 30 mV) that the original UTP3305 doesn't publish.\u003c\/p\u003e\n\u003cp\u003eThe temperature-controlled cooling fan is a quality-of-life upgrade that matters in classrooms and small-team R\u0026amp;D rooms: the supply is genuinely quiet at moderate loads, and only spins up when you're actually running it hard. The four-digit LED display replaces the original three-digit dual display — same operational language, finer readout.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cdiv class=\"product-app-grid\"\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eTeaching Labs \u0026amp; Trade Schools\u003c\/h3\u003e\n\u003cp\u003ePer-station cost that lets a 20-bench classroom stay inside budget, with the precision display students actually need to see what's happening on the rail. Quiet fan operation makes a 30-station lab livable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eAnalog Bench Development\u003c\/h3\u003e\n\u003cp\u003e10 mV \/ 1 mA resolution shows the small effects that 100 mV \/ 10 mA hides — supply load lines, sensor bias drift, op-amp quiescent current. Dual 0–32V \/ 5A adjustable channels with tight load regulation power op-amp ±supplies, audio amplifiers, and balanced analog stages.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eService \u0026amp; Repair\u003c\/h3\u003e\n\u003cp\u003eReliable bench supply for board-level service work with the resolution to set rails accurately and the current capability to drive higher-power loads. CV\/CC auto crossover handles unknown loads safely.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eMixed-Signal Prototyping\u003c\/h3\u003e\n\u003cp\u003eTwo adjustable rails with master-slave-style behavior in tracking, plus a fixed 5V CH3 for logic, covers most prototyping needs in a single instrument. Linear output stays clean across the full range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes the UTP3305-II have USB or SCPI?\u003c\/p\u003e\n\u003cp\u003eNo. UNI-T's HQ ordering description literally lists this model as \"Non-Programmable Linear DC Power Supply\" — there is no USB data interface, no LAN, no SCPI command set, no PC software. If your workflow needs SCPI control, the programmable counterparts in the UNI-T linear PSU family are the UDP3303C and UDP3305C (USB + RS-232) and the UDP3000S series (USB + LAN + LXI with web interface).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's the difference between the UTP3305 and UTP3305-II?\u003c\/p\u003e\n\u003cp\u003eThe \"-II\" is the precision-grade refresh of the same 335W \/ 3-channel linear platform: voltage and current resolution improve from 100 mV \/ 10 mA to 10 mV \/ 1 mA, the display moves from 3-digit to 4-digit per channel, and the supply gains a temperature-controlled cooling fan and a published programming-accuracy spec. Output ratings, ripple, and feature set are otherwise comparable. Choose -II for finer readout and quieter operation; choose the original UTP3305 if pricing is the dominant factor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhy a linear supply instead of switching?\u003c\/p\u003e\n\u003cp\u003eLinear topology produces fundamentally cleaner output — no switching frequency, no harmonic spurs, ripple under 1 mVrms. For analog bench work, audio circuits, low-noise sensor development, and any precision measurement where supply noise shows up in the result, the difference is measurable. The trade-off is lower efficiency and more heat, which at this power level on a bench is not a meaningful constraint.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's included with the UTP3305-II?\u003c\/p\u003e\n\u003cp\u003eThe UTP3305-II ships with the instrument, a power cord conforming to the destination country, test output line, English user manual Ships from authorized US dealer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUTP3305-II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 (CH1, CH2 adjustable; CH3 fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH1, CH2: 0–32V\u003cbr\u003eCH3: 5V (fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH1, CH2: 0–5A\u003cbr\u003eCH3: 3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e335W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCV \u0026lt;0.01% + 3 mV\u003cbr\u003eCC \u0026lt;0.2% + 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple \u0026amp; Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage: ≤1 mVrms\u003cbr\u003eCurrent: ≤3 mArms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTracking Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(0.1% of reading + 30 mV)\u003cbr\u003eCC ±(0.3% of reading + 5 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-digit LED, voltage and current per channel (4 windows)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndependent, Series, Parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature-controlled fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent limit protection with auto CV\/CC crossover, output ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReliability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMTBF ≥ 2,000 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V \/ 230V AC, 47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e319 × 146 × 226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=36\"\u003eUTP3305-II Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275020005674,"sku":"181730080312X","price":262.0,"currency_code":"USD","in_stock":false}]},{"product_id":"ut-z004-thermal-monocular-charging-base","title":"UT-Z004 Thermal Monocular Charging Base","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003ePortable charging base for UTx3xxM-series thermal monocular batteries. Charge in the field or at home base to keep your monocular ready for the next deployment. For use with UTx thermal monoculars.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging Base\u003c\/strong\u003e — Convenient desktop charging for UTx thermal monoculars.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with UTx thermal monoculars\u003c\/strong\u003e — See UTx thermal monoculars for details.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275020300586,"sku":"191600600003X","price":80.0,"currency_code":"USD","in_stock":true}]},{"product_id":"ut622e-advanced-lcr-meter","title":"UT622E Advanced LCR Meter","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UT622E is the top of the UT622 line: a professional-grade handheld LCR meter that measures to 100 kHz and adds DC resistance (DCR) from 0.01 mΩ to 20 MΩ — so the same instrument characterizes a component's AC behaviour and its DC resistance, which matters for windings, contacts, and low-value parts. It measures L, C, R, Z, ESR, and D\/Q at 0.1% basic accuracy.\u003c\/p\u003e\n\u003cp\u003eWith a 4-wire Kelvin connection, open\/short correction, series\/parallel modelling, and tolerance sorting, the UT622E suits power-electronics design and lab work, on a portable Li-polymer-powered platform.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAdds DC resistance (DCR) measurement: 0.01 mΩ to 20 MΩ\u003c\/li\u003e\n\u003cli\u003eTest frequencies to 100 kHz: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz\u003c\/li\u003e\n\u003cli\u003eMeasures L, C, R, Z, ESR, and D\/Q with 0.1% basic accuracy\u003c\/li\u003e\n\u003cli\u003e4-wire Kelvin connection with open\/short correction\u003c\/li\u003e\n\u003cli\u003eSeries and parallel equivalent-circuit modelling\u003c\/li\u003e\n\u003cli\u003eTolerance sorting from 1% to 20%; up to 20 readings\/s\u003c\/li\u003e\n\u003cli\u003e500-group data logging over USB\u003c\/li\u003e\n\u003cli\u003e2.8-inch TFT display; ~8 h rechargeable Li-polymer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUT622E Details\u003c\/h2\u003e\n\u003ch3\u003eAC and DC Resistance Together\u003c\/h3\u003e\n\u003cp\u003eBeyond the full AC LCR set, the UT622E measures DC resistance from 0.01 mΩ to 20 MΩ. Reading DCR alongside impedance and ESR characterizes windings, contacts, and low-value components more completely than an AC-only meter — a meaningful step for power-electronics work.\u003c\/p\u003e\n\u003ch3\u003e4-Wire Kelvin Measurement\u003c\/h3\u003e\n\u003cp\u003eA 4-wire Kelvin connection separates the drive and sense paths so lead and contact resistance don't corrupt the reading — essential for low-impedance components where milliohm-level errors matter. Open and short correction nulls fixture and lead effects before a measurement run.\u003c\/p\u003e\n\u003ch3\u003eFull Parameter Set\u003c\/h3\u003e\n\u003cp\u003eBeyond L, C, and R, the meter reads impedance (Z), equivalent series resistance (ESR), dissipation factor (D), and quality factor (Q), with series or parallel equivalent-circuit modelling and impedance phase from −179.9° to 179.9° — the parameters needed to characterize a part, not just read its nominal value.\u003c\/p\u003e\n\u003ch3\u003eSorting \u0026amp; Logging\u003c\/h3\u003e\n\u003cp\u003eA tolerance-comparison function sorts parts pass\/fail from 1% to 20% bands at up to 20 measurements per second, suited to incoming inspection and small-batch QC. Results log to 500 groups and transfer over USB.\u003c\/p\u003e\n\u003ch3\u003ePortable Build\u003c\/h3\u003e\n\u003cp\u003eA 2.8-inch color display and a rechargeable Li-polymer pack good for about 8 hours make the UT622E a capable bench and lab instrument that travels.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompare the UT622 Series\u003c\/h2\u003e\n\u003ctable class=\"product-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003cth\u003eUT622A\u003c\/th\u003e\n\u003cth\u003eUT622C\u003c\/th\u003e\n\u003cth\u003eUT622E\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax test frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kHz\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC resistance (DCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.01 mΩ – 20 MΩ\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKelvin test leads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003ePower-electronics component design and verification; characterization needing both AC parameters and DC resistance; lab and R\u0026amp;D measurement; and production QC with tolerance sorting.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eWhat does the UT622E add over the UT622C?\u003c\/h3\u003e\n\u003cp\u003eDC resistance (DCR) measurement from 0.01 mΩ to 20 MΩ, alongside the same 100 kHz AC LCR capability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eWhy measure DCR as well as ESR?\u003c\/h3\u003e\n\u003cp\u003eDCR characterizes windings, contacts, and low-value parts at DC, complementing the AC parameters for a fuller picture.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eWhat is its basic accuracy?\u003c\/h3\u003e\n\u003cp\u003e0.1% basic accuracy across the LCR measurement set.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 pF to 99.999 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 µH to 99.999 H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0000 Ω to 9.9999 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESR Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0000 Ω to 999.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 MΩ (DCR: 0.01 mΩ to 20.000 MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD\/Q Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD: 0.0000 to 9.9999; Q: 0.0000 to 99999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance Phase Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-179.9° to 179.9°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Signal Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 Vrms, 0.3 Vrms, 1 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1% to 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquivalent Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries, Parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto Ranging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto LCR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Short Correction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Wire Kelvin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastest Test Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 times\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMini-USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320×240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 V 1800 mAh Li-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 × 192 × 44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Meter%20Datasheets\/UT622%20Series%20Data%20Sheet.pdf\"\u003eUT622E Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Meter%20User%20Manuals\/UT622A-C-E_User_Manual.pdf\"\u003eUT622E User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275020333354,"sku":"180706280023X","price":325.0,"currency_code":"USD","in_stock":true}]},{"product_id":"uts-emi01-near-field-probe-kit","title":"UTS-EMI01 Near-Field Probe Kit","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eNear-field probe set for locating EMI sources on PCBs and cables. Compatible with UNI-T spectrum analyzers.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with UNI-T spectrum analyzers\u003c\/strong\u003e — For use with UNI-T spectrum analyzers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Probe Types\u003c\/strong\u003e — Includes H-field and E-field probes for identifying different EMI source types on PCBs and cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClose-Proximity Scanning\u003c\/strong\u003e — Localize interference sources at the component level before running full compliance scans.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 MHz - 3 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 × 180 × 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C - 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMB male (probe), SMA female (adaptor), N male (to analyzer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFP-3G-P1, NFP-3G-P2, NFP-2G-P3, NFP-3G-P4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UTS-EMI01_DataSheet.pdf\"\u003eUTS-EMI01 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275020366122,"sku":"191700100003X","price":450.0,"currency_code":"USD","in_stock":true}]},{"product_id":"uts5026a-26-5-ghz-performance-series-signal-analyzer","title":"UTS5026A 26.5 GHz Performance-Series Signal Analyzer","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"panel\"\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch1\u003eUNI-T UTS5026A 26.5 GHz Performance-Series Signal Analyzer\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTS5026A Performance-Series Signal Analyzer\u003c\/strong\u003e covers \u003cstrong\u003e9 kHz to 26.5 GHz\u003c\/strong\u003e in a single instrument, with \u003cstrong\u003e-163 dBm\/Hz displayed average noise level\u003c\/strong\u003e (typical, with the UTS5000A-P26 preamp option) and \u003cstrong\u003e-107 dBc\/Hz typical phase noise\u003c\/strong\u003e at 1 GHz, 10 kHz offset. Total absolute amplitude accuracy is \u003cstrong\u003e±0.40 dB at 50 MHz\u003c\/strong\u003e reference. RBW resolves from \u003cstrong\u003e1 Hz to 8 MHz\u003c\/strong\u003e and the analyzer captures up to \u003cstrong\u003e100,001 sweep points\u003c\/strong\u003e per trace.\u003c\/p\u003e\n\u003cp\u003eUTS5026A is built around three pillars: \u003cstrong\u003efrequency reach\u003c\/strong\u003e through the K-band ceiling at 26.5 GHz, covering all sub-6 GHz cellular and Wi-Fi bands plus 5G mmWave-adjacent spectrum, SATCOM downlinks, and microwave point-to-point links; a \u003cstrong\u003equiet front end\u003c\/strong\u003e with -163 dBm\/Hz typical DANL (P26 option) and -107 dBc\/Hz typical phase noise that resolves low-level spurs and characterizes oscillator skirts cleanly; and a \u003cstrong\u003emodular measurement library\u003c\/strong\u003e covering vector signal demodulation, I\/Q capture, EMI pre-compliance, 5G NR and LTE air-interface decoding, dedicated phase-noise measurement, and analog AM\/FM demodulation — each available as a no-expiration license unlock. Engineered for RF and microwave design teams, EMC pre-compliance benches, cellular and SATCOM development groups, and private-sector test labs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e9 kHz to 26.5 GHz\u003c\/strong\u003e spectrum measurement — covers sub-6 GHz, K-band, and microwave point-to-point bands in one instrument\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDANL: -163 dBm\/Hz typical\u003c\/strong\u003e (with UTS5000A-P26 preamp option, 20 MHz to 1.5 GHz, 1 Hz RBW); -150 dBm\/Hz typical baseline (preamp off)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase noise: -107 dBc\/Hz typical\u003c\/strong\u003e at 1 GHz, 10 kHz offset\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal absolute amplitude accuracy: ±0.40 dB at 50 MHz\u003c\/strong\u003e reference\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRBW: 1 Hz to 3 MHz in 10% steps\u003c\/strong\u003e, plus 4, 5, 6, 8 MHz wide-band settings; selectivity \u0026lt;4.1 : 1 nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSweep points: up to 100,001\u003c\/strong\u003e per trace; counter resolution 0.001 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrace detectors:\u003c\/strong\u003e Normal, Peak, Sample, Negative Peak, Log Power Average, RMS Average, Voltage Average\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum safe input:\u003c\/strong\u003e +27 dBm average \/ +47 dBm peak (gated)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e15.6-inch 1920×1080 multi-touch HD capacitive display\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional licenses:\u003c\/strong\u003e VSA (digital demod), I\/Q analyzer, EMI pre-compliance, 5G NR \/ LTE FDD \/ LTE TDD demod, AMA (analog AM\/FM), PNM (phase noise), AMK (advanced measurement kit), P26 (preamp gain)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterfaces:\u003c\/strong\u003e RF input (NMD 2.92 mm), 10 MHz Ext Ref In\/Out (BNC), Ext Trigger In (BNC, TTL), HDMI 1.4, USB-A 3.0 + USB-A 2.0 Host, USB-B 2.0 Device, LAN (VXI11)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree firmware updates\u003c\/strong\u003e and \u003cstrong\u003eno-expiration license unlocks\u003c\/strong\u003e\n\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTS5026A Detailed Features\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e9 kHz to 26.5 GHz Frequency Coverage\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UTS5026A spectrum input covers \u003cstrong\u003e9 kHz at the low end and 26.5 GHz at the high end\u003c\/strong\u003e, spanning eleven internal LO frequency bands to maintain calibrated response across the full range. That single-instrument reach removes the need for separate analyzers when work moves between sub-6 GHz cellular spectrum, ISM and Wi-Fi bands, K-band SATCOM downlinks, point-to-point microwave links, and radar IF chains.\u003c\/p\u003e\n\u003cp\u003eFrequency span is selectable from 0 Hz (zero-span time-domain capture) to the full 26.5 GHz range. Sweep time runs \u003cstrong\u003e1 ms to 4,000 s for spans ≥10 Hz\u003c\/strong\u003e, and 1 µs to 6,000 s in zero span for capturing transient events. The 10 MHz internal reference (with ±3×10⁻⁸ temperature stability) ties measurements to a stable timebase, with external 10 MHz reference in\/out on rear-panel BNC for shared-clock instrument racks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1720626350\/UTS5026A_4.jpg\" alt=\"UNI-T UTS5026A 26.5 GHz Performance-Series Signal Analyzer — front three-quarter product view\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUTS5026A front panel with 15.6-inch multi-touch display, RF input (NMD 2.92 mm), and full benchtop instrument footprint.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1720626350\/UTS5026A_4.jpg\" alt=\"UNI-T UTS5026A 26.5 GHz Performance-Series Signal Analyzer — front three-quarter product view\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUTS5026A front panel with 15.6-inch multi-touch display, RF input (NMD 2.92 mm), and full benchtop instrument footprint.\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eSensitivity for Low-Level Signal Detection (DANL -163 dBm\/Hz typ.)\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-Sensitivity.png\" alt=\"UTS5026A DANL sensitivity floor showing -163 dBm\/Hz typical noise level with preamp option\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eDisplayed Average Noise Level reaches -163 dBm\/Hz typical (with UTS5000A-P26 preamp option, 20 MHz to 1.5 GHz, 1 Hz RBW).\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cp\u003eWeak-signal work — identifying low-level spurs in oscillator output, characterizing leakage from a shielded enclosure, capturing intermittent interference — is rate-limited by how far the analyzer’s own noise floor sits below the signal of interest. UTS5026A reaches \u003cstrong\u003e-163 dBm\/Hz typical DANL\u003c\/strong\u003e in the 20 MHz to 1.5 GHz band \u003cem\u003ewith the UTS5000A-P26 preamp option\u003c\/em\u003e, and \u003cstrong\u003e-160 dBm\/Hz typical\u003c\/strong\u003e across most of the analyzer’s mid-band range with preamp engaged. Without P26, baseline DANL runs \u003cstrong\u003e-145 to -150 dBm\/Hz typical\u003c\/strong\u003e mid-band — competitive for general spectrum work, but P26 is what unlocks the headline number.\u003c\/p\u003e\n\u003cp\u003ePreamp coverage extends from \u003cstrong\u003e100 kHz to 7.5 GHz\u003c\/strong\u003e on the low-frequency band and \u003cstrong\u003e100 kHz to 26.5 GHz\u003c\/strong\u003e on the high band. Maximum safe input is \u003cstrong\u003e+27 dBm average\u003c\/strong\u003e (input attenuation ≥20 dB, preamp on) and \u003cstrong\u003e+47 dBm peak\u003c\/strong\u003e for short-pulse work.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-Sensitivity.png\" alt=\"UTS5026A DANL sensitivity floor showing -163 dBm\/Hz typical noise level with preamp option\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eDisplayed Average Noise Level reaches -163 dBm\/Hz typical (with UTS5000A-P26 preamp option, 20 MHz to 1.5 GHz, 1 Hz RBW).\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003ePhase Noise (-107 dBc\/Hz typ.) for Clean Oscillator Characterization\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe local oscillator’s phase noise is the floor that limits how cleanly the analyzer can resolve close-in spurs, modulation sidebands, and reciprocal mixing artifacts on the device under test. UTS5026A specifies \u003cstrong\u003e-107 dBc\/Hz typical at 10 kHz offset\u003c\/strong\u003e from a 1 GHz carrier, with \u003cstrong\u003e-102 dBc\/Hz at 1 kHz\u003c\/strong\u003e, \u003cstrong\u003e-110 dBc\/Hz at 100 kHz\u003c\/strong\u003e, and \u003cstrong\u003e-132 dBc\/Hz at 1 MHz\u003c\/strong\u003e offset (typical, 1 kHz RBW, 10 Hz VBW, log-average over \u0026gt;50 acquisitions).\u003c\/p\u003e\n\u003cp\u003eFor RF designers characterizing PLL synthesizers, VCOs, and crystal oscillators, that envelope means close-in noise sidebands on the device under test sit above the analyzer’s own contribution rather than buried beneath it. The \u003cstrong\u003eUTS5000A-PNM Phase Noise Measurement option\u003c\/strong\u003e adds a dedicated measurement mode with logarithmic offset axes, jitter calculation, and integration limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-Phase_Noise.png\" alt=\"UTS5026A phase noise plot showing -107 dBc\/Hz typical at 1 GHz center frequency, 10 kHz offset\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eNominal phase noise at 1 GHz center frequency: -100 dBc\/Hz at 1 kHz offset, -107 dBc\/Hz at 10 kHz offset, -132 dBc\/Hz at 1 MHz offset (typical).\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-Phase_Noise.png\" alt=\"UTS5026A phase noise plot showing -107 dBc\/Hz typical at 1 GHz center frequency, 10 kHz offset\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNominal phase noise at 1 GHz center frequency: -100 dBc\/Hz at 1 kHz offset, -107 dBc\/Hz at 10 kHz offset, -132 dBc\/Hz at 1 MHz offset (typical).\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eRBW Resolution and Selectivity (1 Hz to 8 MHz)\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727993120\/UTS5000A-RBW.jpg\" alt=\"UTS5026A resolution bandwidth filter showing 1 Hz minimum to 8 MHz maximum settings\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eRBW: 1 Hz to 3 MHz in 10% steps, plus 4, 5, 6, and 8 MHz wide-band settings.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cp\u003eResolution Bandwidth selects from \u003cstrong\u003e1 Hz to 3 MHz in 10% steps\u003c\/strong\u003e (the standard 10:1 ratio family used across professional spectrum analyzers), plus dedicated \u003cstrong\u003e4, 5, 6, and 8 MHz\u003c\/strong\u003e wide-band settings for fast sweeps over wide spans. Bandwidth accuracy is \u003cstrong\u003e±1.0% (±0.044 dB) nominal\u003c\/strong\u003e from 1 Hz to 750 kHz.\u003c\/p\u003e\n\u003cp\u003eSelectivity (the −60 dB to −3 dB shape factor) measures \u003cstrong\u003e\u0026lt;4.1 : 1 nominal\u003c\/strong\u003e, which lets two adjacent unequal-amplitude carriers resolve cleanly without the smaller signal disappearing into the larger one’s skirt. Video bandwidth tracks the same range, and seven trace detectors cover both general-purpose and standards-specific measurement modes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727993120\/UTS5000A-RBW.jpg\" alt=\"UTS5026A resolution bandwidth filter showing 1 Hz minimum to 8 MHz maximum settings\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eRBW: 1 Hz to 3 MHz in 10% steps, plus 4, 5, 6, and 8 MHz wide-band settings.\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e100,001 Sweep Points for Fine-Grained Frequency Analysis\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eSweep point count is configurable from \u003cstrong\u003e11 to 100,001 across all spans\u003c\/strong\u003e. At 100,001 points across a 1 GHz span, frequency resolution per trace bin is \u003cstrong\u003e10 kHz\u003c\/strong\u003e — tight enough to localize narrow-band interference, identify specific ITU channel allocations, and walk between adjacent regulatory mask boundaries without interpolation between coarse sweep bins.\u003c\/p\u003e\n\u003cp\u003eMarker resolution scales with the trace span and sweep-point count. A dedicated frequency counter mode tightens uncertainty further, with counter resolution at \u003cstrong\u003e0.001 Hz\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-ScanPoints.png\" alt=\"UTS5026A trace with 100,001 sweep points showing high-resolution frequency-domain detail\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eTrace acquisition supports up to 100,001 sweep points across any selected span.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-ScanPoints.png\" alt=\"UTS5026A trace with 100,001 sweep points showing high-resolution frequency-domain detail\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eTrace acquisition supports up to 100,001 sweep points across any selected span.\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eVector Signal Analysis and I\/Q Capture (UTS5000A-VSA + UTS5000A-I\/Q Options)\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUTS5000A-VSA Digital Demodulation option\u003c\/strong\u003e adds a vector demodulation engine covering \u003cstrong\u003e2 MHz to 26.5 GHz carrier\u003c\/strong\u003e and the major digital modulation formats: \u003cstrong\u003eASK (2-ASK); FSK (2\/4\/8\/16); MSK (GMSK); PSK (BPSK, QPSK, OQPSK, 8PSK); DPSK (DBPSK, DQPSK, D8PSK, π\/4-DQPSK, π\/8-D8PSK); QAM (16, 32, 64, 128, 256)\u003c\/strong\u003e. Symbol rate ranges \u003cstrong\u003e1 ksps to 2.5 Msps\u003c\/strong\u003e, with EVM\/SNR statistics displayed alongside IQ constellation, eye, and time-domain views.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eUTS5000A-I\/Q Analyzer option\u003c\/strong\u003e adds direct I\/Q capture and spectrum analysis at \u003cstrong\u003e9 kHz to 25 MHz analysis bandwidth standard (extended to 40 MHz with B40)\u003c\/strong\u003e, with a \u003cstrong\u003e14-bit ADC at 90 MSa\/s\u003c\/strong\u003e capturing up to 4,000,000 IQ sample pairs per acquisition. Window selection covers Flat-top, Uniform, Hanning, Gaussian, Blackman, Blackman-Harris, and Kaiser-Bessel shapes. Together, the two options form the foundation for waveform-level characterization of arbitrary digitally-modulated carriers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e5G NR and LTE Air-Interface Demodulation (UTS5000A-NR \/ FDD-LTE \/ TDD-LTE Options)\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eFor teams developing 5G New Radio infrastructure, LTE base-station components, or cellular-band devices, three dedicated demodulation licenses extend the analyzer into protocol-aware air-interface measurement: \u003cstrong\u003eUTS5000A-NR for 5G New Radio\u003c\/strong\u003e, \u003cstrong\u003eUTS5000A-FDD-LTE\u003c\/strong\u003e, and \u003cstrong\u003eUTS5000A-TDD-LTE\u003c\/strong\u003e. Each license is a standalone purchase.\u003c\/p\u003e\n\u003cp\u003eCombined with the analyzer’s 26.5 GHz frequency reach, the cellular licenses cover sub-6 GHz LTE and 5G NR FR1 deployments directly, plus 5G NR FR2 mmWave bands at 24.25–26.5 GHz. The instrument’s low phase noise and tight amplitude accuracy translate into clean EVM measurements on the device under test. License unlocks are no-expiration: once added, they remain on the instrument for the life of the unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eEMI Pre-Compliance to 26.5 GHz (UTS5000A-EMI Option)\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727993123\/UTS5000A-EMI_Screen.jpg\" alt=\"UTS5026A EMI pre-compliance measurement screen with regulatory mask overlay and detector trace\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eEMI pre-compliance measurement mode with regulatory limit lines, quasi-peak detection, and near-field probe support.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUTS5000A-EMI Pre-Compliance Measurement option\u003c\/strong\u003e transforms the analyzer into a CISPR\/EN-class pre-compliance instrument with regulatory limit lines, quasi-peak and average detectors, and band-segmented scan modes. Measurement extends to the analyzer’s full \u003cstrong\u003e26.5 GHz ceiling\u003c\/strong\u003e, covering not just the traditional 30 MHz to 1 GHz radiated-emissions band but also the higher-frequency emissions from 5G transceivers, automotive radar, and microwave data links.\u003c\/p\u003e\n\u003cp\u003eThe companion \u003cstrong\u003eUTS-EMI01 near-field probes kit\u003c\/strong\u003e adds four probe heads spanning 30 MHz to 3 GHz at three resolution scales plus a 5 mm resolution probe to 2 GHz, for localizing radiating components on a populated PCB. Pre-compliance use moves EMI debugging earlier in the development cycle — before the formal test-house chamber visit, when board-level fixes are still cheap.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727993123\/UTS5000A-EMI_Screen.jpg\" alt=\"UTS5026A EMI pre-compliance measurement screen with regulatory mask overlay and detector trace\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eEMI pre-compliance measurement mode with regulatory limit lines, quasi-peak detection, and near-field probe support.\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e15.6″ Multi-Touch HD Display and Serviceable Front End\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1706309659\/UTS5026A_Touch_Screen.png\" alt=\"UTS5026A 15.6-inch multi-touch capacitive display showing trace zoom and multi-window layout\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e15.6-inch multi-touch capacitive HD display with gesture support: drag, pinch-zoom, and trace expansion.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cp\u003eThe front-panel display is a \u003cstrong\u003e15.6-inch 1920×1080 multi-touch capacitive TFT LCD\u003c\/strong\u003e — a deliberate departure from the 7-to-10-inch displays common at this frequency tier. Capacitive multi-touch supports drag-to-pan, pinch-zoom on traces, and gesture-based menu navigation, with the larger display real estate accommodating up to 4-window simultaneous layouts in the VSA and I\/Q modes. The instrument is built for serviceability over the warranty lifetime: a \u003cstrong\u003eremovable dust filter\u003c\/strong\u003e on the air inlet lifts out for cleaning, preventing the dust-accumulation failure mode that limits long-term reliability on cooled bench instruments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1706309659\/UTS5026A_Touch_Screen.png\" alt=\"UTS5026A 15.6-inch multi-touch capacitive display showing trace zoom and multi-window layout\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e15.6-inch multi-touch capacitive HD display with gesture support: drag, pinch-zoom, and trace expansion.\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eRF and Microwave Design \/ R\u0026amp;D\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eFor RF and microwave design teams characterizing PLL synthesizers, mixer spurious products, amplifier compression, and front-end module performance, the UTS5026A’s 26.5 GHz reach with -107 dBc\/Hz typical phase noise gives the instrument the headroom to act as the reference measurement on the bench. The 100,001-point sweep resolution, ±0.40 dB amplitude accuracy at 50 MHz, and full SCPI\/LXI remote control make the analyzer a primary fixture in R\u0026amp;D characterization workflows.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e5G NR and LTE Cellular Development\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eWith the UTS5000A-NR, FDD-LTE, and TDD-LTE demodulation licenses, the analyzer covers sub-6 GHz cellular bands plus 5G NR FR2 mmWave allocations in the 24.25 to 26.5 GHz range. Combined with the I\/Q analyzer’s 40 MHz (B40) analysis bandwidth, the instrument supports waveform-level evaluation of base-station transmitters, small-cell units, and cellular-band devices.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eEMC Pre-Compliance and Production Test Labs\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eProduction characterization labs and EMC pre-compliance benches use the UTS5026A’s combination of 26.5 GHz frequency ceiling, regulatory-grade amplitude accuracy, and the optional UTS5000A-EMI license to run pre-chamber scans across CISPR-band ranges and into 5G transceiver and radar emission bands. Free firmware updates plus no-expiration license unlocks keep the instrument current as standards evolve.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories \u0026amp; In the Box\u003c\/h2\u003e\n\u003ch3\u003eStandard Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord × 1\u003c\/li\u003e\n\u003cli\u003eUSB cable × 1 (UT-D14)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMeasurement option licenses (no-expiration unlock)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-NR\u003c\/strong\u003e — 5G New Radio (NR) demodulation analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-FDD-LTE\u003c\/strong\u003e — LTE FDD demodulation analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-TDD-LTE\u003c\/strong\u003e — LTE TDD demodulation analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-VSA\u003c\/strong\u003e — Digital demodulation (ASK\/FSK\/PSK\/QAM\/MSK\/DPSK) with EVM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-I\/Q\u003c\/strong\u003e — I\/Q analyzer (25 MHz \/ 40 MHz with B40 analysis BW)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-EMI\u003c\/strong\u003e — EMI pre-compliance measurement to 26.5 GHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-AMA\u003c\/strong\u003e — Analog AM\/FM demodulation, 2 MHz to 26.5 GHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-PNM\u003c\/strong\u003e — Phase Noise Measurement (dedicated mode)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-AMK\u003c\/strong\u003e — Advanced Measurement Kit (channel power, ACPR, OBW, T-power, harmonics)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-P26\u003c\/strong\u003e — Preamplifier gain option (unlocks -163 dBm\/Hz typ. DANL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRF cables and connector kits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-CK02 kit\u003c\/strong\u003e — RF cables and connectors: UT-W03-40GHz cable, UT-C04-40GHz adapter, UT-C03-18GHz adapter, UT-W03 SMA-SMB cable, UT-C01 SMA-N adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNear-field probes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS-EMI01 kit\u003c\/strong\u003e — Four near-field probes: NFP-3G-P1 (30 MHz–3 GHz, 10 cm range), NFP-3G-P2 (30 MHz–3 GHz, 3 cm range), NFP-2G-P3 (30 MHz–2 GHz, 5 mm resolution), NFP-3G-P4 (30 MHz–3 GHz, 2 mm resolution)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's the difference between the UTS5000A and the UTS3000A series?\u003c\/p\u003e\n\u003cp\u003eThe two analyzers target different work. The \u003cstrong\u003eUTS3000A series\u003c\/strong\u003e covers 9 kHz to 3.6 \/ 6 \/ 8.4 GHz with a \u003cstrong\u003ebuilt-in tracking generator and standard real-time spectrum analysis plus VNA capability (S11 + S21)\u003c\/strong\u003e; it’s the right choice when work involves stimulus-response measurements, real-time transient capture as a standard capability, and characterization below 8.4 GHz.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eUTS5000A (UTS5026A)\u003c\/strong\u003e is a measurement-only analyzer covering \u003cstrong\u003e9 kHz to 26.5 GHz\u003c\/strong\u003e with no tracking generator and no VNA. It targets work that needs \u003cstrong\u003efrequency reach above 8.4 GHz\u003c\/strong\u003e — K-band SATCOM, 5G NR FR2 mmWave bands, 24 GHz radar, microwave links — or the deeper option library covering 5G NR \/ LTE demodulation and dedicated phase-noise measurement that the UTS3000A doesn’t offer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhich capabilities are standard, and which require optional licenses?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e (included): swept and FFT spectrum analysis from 9 kHz to 26.5 GHz, with all the headline specifications — 1 Hz to 8 MHz RBW, 100,001 sweep points, ±0.40 dB amplitude accuracy at 50 MHz, -107 dBc\/Hz typical phase noise, the full trace-detector set, marker functions, and SCPI\/LAN\/USB remote control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional licenses\u003c\/strong\u003e (each sold separately, no-expiration unlock): UTS5000A-VSA (digital demodulation), UTS5000A-I\/Q (I\/Q analyzer), UTS5000A-EMI (EMI pre-compliance), UTS5000A-NR (5G NR demod), UTS5000A-FDD-LTE and UTS5000A-TDD-LTE (LTE demod), UTS5000A-AMA (analog AM\/FM demod), UTS5000A-PNM (phase-noise measurement), UTS5000A-AMK (advanced measurement kit), and UTS5000A-P26 (preamplifier gain — unlocks the -163 dBm\/Hz typical DANL specification).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes the UTS5026A include a tracking generator or VNA function?\u003c\/p\u003e\n\u003cp\u003eNo. The UTS5026A is a measurement-only signal analyzer — it does not produce stimulus signals. There is no internal tracking generator, no VNA capability, and no S-parameter measurement function. For applications requiring stimulus-response measurements (filter characterization, antenna VSWR, S11 \/ S21), the UTS3000A series provides those capabilities up to 8.4 GHz with a built-in reflection bridge and tracking generator. For frequencies above 8.4 GHz, an external signal generator paired with the UTS5026A in receive-only mode is the typical configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I add the UTS5000A-P26 preamplifier option later, after the original purchase?\u003c\/p\u003e\n\u003cp\u003eYes. All UTS5000A optional licenses, including the P26 preamplifier gain option, are \u003cstrong\u003eno-expiration license unlocks\u003c\/strong\u003e that can be added at any time after the original instrument purchase. The hardware to support each option is present in every shipping unit; the license unlocks the firmware functionality. Adding P26 after purchase requires no service-depot return.\u003c\/p\u003e\n\u003cp\u003eThat makes a typical procurement path practical: buy the base instrument, then add P26, VSA, I\/Q, or cellular demod licenses as the project mix evolves.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the UTS5026A remotely programmable?\u003c\/p\u003e\n\u003cp\u003eYes. The UTS5026A supports a complete \u003cstrong\u003eSCPI command set\u003c\/strong\u003e covering every front-panel function, accessible over \u003cstrong\u003eUSB-B 2.0, LAN (VXI-11 over 10\/100\/1000 Base RJ-45)\u003c\/strong\u003e, and through the built-in WebServer interface for browser-based access. The full programming manual ships with the instrument, and the analyzer integrates into ATE racks running NI-VISA, Keysight IO Libraries, or any standards-compliant instrument-control framework, with LXI conventions for network discoverability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 26.5 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.000000 MHz, ±3×10⁻⁸ stability (20 to 30 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRBW range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 3 MHz (10% steps), 4, 5, 6, 8 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRBW selectivity (-60 dB \/ -3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;4.1 : 1 (-60 dB \/ -3 dB, nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100,001 (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ms to 4,000 s (span ≥ 10 Hz); 1 µs to 6,000 s (zero span)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFree Run, External 1, External 2, Video, Periodic Timer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDANL (preamp on, with UTS5000A-P26)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-163 dBm\/Hz typ. (20 MHz to 1.5 GHz typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDANL (preamp off, baseline)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-150 dBm\/Hz typ. (20 MHz to 1.5 GHz typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase noise (1 GHz, 10 kHz \/ 1 MHz offset)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-107 \/ -132 dBc\/Hz typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal absolute amplitude accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(0.40 dB + frequency response)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplitude accuracy at 50 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.40 dB at 50 MHz reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference level range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-170 dBm to +30 dBm, 0.01 dB steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput attenuator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50 dB, 2 dB steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum safe input (avg \/ peak \/ DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+27 dBm avg \/ +47 dBm peak (gated) \/ +16 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThird-order intercept (TOI, typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+16 dBm typ. (10 MHz to 2 GHz, preamp off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual spurious response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-90 dBm (200 kHz to 26.5 GHz, swept)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrace detectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormal, Peak, Sample, Negative Peak, Log Power Average, RMS Average, Voltage Average\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of traces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.6 inch, 1920 x 1080, Multi-touch capacitive TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRF input connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNMD 2.92 mm male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExt reference in \/ out\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MHz BNC: -5 to +10 dBm in \/ \u0026gt;0 dBm out, 50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB \/ LAN \/ HDMI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-A 3.0 (front) + USB-A 2.0 (rear) Host; USB-B 2.0 Device; LAN (VXI11) 10\/100\/1000; HDMI 1.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC (±10%), 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature \/ humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to +40 °C; ≤90% RH below +35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \/ weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e445 mm × 311 mm × 195 mm (W × H × D) \/ About 11 kg (24.3 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications \/ ECCN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus \/ 3A992.a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=93\"\u003eUTS5026A Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUSB2.0 printing cable\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eSoftware options (model number — description):\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUTS5000A-AMA — AM\/FM Analog Demodulation Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-AMK — Advanced Measurement Kit Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-EMI — EMI Pre-Compliance Measurement Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-FDD-LTE — FDD-LTE Demodulation Analysis Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-I\/Q — I\/Q Analyzer Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-NR — NR demodulation analysis option for UTS5000A series\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-P26 — Preamplifier Gain Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-PNM — Phase Noise Measurement Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-TDD-LTE — TDD-LTE Demodulation Analysis Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-VSA — Digital Demodulation Analysis Option\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275020398890,"sku":"181200100024X","price":31499.0,"currency_code":"USD","in_stock":true}]},{"product_id":"mso1154hd-150-mhz-4ch-12-bit-mixed-signal-oscilloscope","title":"MSO1154HD 150 MHz 4Ch 12-Bit Mixed Signal Oscilloscope","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO1154HD is a 150 MHz, 4-channel, 12-bit Mixed Signal Oscilloscope built around UNI-T's native 12-bit ADC architecture (R12™). It samples at 2.5 GSa\/s with 100 Mpts of memory depth per channel and captures waveforms at up to 1,000,000 wfms\/s on a 7-inch capacitive touchscreen powered by Ultra Phosphor 3.0 acquisition technology.\u003c\/p\u003e\n\u003cp\u003eBuilt for embedded prototyping and curriculum-grade lab work, the 12-bit ADC delivers 4,096 vertical levels at the full 150 MHz bandwidth — the resolution gain that lets you see small ripple riding on a switching rail, or the subtle gain compression at the edge of an amplifier's linear range, without dropping into ERES averaging. Standard protocol decoding covers the full embedded-systems vocabulary (RS-232, UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio) at no additional cost. An optional 16-channel logic analyzer pod adds mixed-signal debugging when the project needs it.\u003c\/p\u003e\n\u003cp\u003eThe 9-in-1 architecture consolidates oscilloscope, logic analyzer (with optional UT-M26 pod), spectrum analyzer, protocol analyzer, digital voltmeter, frequency counter, and power analyzer into one instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e150 MHz Bandwidth, 4 Analog Channels\u003c\/strong\u003e — Four-channel acquisition at 12-bit native resolution for mixed-signal debugging, switching-power analysis, and precision sensor work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR12™ — Native 12-Bit ADC at Full Bandwidth\u003c\/strong\u003e — 4,096 vertical levels at every supported bandwidth — no ERES averaging, no sample-rate trade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5 GSa\/s Sample Rate, 100 Mpts\/Channel\u003c\/strong\u003e — Captures fast edges with sufficient timing resolution and holds long records without dropping sample rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1,000,000 wfms\/s Capture Rate\u003c\/strong\u003e — Ultra Phosphor 3.0 intensity-graded display reveals rare anomalies and timing violations that slower scopes miss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Optional Digital Channels\u003c\/strong\u003e — Add mixed-signal debugging with the UT-M26 logic probe pod for time-correlated analog and digital views.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll Protocol Decoding Standard\u003c\/strong\u003e — RS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio decoding included at no additional cost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e — FFT analysis up to 1 Mpts with peak detection and markers for harmonics, clock spurs, and EMI investigation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Automated Measurements\u003c\/strong\u003e — Time, voltage, frequency, and power-quality parameters with statistical analysis and trend graphs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e — 12 power-quality parameters including efficiency, ripple, and switching loss for switching-supply characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7-Inch Capacitive Touchscreen\u003c\/strong\u003e — 1024×600 multi-gesture display with pinch-to-zoom, drag, and gesture navigation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLab-Friendly Connectivity\u003c\/strong\u003e — USB Host\/Device, LAN, AUX Out, HDMI.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eR12™ — Native 12-Bit ADC at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T's native 12-bit ADC architecture. It samples at 4,096 quantization levels — sixteen times the vertical detail of a conventional 8-bit oscilloscope — and holds that resolution at the full 150 MHz bandwidth and 2.5 GSa\/s sample rate. There's no ERES averaging step, no sample-rate trade, and no asterisk on the spec sheet.\u003c\/p\u003e\n\u003cp\u003eFor embedded prototyping at the value tier, R12 is what makes the MSO1154HD a credible benchtop scope rather than a hobby instrument with 12-bit on the spec sheet. On a workbench where the alternative is an 8-bit scope showing quantization steps over a switching-supply ripple measurement, the resolution gain is the difference between a debug session and an afternoon staring at a noisy trace.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_12-bit-screen.png\" alt=\"R12 12-bit ADC architecture at full bandwidth\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eNative 12-bit ADC delivers 4,096 vertical levels at full bandwidth\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_12-bit-screen.png\" alt=\"R12 12-bit ADC architecture at full bandwidth\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNative 12-bit ADC delivers 4,096 vertical levels at full bandwidth\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 1,000,000 wfms\/s Acquisition\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 drives the acquisition system at up to 1,000,000 waveforms per second with 256 levels of color intensity mapping. The intensity-graded display shows you signal behavior patterns that a slower scope flattens into solid traces — rare glitches, edge jitter, and occasional protocol-layer anomalies appear as faint trace markings against the dominant signal.\u003c\/p\u003e\n\u003cp\u003eFor intermittent-fault investigation, this is the difference between catching the event in a two-minute capture and waiting for it across an overnight run. The probability of capturing rare anomalies scales with capture rate; one million waveforms per second puts you in the territory where most timing violations show up before lunch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Ultra-Phosphor-3.png\" alt=\"Ultra Phosphor 3.0 intensity-graded display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUltra Phosphor 3.0 reveals rare events with intensity grading\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Ultra-Phosphor-3.png\" alt=\"Ultra Phosphor 3.0 intensity-graded display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUltra Phosphor 3.0 reveals rare events with intensity grading\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eDeep Memory — 100 Mpts Per Channel\u003c\/h3\u003e\n\u003cp\u003e100 Mpts of memory depth per channel maintains the full 2.5 GSa\/s sample rate across wide time-base settings — useful when teaching lab modules require capturing an extended sequence (a complete UART transaction, a startup transient, a slow PWM ramp) at sample-rate resolution. Zoom into any portion of the captured record at full resolution.\u003c\/p\u003e\n\u003cp\u003eFor embedded prototyping, deep memory means a single capture catches the slow events between fast edges — the millisecond-scale firmware delay that prevents an interrupt from firing on time, or the sequencing problem on a slow I²C bus. One acquisition replaces a multi-pass debug session.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Protocols.png\" alt=\"Comprehensive protocol decoding included as standard\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eComprehensive protocol decoding included standard\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eAll Protocols Included Standard\u003c\/h3\u003e\n\u003cp\u003eUnlike higher-tier families that charge separately for automotive and industrial protocols, the MSO1000HD platform includes RS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio decoding standard at no additional cost. This makes it one of the most complete embedded-debug platforms in its segment, with no surprise license invoices when an automotive project crosses your bench.\u003c\/p\u003e\n\u003cp\u003eEach decoder correlates the physical-layer signal with the decoded data above the trace, so you can see signal-integrity anomalies and protocol errors in the same acquisition. Search and trigger on data patterns, error conditions, or specific bus events to isolate intermittent communication faults.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Protocols.png\" alt=\"Comprehensive protocol decoding included as standard\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eComprehensive protocol decoding included standard\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eBuilt-In Power Analysis — 12 Parameters\u003c\/h3\u003e\n\u003cp\u003e12 standard power-quality parameters cover efficiency analysis, switching-loss measurement, safe-operating-area visualization, ripple-and-noise characterization, and harmonic content. The measurements run inline on the captured waveform — no scripting, no external software, no PC connection required.\u003c\/p\u003e\n\u003cp\u003eCombined with the 12-bit ADC and 100 Mpts memory, the power-analysis suite handles workloads that previously required a dedicated power analyzer. For switching-supply validation, gate-drive characterization, and small-signal-on-DC-rail measurements, the integrated functions consolidate a multi-instrument workflow into one bench unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — FFT to 1 Mpts\u003c\/h3\u003e\n\u003cp\u003eFrequency-domain analysis with peak detection, markers, and waterfall display — up to 1 Mpts FFT length. Identify harmonics, clock spurs, switching-frequency content, and EMI contributions without switching to a separate spectrum analyzer or exporting waveform data to PC software.\u003c\/p\u003e\n\u003cp\u003eThe same trace that captured a glitch in the time domain immediately reveals its spectral character on the FFT — useful for chasing down EMI sources during pre-compliance work, or for distinguishing switching-supply harmonics from coupled noise on adjacent rails.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Spectrum-Analyzer.png\" alt=\"Built-in FFT spectrum analyzer up to 1 Mpts\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBuilt-in FFT spectrum analyzer for harmonics and EMI investigation\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Spectrum-Analyzer.png\" alt=\"Built-in FFT spectrum analyzer up to 1 Mpts\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBuilt-in FFT spectrum analyzer for harmonics and EMI investigation\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eMixed-Signal Debugging — 16 Optional Digital Channels\u003c\/h3\u003e\n\u003cp\u003e16 optional digital channels add mixed-signal debugging via the UT-M26 logic probe pod. The digital traces display alongside analog channels with full time correlation — see I²C bus traffic and analog ADC output on the same time axis, or watch a control firmware state machine drive the gate signals on a switching power stage.\u003c\/p\u003e\n\u003cp\u003eTime-correlated mixed-signal views are essential for debugging the boundary between firmware and analog hardware. A timing-violation that's invisible on either domain alone often becomes obvious when you can see the digital command and the analog response on the same trace.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e56 Automated Measurements with Statistics\u003c\/h3\u003e\n\u003cp\u003e56 automated measurements cover time, voltage, frequency, and power-quality parameters with statistical analysis (min, max, mean, standard deviation) and trend graphs over long captures. For QA work and bench characterization, the statistical view is more useful than the instantaneous reading — it tells you whether a parameter is drifting, jittering, or holding steady.\u003c\/p\u003e\n\u003cp\u003ePass\/fail mask testing applies user-defined tolerance bands across captured waveforms — useful for rapid go\/no-go testing during bring-up, or for validating board-to-board consistency in small-volume production.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eTouch UI and Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe 7-inch 1024×600 capacitive touchscreen supports pinch-to-zoom, drag, and gesture navigation across waveforms, menus, and measurement readouts. For students and lab newcomers, the touch interface lowers the barrier to advanced features that are buried behind menu trees on older instruments.\u003c\/p\u003e\n\u003cp\u003eConnectivity covers USB Host, USB Device, LAN, AUX Out, and HDMI. The HDMI output drives an external display for classroom demonstration, and LAN connectivity integrates the instrument into automated test scripts and remote-access workflows.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D Engineer (Embedded \/ Hardware Design)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmbedded Systems Prototyping\u003c\/strong\u003e — Mixed-signal debug for microcontroller boards, sensor interfaces, and low-power IoT designs. The 12-bit ADC reveals sensor-output detail that 8-bit scopes flatten into noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed-Signal Debug\u003c\/strong\u003e — Time-correlated analog and digital views with the optional UT-M26 logic pod. Track firmware state machines against analog responses on the same trace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Investigation\u003c\/strong\u003e — All standard embedded protocols included; no license fees for automotive (CAN, CAN-FD, LIN), industrial (RS-422\/485), or audio buses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Integrity Spot Checks\u003c\/strong\u003e — FFT analysis identifies harmonics, clock spurs, and EMI sources without switching to a separate spectrum analyzer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEducation (Teaching Labs, Trade Schools, Community Colleges)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Station Teaching Labs\u003c\/strong\u003e — Twelve-bit resolution and full protocol coverage in a value-tier instrument lets you fit professional measurement capability into a curriculum-grade station budget.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTouchscreen UI Lowers Operator Barrier\u003c\/strong\u003e — Pinch-to-zoom and gesture navigation are familiar from consumer devices; students focus on the measurement, not the menu structure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSame Platform Across Course Levels\u003c\/strong\u003e — Beginning students use basic edge triggering; advanced students access protocol decode, FFT, and power-quality measurements on the same instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHDMI Output for Classroom Display\u003c\/strong\u003e — Drive an external monitor or projector for classroom demonstration of waveform examples.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories \u0026amp; In the Box\u003c\/h2\u003e\n\u003ch3\u003eIncluded with the Instrument\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO1154HD oscilloscope\u003c\/li\u003e\n\u003cli\u003e4 × passive probes (1:1 \/ 10:1 switchable, bandwidth matched to instrument)\u003c\/li\u003e\n\u003cli\u003eUSB cable (USB-A to USB-B)\u003c\/li\u003e\n\u003cli\u003ePower cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eQuick-start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUT-M26 — 16-channel logic probe pod for mixed-signal debugging\u003c\/li\u003e\n\u003cli\u003e\nUT-P07A — 500 MHz passive probe for higher-bandwidth applications\u003c\/li\u003e\n\u003cli\u003e\nUT-P20, UT-P21, UT-V23 — high-voltage passive probes\u003c\/li\u003e\n\u003cli\u003e\nUT-P30, UT-P31, UT-P32, UT-P33 — differential probes for floating measurements\u003c\/li\u003e\n\u003cli\u003e\nUT-P40, UT-P41, UT-P42, UT-P43, UT-P44 — current probes for power-stage and switching-loss measurement\u003c\/li\u003e\n\u003cli\u003e\nUT-ISOT — isolation transformer for safe line-powered measurements\u003c\/li\u003e\n\u003cli\u003e\nUT-M13X — oscilloscope demo board for protocol decoding practice and curriculum modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed an integrated signal generator? See the MSO1154HD-S for the same platform with a 25 MHz AWG and Bode plot analysis added. Need 250 MHz bandwidth for power-electronics work? See the MSO1254HD.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat protocols are included with the MSO1154HD?\u003c\/p\u003e\n\u003cp\u003eRS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio decoding are included standard at no additional cost. All supported protocols are available out of the box — no optional licenses required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the advantage of native 12-bit resolution?\u003c\/p\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical levels compared to 256 for an 8-bit scope — sixteen times greater detail. This reveals small signals riding on large ones, reduces quantization noise, and improves measurement accuracy on low-amplitude signals like power-supply ripple, sensor outputs, and precision analog circuits. R12™ holds the 12-bit resolution at the full bandwidth and sample rate, with no ERES averaging or sample-rate trade-off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I add digital channels for mixed-signal debugging?\u003c\/p\u003e\n\u003cp\u003eYes. The UT-M26 logic probe pod adds 16 digital channels for time-correlated analog and digital views.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes this model include a signal generator?\u003c\/p\u003e\n\u003cp\u003eNo. For an integrated 1-channel 25 MHz AWG with Bode plot analysis, see the MSO1154HD-S.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow does the MSO1154HD compare to the higher-bandwidth UPO2000HD or MSO3000HD scopes?\u003c\/p\u003e\n\u003cp\u003eThe MSO1000HD platform shares the same R12™ 12-bit ADC architecture, Ultra Phosphor 3.0 acquisition, and standard-included protocol decoding as the UPO2000HD and MSO3000HD families. The differences are bandwidth (150–250 MHz here vs 100–500 MHz on UPO2000HD and 350–1000 MHz on MSO3000HD), capture rate (1,000,000 wfms\/s here vs 1,500,000 wfms\/s on MSO3000HD), and the front-panel form factor. For embedded prototyping and mid-tier power-electronics work, the MSO1000HD platform delivers the same architectural advantages at a lower price point.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the firmware field-upgradable?\u003c\/p\u003e\n\u003cp\u003eYes. Firmware updates are free over the product's lifetime and install via USB drive or LAN transfer.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003ePart of the MSO1000HD oscilloscope series. See the series page to compare bandwidth and channel options across the lineup.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Analog + 16 Optional Digital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Mpts per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000 wfms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-inch capacitive touchscreen, 1024×600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, video, runt, slope, zone, setup\/hold, and more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, Audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In FFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — up to 1 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 with statistics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo (available on -S models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBode Plot Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo (available on -S models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional 16-channel via UT-M26 pod\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host \/ USB Device \/ LAN \/ AUX Out \/ HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=111\"\u003eMSO1154HD Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":52275020693802,"sku":"181100300118X","price":691.0,"currency_code":"USD","in_stock":true}]}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/7103\/3642\/collections\/UT8804E_3_sq.jpg?v=1787007336","url":"https:\/\/equipmentleader.com\/collections\/uni-trend.oembed?page=2","provider":"Equipment Leader","version":"1.0","type":"link"}